Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans

BACKGROUND AND OBJECTIVES: In medical imaging, a limited number of trained deep learning algorithms have been externally validated and released publicly. We hypothesized that a deep learning algorithm can be trained to identify and localize subarachnoid hemorrhage (SAH) on head computed tomography (...

Descripción completa

Detalles Bibliográficos
Autores principales: Thanellas, Antonios, Peura, Heikki, Lavinto, Mikko, Ruokola, Tomi, Vieli, Moira, Staartjes, Victor E., Winklhofer, Sebastian, Serra, Carlo, Regli, Luca, Korja, Miikka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10033159/
https://www.ncbi.nlm.nih.gov/pubmed/36639236
http://dx.doi.org/10.1212/WNL.0000000000201710
_version_ 1784910952758509568
author Thanellas, Antonios
Peura, Heikki
Lavinto, Mikko
Ruokola, Tomi
Vieli, Moira
Staartjes, Victor E.
Winklhofer, Sebastian
Serra, Carlo
Regli, Luca
Korja, Miikka
author_facet Thanellas, Antonios
Peura, Heikki
Lavinto, Mikko
Ruokola, Tomi
Vieli, Moira
Staartjes, Victor E.
Winklhofer, Sebastian
Serra, Carlo
Regli, Luca
Korja, Miikka
author_sort Thanellas, Antonios
collection PubMed
description BACKGROUND AND OBJECTIVES: In medical imaging, a limited number of trained deep learning algorithms have been externally validated and released publicly. We hypothesized that a deep learning algorithm can be trained to identify and localize subarachnoid hemorrhage (SAH) on head computed tomography (CT) scans and that the trained model performs satisfactorily when tested using external and real-world data. METHODS: We used noncontrast head CT images of patients admitted to Helsinki University Hospital between 2012 and 2017. We manually segmented (i.e., delineated) SAH on 90 head CT scans and used the segmented CT scans together with 22 negative (no SAH) control CT scans in training an open-source convolutional neural network (U-Net) to identify and localize SAH. We then tested the performance of the trained algorithm by using external data sets (137 SAH and 1,242 control cases) collected in 2 foreign countries and also by creating a data set of consecutive emergency head CT scans (8 SAH and 511 control cases) performed during on-call hours in 5 different domestic hospitals in September 2021. We assessed the algorithm's capability to identify SAH by calculating patient- and slice-level performance metrics, such as sensitivity and specificity. RESULTS: In the external validation set of 1,379 cases, the algorithm identified 136 of 137 SAH cases correctly (sensitivity 99.3% and specificity 63.2%). Of the 49,064 axial head CT slices, the algorithm identified and localized SAH in 1845 of 2,110 slices with SAH (sensitivity 87.4% and specificity 95.3%). Of 519 consecutive emergency head CT scans imaged in September 2021, the algorithm identified all 8 SAH cases correctly (sensitivity 100.0% and specificity 75.3%). The slice-level (27,167 axial slices in total) sensitivity and specificity were 87.3% and 98.8%, respectively, as the algorithm identified and localized SAH in 58 of 77 slices with SAH. The performance of the algorithm can be tested on through a web service. DISCUSSION: We show that the shared algorithm identifies SAH cases with a high sensitivity and that the slice-level specificity is high. In addition to openly sharing a high-performing deep learning algorithm, our work presents infrequently used approaches in designing, training, testing, and reporting deep learning algorithms developed for medical imaging diagnostics. CLASSIFICATION OF EVIDENCE: This study provides Class III evidence that a deep learning algorithm correctly identifies the presence of subarachnoid hemorrhage on CT scan.
format Online
Article
Text
id pubmed-10033159
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-100331592023-03-23 Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans Thanellas, Antonios Peura, Heikki Lavinto, Mikko Ruokola, Tomi Vieli, Moira Staartjes, Victor E. Winklhofer, Sebastian Serra, Carlo Regli, Luca Korja, Miikka Neurology Research Article BACKGROUND AND OBJECTIVES: In medical imaging, a limited number of trained deep learning algorithms have been externally validated and released publicly. We hypothesized that a deep learning algorithm can be trained to identify and localize subarachnoid hemorrhage (SAH) on head computed tomography (CT) scans and that the trained model performs satisfactorily when tested using external and real-world data. METHODS: We used noncontrast head CT images of patients admitted to Helsinki University Hospital between 2012 and 2017. We manually segmented (i.e., delineated) SAH on 90 head CT scans and used the segmented CT scans together with 22 negative (no SAH) control CT scans in training an open-source convolutional neural network (U-Net) to identify and localize SAH. We then tested the performance of the trained algorithm by using external data sets (137 SAH and 1,242 control cases) collected in 2 foreign countries and also by creating a data set of consecutive emergency head CT scans (8 SAH and 511 control cases) performed during on-call hours in 5 different domestic hospitals in September 2021. We assessed the algorithm's capability to identify SAH by calculating patient- and slice-level performance metrics, such as sensitivity and specificity. RESULTS: In the external validation set of 1,379 cases, the algorithm identified 136 of 137 SAH cases correctly (sensitivity 99.3% and specificity 63.2%). Of the 49,064 axial head CT slices, the algorithm identified and localized SAH in 1845 of 2,110 slices with SAH (sensitivity 87.4% and specificity 95.3%). Of 519 consecutive emergency head CT scans imaged in September 2021, the algorithm identified all 8 SAH cases correctly (sensitivity 100.0% and specificity 75.3%). The slice-level (27,167 axial slices in total) sensitivity and specificity were 87.3% and 98.8%, respectively, as the algorithm identified and localized SAH in 58 of 77 slices with SAH. The performance of the algorithm can be tested on through a web service. DISCUSSION: We show that the shared algorithm identifies SAH cases with a high sensitivity and that the slice-level specificity is high. In addition to openly sharing a high-performing deep learning algorithm, our work presents infrequently used approaches in designing, training, testing, and reporting deep learning algorithms developed for medical imaging diagnostics. CLASSIFICATION OF EVIDENCE: This study provides Class III evidence that a deep learning algorithm correctly identifies the presence of subarachnoid hemorrhage on CT scan. Lippincott Williams & Wilkins 2023-03-21 /pmc/articles/PMC10033159/ /pubmed/36639236 http://dx.doi.org/10.1212/WNL.0000000000201710 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (CC BY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Thanellas, Antonios
Peura, Heikki
Lavinto, Mikko
Ruokola, Tomi
Vieli, Moira
Staartjes, Victor E.
Winklhofer, Sebastian
Serra, Carlo
Regli, Luca
Korja, Miikka
Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans
title Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans
title_full Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans
title_fullStr Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans
title_full_unstemmed Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans
title_short Development and External Validation of a Deep Learning Algorithm to Identify and Localize Subarachnoid Hemorrhage on CT Scans
title_sort development and external validation of a deep learning algorithm to identify and localize subarachnoid hemorrhage on ct scans
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10033159/
https://www.ncbi.nlm.nih.gov/pubmed/36639236
http://dx.doi.org/10.1212/WNL.0000000000201710
work_keys_str_mv AT thanellasantonios developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT peuraheikki developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT lavintomikko developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT ruokolatomi developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT vielimoira developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT staartjesvictore developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT winklhofersebastian developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT serracarlo developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT regliluca developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans
AT korjamiikka developmentandexternalvalidationofadeeplearningalgorithmtoidentifyandlocalizesubarachnoidhemorrhageonctscans