Cargando…
Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
BACKGROUND: The purpose of the study was to evaluate the dosimetry of the Halcyon in prophylactic cranial irradiation (PCI) with volumetric modulated arc therapy (VMAT) and hippocampal-sparing for small cell lung cancer (SCLC). METHODS: Five VMAT plans were designed on CT images of 15 patients diagn...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10028073/ https://www.ncbi.nlm.nih.gov/pubmed/36959800 http://dx.doi.org/10.3389/fonc.2023.993809 |
_version_ | 1784909860249272320 |
---|---|
author | Sun, Tao Lin, Xiutong Li, Kuo Qiu, Qingtao Duan, Jinghao Zhang, Guifang Yin, Yong |
author_facet | Sun, Tao Lin, Xiutong Li, Kuo Qiu, Qingtao Duan, Jinghao Zhang, Guifang Yin, Yong |
author_sort | Sun, Tao |
collection | PubMed |
description | BACKGROUND: The purpose of the study was to evaluate the dosimetry of the Halcyon in prophylactic cranial irradiation (PCI) with volumetric modulated arc therapy (VMAT) and hippocampal-sparing for small cell lung cancer (SCLC). METHODS: Five VMAT plans were designed on CT images of 15 patients diagnosed with SCLC and received PCI. Three plans with two full arcs were generated on the Trilogy and the TrueBeam accelerators, and flattening filter (FF) and flattening filter free (FFF) modes were used on TrueBeam. Two Halcyon plans with two and three full arcs were generated, referred to as H-2A and H-3A, respectively. The prescription dose was 25 Gy in 2.5-Gy fractions. The dose limit for hippocampus were D(100) ≤ 9Gy and D(max) ≤ 16Gy. The Wilcoxon matched-paired signed-rank test was used to evaluate the significance of the observed differences between the five plans. RESULTS: H-2A plans significantly increased the D(2) of PTV, and H-3A plans showed comparable or even better target dosimetry (better conformity) compared to the three plans on C-arm accelerators. Compared to T and TB plans, the two Halcyon plans significantly reduced the D(100) and mean doses of bilateral hippocampus, the mean doses of eyeballs, and the maximum doses of lenses. D(100) of hippocampus was reduced in TrueBeam plans comparing to Trilogy plans. The FFF plans on TrueBeam also represented advantages in D(mean) and D(100) of hippocampas, D(mean) and D(max) of eyeballs, and the D(max) of lenses compared to FF plans. Halcyon plans and TrueBeam plans with FFF mode increased the MUs compared to FF plans. Comparing to H-2A, the H-3A plans exhibited additional dosimetric advantages, including D(2), CI and HI of PTV, as well as the maximum and mean doses of hippocampus and eyeballs, and the maximum doses of optic nerves and brainstem. The two Halcyon plans significantly reduced the delivery time and showed the higher gamma passing rate than the three plans of C-arm accelerators. CONCLUSIONS: Compared with the C-arm accelerators, the dose of hippocampus and the delivery times on Halcyon are relatively significantly reduced for hippocampal-sparing PCI. Three arcs are recommended for VMAT plans with the Halcyon in hippocampal-sparing PCI. |
format | Online Article Text |
id | pubmed-10028073 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100280732023-03-22 Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators Sun, Tao Lin, Xiutong Li, Kuo Qiu, Qingtao Duan, Jinghao Zhang, Guifang Yin, Yong Front Oncol Oncology BACKGROUND: The purpose of the study was to evaluate the dosimetry of the Halcyon in prophylactic cranial irradiation (PCI) with volumetric modulated arc therapy (VMAT) and hippocampal-sparing for small cell lung cancer (SCLC). METHODS: Five VMAT plans were designed on CT images of 15 patients diagnosed with SCLC and received PCI. Three plans with two full arcs were generated on the Trilogy and the TrueBeam accelerators, and flattening filter (FF) and flattening filter free (FFF) modes were used on TrueBeam. Two Halcyon plans with two and three full arcs were generated, referred to as H-2A and H-3A, respectively. The prescription dose was 25 Gy in 2.5-Gy fractions. The dose limit for hippocampus were D(100) ≤ 9Gy and D(max) ≤ 16Gy. The Wilcoxon matched-paired signed-rank test was used to evaluate the significance of the observed differences between the five plans. RESULTS: H-2A plans significantly increased the D(2) of PTV, and H-3A plans showed comparable or even better target dosimetry (better conformity) compared to the three plans on C-arm accelerators. Compared to T and TB plans, the two Halcyon plans significantly reduced the D(100) and mean doses of bilateral hippocampus, the mean doses of eyeballs, and the maximum doses of lenses. D(100) of hippocampus was reduced in TrueBeam plans comparing to Trilogy plans. The FFF plans on TrueBeam also represented advantages in D(mean) and D(100) of hippocampas, D(mean) and D(max) of eyeballs, and the D(max) of lenses compared to FF plans. Halcyon plans and TrueBeam plans with FFF mode increased the MUs compared to FF plans. Comparing to H-2A, the H-3A plans exhibited additional dosimetric advantages, including D(2), CI and HI of PTV, as well as the maximum and mean doses of hippocampus and eyeballs, and the maximum doses of optic nerves and brainstem. The two Halcyon plans significantly reduced the delivery time and showed the higher gamma passing rate than the three plans of C-arm accelerators. CONCLUSIONS: Compared with the C-arm accelerators, the dose of hippocampus and the delivery times on Halcyon are relatively significantly reduced for hippocampal-sparing PCI. Three arcs are recommended for VMAT plans with the Halcyon in hippocampal-sparing PCI. Frontiers Media S.A. 2023-03-07 /pmc/articles/PMC10028073/ /pubmed/36959800 http://dx.doi.org/10.3389/fonc.2023.993809 Text en Copyright © 2023 Sun, Lin, Li, Qiu, Duan, Zhang and Yin https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Sun, Tao Lin, Xiutong Li, Kuo Qiu, Qingtao Duan, Jinghao Zhang, Guifang Yin, Yong Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators |
title | Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators |
title_full | Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators |
title_fullStr | Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators |
title_full_unstemmed | Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators |
title_short | Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators |
title_sort | volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: planning comparison of halcyon and c-arm accelerators |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10028073/ https://www.ncbi.nlm.nih.gov/pubmed/36959800 http://dx.doi.org/10.3389/fonc.2023.993809 |
work_keys_str_mv | AT suntao volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators AT linxiutong volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators AT likuo volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators AT qiuqingtao volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators AT duanjinghao volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators AT zhangguifang volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators AT yinyong volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators |