Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from...

Descripción completa

Detalles Bibliográficos
Autores principales: Hillebrand, Arjan, Holmes, Niall, Sijsma, Ndedi, O’Neill, George C., Tierney, Tim M., Liberton, Niels, Stam, Anine H., van Klink, Nicole, Stam, Cornelis J., Bowtell, Richard, Brookes, Matthew J., Barnes, Gareth R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10030968/
https://www.ncbi.nlm.nih.gov/pubmed/36944674
http://dx.doi.org/10.1038/s41598-023-31111-y
_version_ 1784910495149457408
author Hillebrand, Arjan
Holmes, Niall
Sijsma, Ndedi
O’Neill, George C.
Tierney, Tim M.
Liberton, Niels
Stam, Anine H.
van Klink, Nicole
Stam, Cornelis J.
Bowtell, Richard
Brookes, Matthew J.
Barnes, Gareth R.
author_facet Hillebrand, Arjan
Holmes, Niall
Sijsma, Ndedi
O’Neill, George C.
Tierney, Tim M.
Liberton, Niels
Stam, Anine H.
van Klink, Nicole
Stam, Cornelis J.
Bowtell, Richard
Brookes, Matthew J.
Barnes, Gareth R.
author_sort Hillebrand, Arjan
collection PubMed
description Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance and/or logistical considerations. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and enabling recordings during seizures. We aimed to demonstrate the performance of OPMs in a clinical population. Seven patients with challenging cases of epilepsy underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system: three adults with known deep or weak (low SNR) sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures. The consistency of the recorded IEDs across the two systems was assessed. In one patient the OPMs detected IEDs that were not found with the SQUID-system, and in two patients no IEDs were found with either system. For the other patients the OPM data were remarkably consistent with the data from the cryogenic system, noting that these were recorded in different sessions, with comparable SNRs and IED-yields overall. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. The relatively affordable technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure.
format Online
Article
Text
id pubmed-10030968
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-100309682023-03-23 Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers Hillebrand, Arjan Holmes, Niall Sijsma, Ndedi O’Neill, George C. Tierney, Tim M. Liberton, Niels Stam, Anine H. van Klink, Nicole Stam, Cornelis J. Bowtell, Richard Brookes, Matthew J. Barnes, Gareth R. Sci Rep Article Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance and/or logistical considerations. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and enabling recordings during seizures. We aimed to demonstrate the performance of OPMs in a clinical population. Seven patients with challenging cases of epilepsy underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system: three adults with known deep or weak (low SNR) sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures. The consistency of the recorded IEDs across the two systems was assessed. In one patient the OPMs detected IEDs that were not found with the SQUID-system, and in two patients no IEDs were found with either system. For the other patients the OPM data were remarkably consistent with the data from the cryogenic system, noting that these were recorded in different sessions, with comparable SNRs and IED-yields overall. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. The relatively affordable technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure. Nature Publishing Group UK 2023-03-21 /pmc/articles/PMC10030968/ /pubmed/36944674 http://dx.doi.org/10.1038/s41598-023-31111-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Hillebrand, Arjan
Holmes, Niall
Sijsma, Ndedi
O’Neill, George C.
Tierney, Tim M.
Liberton, Niels
Stam, Anine H.
van Klink, Nicole
Stam, Cornelis J.
Bowtell, Richard
Brookes, Matthew J.
Barnes, Gareth R.
Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
title Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
title_full Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
title_fullStr Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
title_full_unstemmed Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
title_short Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
title_sort non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10030968/
https://www.ncbi.nlm.nih.gov/pubmed/36944674
http://dx.doi.org/10.1038/s41598-023-31111-y
work_keys_str_mv AT hillebrandarjan noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT holmesniall noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT sijsmandedi noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT oneillgeorgec noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT tierneytimm noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT libertonniels noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT stamanineh noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT vanklinknicole noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT stamcornelisj noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT bowtellrichard noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT brookesmatthewj noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers
AT barnesgarethr noninvasivemeasurementsofictalandinterictalepileptiformactivityusingopticallypumpedmagnetometers