Cargando…

Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement

BACKGROUND: This study aimed to evaluate the safety and efficacy of portal vein puncture with a new guidance system using double C-arm digital subtraction angiography (DSA) during transjugular intrahepatic portosystemic shunt (TIPS) placement. MATERIAL/METHODS: The procedure details of TIPS placemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Bai, Xiao, Ma, Ping, Tan, Junjie, Li, Yong, He, Xu, Huang, Jianwen, An, Tao, Wang, Chunyan, Li, Jihua, Xu, Weiguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10029320/
https://www.ncbi.nlm.nih.gov/pubmed/36922715
http://dx.doi.org/10.12659/MSM.938912
_version_ 1784910116828479488
author Bai, Xiao
Ma, Ping
Tan, Junjie
Li, Yong
He, Xu
Huang, Jianwen
An, Tao
Wang, Chunyan
Li, Jihua
Xu, Weiguo
author_facet Bai, Xiao
Ma, Ping
Tan, Junjie
Li, Yong
He, Xu
Huang, Jianwen
An, Tao
Wang, Chunyan
Li, Jihua
Xu, Weiguo
author_sort Bai, Xiao
collection PubMed
description BACKGROUND: This study aimed to evaluate the safety and efficacy of portal vein puncture with a new guidance system using double C-arm digital subtraction angiography (DSA) during transjugular intrahepatic portosystemic shunt (TIPS) placement. MATERIAL/METHODS: The procedure details of TIPS placements performed on 39 patients in our center between January and December 2021 were retrospectively analyzed. The procedure was performed under double C-arm DSA guidance (study group) and C-arm DSA (control group) in 18 and 21 patients, respectively. We analyzed the procedure’s technical success, duration of the overall procedure, portal vein puncture, fluoroscopy, radiation exposure, complications, and mortality and morbidity rates 30 days after the procedure. RESULTS: TIPS placement was performed successfully in all patients. The mean portal vein puncture time in the study group (9±5.7 min) was significantly shorter than in the control group (33±14.9 min, p=0.02). The complete mean dose area product of the procedure showed no significant differences (study group, 126±53 Gy/cm(2); control group. 142±66 Gy/cm(2); p=0.42). The intraprocedural complication rates were 0% and 19% in the study and control groups, respectively (p=0.04). The 30-day post-procedural mortality rate in the control group was 4.8% (1/21), with no deaths from technical complications. CONCLUSIONS: Double C-arm DSA guidance is a safe and effective method to assist TIPS placement. This approach may result in shorter portal vein puncture time and lower intraprocedural complication rates.
format Online
Article
Text
id pubmed-10029320
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-100293202023-03-22 Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement Bai, Xiao Ma, Ping Tan, Junjie Li, Yong He, Xu Huang, Jianwen An, Tao Wang, Chunyan Li, Jihua Xu, Weiguo Med Sci Monit Clinical Research BACKGROUND: This study aimed to evaluate the safety and efficacy of portal vein puncture with a new guidance system using double C-arm digital subtraction angiography (DSA) during transjugular intrahepatic portosystemic shunt (TIPS) placement. MATERIAL/METHODS: The procedure details of TIPS placements performed on 39 patients in our center between January and December 2021 were retrospectively analyzed. The procedure was performed under double C-arm DSA guidance (study group) and C-arm DSA (control group) in 18 and 21 patients, respectively. We analyzed the procedure’s technical success, duration of the overall procedure, portal vein puncture, fluoroscopy, radiation exposure, complications, and mortality and morbidity rates 30 days after the procedure. RESULTS: TIPS placement was performed successfully in all patients. The mean portal vein puncture time in the study group (9±5.7 min) was significantly shorter than in the control group (33±14.9 min, p=0.02). The complete mean dose area product of the procedure showed no significant differences (study group, 126±53 Gy/cm(2); control group. 142±66 Gy/cm(2); p=0.42). The intraprocedural complication rates were 0% and 19% in the study and control groups, respectively (p=0.04). The 30-day post-procedural mortality rate in the control group was 4.8% (1/21), with no deaths from technical complications. CONCLUSIONS: Double C-arm DSA guidance is a safe and effective method to assist TIPS placement. This approach may result in shorter portal vein puncture time and lower intraprocedural complication rates. International Scientific Literature, Inc. 2023-03-16 /pmc/articles/PMC10029320/ /pubmed/36922715 http://dx.doi.org/10.12659/MSM.938912 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Bai, Xiao
Ma, Ping
Tan, Junjie
Li, Yong
He, Xu
Huang, Jianwen
An, Tao
Wang, Chunyan
Li, Jihua
Xu, Weiguo
Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement
title Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement
title_full Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement
title_fullStr Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement
title_full_unstemmed Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement
title_short Double C-Arm Digital Subtraction Angiography Guidance During Transjugular Intrahepatic Portosystemic Shunt Placement
title_sort double c-arm digital subtraction angiography guidance during transjugular intrahepatic portosystemic shunt placement
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10029320/
https://www.ncbi.nlm.nih.gov/pubmed/36922715
http://dx.doi.org/10.12659/MSM.938912
work_keys_str_mv AT baixiao doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT maping doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT tanjunjie doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT liyong doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT hexu doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT huangjianwen doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT antao doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT wangchunyan doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT lijihua doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement
AT xuweiguo doublecarmdigitalsubtractionangiographyguidanceduringtransjugularintrahepaticportosystemicshuntplacement