Cargando…

Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy

PURPOSE: Total marrow (and lymphoid) irradiation (TMI-TMLI) is limited by the couch travel range of modern linacs, which forces the treatment delivery to be split into two plans with opposite orientations: a head-first supine upper-body plan, and a feet-first supine lower extremities plan. A specifi...

Descripción completa

Detalles Bibliográficos
Autores principales: Lambri, Nicola, Dei, Damiano, Hernandez, Victor, Castiglioni, Isabella, Clerici, Elena, Crespi, Leonardo, De Philippis, Chiara, Loiacono, Daniele, Navarria, Pierina, Reggiori, Giacomo, Rusconi, Roberto, Tomatis, Stefano, Bramanti, Stefania, Scorsetti, Marta, Mancosu, Pietro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10033624/
https://www.ncbi.nlm.nih.gov/pubmed/36326856
http://dx.doi.org/10.1007/s00066-022-02014-0
_version_ 1784911032387371008
author Lambri, Nicola
Dei, Damiano
Hernandez, Victor
Castiglioni, Isabella
Clerici, Elena
Crespi, Leonardo
De Philippis, Chiara
Loiacono, Daniele
Navarria, Pierina
Reggiori, Giacomo
Rusconi, Roberto
Tomatis, Stefano
Bramanti, Stefania
Scorsetti, Marta
Mancosu, Pietro
author_facet Lambri, Nicola
Dei, Damiano
Hernandez, Victor
Castiglioni, Isabella
Clerici, Elena
Crespi, Leonardo
De Philippis, Chiara
Loiacono, Daniele
Navarria, Pierina
Reggiori, Giacomo
Rusconi, Roberto
Tomatis, Stefano
Bramanti, Stefania
Scorsetti, Marta
Mancosu, Pietro
author_sort Lambri, Nicola
collection PubMed
description PURPOSE: Total marrow (and lymphoid) irradiation (TMI-TMLI) is limited by the couch travel range of modern linacs, which forces the treatment delivery to be split into two plans with opposite orientations: a head-first supine upper-body plan, and a feet-first supine lower extremities plan. A specific field junction is thus needed to obtain adequate target coverage in the overlap region of the two plans. In this study, an automatic procedure was developed for field junction creation and lower extremities plan optimization. METHODS: Ten patients treated with TMI-TMLI at our institution were selected retrospectively. The planning of the lower extremities was performed automatically. Target volume parameters (CTV_J‑V(98%) > 98%) at the junction region and several dose statistics (D(98%), D(mean), and D(2%)) were compared between automatic and manual plans. The modulation complexity score (MCS) was used to assess plan complexity. RESULTS: The automatic procedure required 60–90 min, depending on the case. All automatic plans achieved clinically acceptable dosimetric results (CTV_J‑V(98%) > 98%), with significant differences found at the junction region, where D(mean) and D(2%) increased on average by 2.4% (p < 0.03) and 3.0% (p < 0.02), respectively. Similar plan complexity was observed (median MCS = 0.12). Since March 2022, the automatic procedure has been introduced in our clinic, reducing the TMI-TMLI simulation-to-delivery schedule by 2 days. CONCLUSION: The developed procedure allowed treatment planning of TMI-TMLI to be streamlined, increasing efficiency and standardization, preventing human errors, while maintaining the dosimetric plan quality and complexity of manual plans. Automated strategies can simplify the future adoption and clinical implementation of TMI-TMLI treatments in new centers. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s00066-022-02014-0) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-10033624
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-100336242023-03-24 Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy Lambri, Nicola Dei, Damiano Hernandez, Victor Castiglioni, Isabella Clerici, Elena Crespi, Leonardo De Philippis, Chiara Loiacono, Daniele Navarria, Pierina Reggiori, Giacomo Rusconi, Roberto Tomatis, Stefano Bramanti, Stefania Scorsetti, Marta Mancosu, Pietro Strahlenther Onkol Original Article PURPOSE: Total marrow (and lymphoid) irradiation (TMI-TMLI) is limited by the couch travel range of modern linacs, which forces the treatment delivery to be split into two plans with opposite orientations: a head-first supine upper-body plan, and a feet-first supine lower extremities plan. A specific field junction is thus needed to obtain adequate target coverage in the overlap region of the two plans. In this study, an automatic procedure was developed for field junction creation and lower extremities plan optimization. METHODS: Ten patients treated with TMI-TMLI at our institution were selected retrospectively. The planning of the lower extremities was performed automatically. Target volume parameters (CTV_J‑V(98%) > 98%) at the junction region and several dose statistics (D(98%), D(mean), and D(2%)) were compared between automatic and manual plans. The modulation complexity score (MCS) was used to assess plan complexity. RESULTS: The automatic procedure required 60–90 min, depending on the case. All automatic plans achieved clinically acceptable dosimetric results (CTV_J‑V(98%) > 98%), with significant differences found at the junction region, where D(mean) and D(2%) increased on average by 2.4% (p < 0.03) and 3.0% (p < 0.02), respectively. Similar plan complexity was observed (median MCS = 0.12). Since March 2022, the automatic procedure has been introduced in our clinic, reducing the TMI-TMLI simulation-to-delivery schedule by 2 days. CONCLUSION: The developed procedure allowed treatment planning of TMI-TMLI to be streamlined, increasing efficiency and standardization, preventing human errors, while maintaining the dosimetric plan quality and complexity of manual plans. Automated strategies can simplify the future adoption and clinical implementation of TMI-TMLI treatments in new centers. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s00066-022-02014-0) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2022-11-03 2023 /pmc/articles/PMC10033624/ /pubmed/36326856 http://dx.doi.org/10.1007/s00066-022-02014-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Lambri, Nicola
Dei, Damiano
Hernandez, Victor
Castiglioni, Isabella
Clerici, Elena
Crespi, Leonardo
De Philippis, Chiara
Loiacono, Daniele
Navarria, Pierina
Reggiori, Giacomo
Rusconi, Roberto
Tomatis, Stefano
Bramanti, Stefania
Scorsetti, Marta
Mancosu, Pietro
Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
title Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
title_full Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
title_fullStr Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
title_full_unstemmed Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
title_short Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
title_sort automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10033624/
https://www.ncbi.nlm.nih.gov/pubmed/36326856
http://dx.doi.org/10.1007/s00066-022-02014-0
work_keys_str_mv AT lambrinicola automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT deidamiano automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT hernandezvictor automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT castiglioniisabella automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT clericielena automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT crespileonardo automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT dephilippischiara automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT loiaconodaniele automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT navarriapierina automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT reggiorigiacomo automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT rusconiroberto automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT tomatisstefano automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT bramantistefania automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT scorsettimarta automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy
AT mancosupietro automaticplanningofthelowerextremitiesfortotalmarrowirradiationusingvolumetricmodulatedarctherapy