Cargando…

Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators

BACKGROUND: The purpose of the study was to evaluate the dosimetry of the Halcyon in prophylactic cranial irradiation (PCI) with volumetric modulated arc therapy (VMAT) and hippocampal-sparing for small cell lung cancer (SCLC). METHODS: Five VMAT plans were designed on CT images of 15 patients diagn...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Tao, Lin, Xiutong, Li, Kuo, Qiu, Qingtao, Duan, Jinghao, Zhang, Guifang, Yin, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10028073/
https://www.ncbi.nlm.nih.gov/pubmed/36959800
http://dx.doi.org/10.3389/fonc.2023.993809
_version_ 1784909860249272320
author Sun, Tao
Lin, Xiutong
Li, Kuo
Qiu, Qingtao
Duan, Jinghao
Zhang, Guifang
Yin, Yong
author_facet Sun, Tao
Lin, Xiutong
Li, Kuo
Qiu, Qingtao
Duan, Jinghao
Zhang, Guifang
Yin, Yong
author_sort Sun, Tao
collection PubMed
description BACKGROUND: The purpose of the study was to evaluate the dosimetry of the Halcyon in prophylactic cranial irradiation (PCI) with volumetric modulated arc therapy (VMAT) and hippocampal-sparing for small cell lung cancer (SCLC). METHODS: Five VMAT plans were designed on CT images of 15 patients diagnosed with SCLC and received PCI. Three plans with two full arcs were generated on the Trilogy and the TrueBeam accelerators, and flattening filter (FF) and flattening filter free (FFF) modes were used on TrueBeam. Two Halcyon plans with two and three full arcs were generated, referred to as H-2A and H-3A, respectively. The prescription dose was 25 Gy in 2.5-Gy fractions. The dose limit for hippocampus were D(100) ≤ 9Gy and D(max) ≤ 16Gy. The Wilcoxon matched-paired signed-rank test was used to evaluate the significance of the observed differences between the five plans. RESULTS: H-2A plans significantly increased the D(2) of PTV, and H-3A plans showed comparable or even better target dosimetry (better conformity) compared to the three plans on C-arm accelerators. Compared to T and TB plans, the two Halcyon plans significantly reduced the D(100) and mean doses of bilateral hippocampus, the mean doses of eyeballs, and the maximum doses of lenses. D(100) of hippocampus was reduced in TrueBeam plans comparing to Trilogy plans. The FFF plans on TrueBeam also represented advantages in D(mean) and D(100) of hippocampas, D(mean) and D(max) of eyeballs, and the D(max) of lenses compared to FF plans. Halcyon plans and TrueBeam plans with FFF mode increased the MUs compared to FF plans. Comparing to H-2A, the H-3A plans exhibited additional dosimetric advantages, including D(2), CI and HI of PTV, as well as the maximum and mean doses of hippocampus and eyeballs, and the maximum doses of optic nerves and brainstem. The two Halcyon plans significantly reduced the delivery time and showed the higher gamma passing rate than the three plans of C-arm accelerators. CONCLUSIONS: Compared with the C-arm accelerators, the dose of hippocampus and the delivery times on Halcyon are relatively significantly reduced for hippocampal-sparing PCI. Three arcs are recommended for VMAT plans with the Halcyon in hippocampal-sparing PCI.
format Online
Article
Text
id pubmed-10028073
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-100280732023-03-22 Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators Sun, Tao Lin, Xiutong Li, Kuo Qiu, Qingtao Duan, Jinghao Zhang, Guifang Yin, Yong Front Oncol Oncology BACKGROUND: The purpose of the study was to evaluate the dosimetry of the Halcyon in prophylactic cranial irradiation (PCI) with volumetric modulated arc therapy (VMAT) and hippocampal-sparing for small cell lung cancer (SCLC). METHODS: Five VMAT plans were designed on CT images of 15 patients diagnosed with SCLC and received PCI. Three plans with two full arcs were generated on the Trilogy and the TrueBeam accelerators, and flattening filter (FF) and flattening filter free (FFF) modes were used on TrueBeam. Two Halcyon plans with two and three full arcs were generated, referred to as H-2A and H-3A, respectively. The prescription dose was 25 Gy in 2.5-Gy fractions. The dose limit for hippocampus were D(100) ≤ 9Gy and D(max) ≤ 16Gy. The Wilcoxon matched-paired signed-rank test was used to evaluate the significance of the observed differences between the five plans. RESULTS: H-2A plans significantly increased the D(2) of PTV, and H-3A plans showed comparable or even better target dosimetry (better conformity) compared to the three plans on C-arm accelerators. Compared to T and TB plans, the two Halcyon plans significantly reduced the D(100) and mean doses of bilateral hippocampus, the mean doses of eyeballs, and the maximum doses of lenses. D(100) of hippocampus was reduced in TrueBeam plans comparing to Trilogy plans. The FFF plans on TrueBeam also represented advantages in D(mean) and D(100) of hippocampas, D(mean) and D(max) of eyeballs, and the D(max) of lenses compared to FF plans. Halcyon plans and TrueBeam plans with FFF mode increased the MUs compared to FF plans. Comparing to H-2A, the H-3A plans exhibited additional dosimetric advantages, including D(2), CI and HI of PTV, as well as the maximum and mean doses of hippocampus and eyeballs, and the maximum doses of optic nerves and brainstem. The two Halcyon plans significantly reduced the delivery time and showed the higher gamma passing rate than the three plans of C-arm accelerators. CONCLUSIONS: Compared with the C-arm accelerators, the dose of hippocampus and the delivery times on Halcyon are relatively significantly reduced for hippocampal-sparing PCI. Three arcs are recommended for VMAT plans with the Halcyon in hippocampal-sparing PCI. Frontiers Media S.A. 2023-03-07 /pmc/articles/PMC10028073/ /pubmed/36959800 http://dx.doi.org/10.3389/fonc.2023.993809 Text en Copyright © 2023 Sun, Lin, Li, Qiu, Duan, Zhang and Yin https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Sun, Tao
Lin, Xiutong
Li, Kuo
Qiu, Qingtao
Duan, Jinghao
Zhang, Guifang
Yin, Yong
Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
title Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
title_full Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
title_fullStr Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
title_full_unstemmed Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
title_short Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
title_sort volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: planning comparison of halcyon and c-arm accelerators
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10028073/
https://www.ncbi.nlm.nih.gov/pubmed/36959800
http://dx.doi.org/10.3389/fonc.2023.993809
work_keys_str_mv AT suntao volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators
AT linxiutong volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators
AT likuo volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators
AT qiuqingtao volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators
AT duanjinghao volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators
AT zhangguifang volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators
AT yinyong volumetricmodulatedarctherapyforhippocampalsparingprophylacticcranialirradiationplanningcomparisonofhalcyonandcarmaccelerators