Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes
OBJECTIVES: We aimed to evaluate (1) whether sedation analgesia (SA) used during therapeutic hypothermia (TH) was efficient to support the wellbeing of neonates with hypoxic-ischemic encephalopathy, (2) the SA level and its adjustment to clinical pain scores, and (3) the impact of inadequate SA on s...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034099/ https://www.ncbi.nlm.nih.gov/pubmed/36969279 http://dx.doi.org/10.3389/fped.2023.1057724 |
_version_ | 1784911136066371584 |
---|---|
author | Nakhleh-Philippe, Pauline Zores, Claire Stern-Delfils, Amélie Escande, Benoît Astruc, Dominique Severac, François Kuhn, Pierre |
author_facet | Nakhleh-Philippe, Pauline Zores, Claire Stern-Delfils, Amélie Escande, Benoît Astruc, Dominique Severac, François Kuhn, Pierre |
author_sort | Nakhleh-Philippe, Pauline |
collection | PubMed |
description | OBJECTIVES: We aimed to evaluate (1) whether sedation analgesia (SA) used during therapeutic hypothermia (TH) was efficient to support the wellbeing of neonates with hypoxic-ischemic encephalopathy, (2) the SA level and its adjustment to clinical pain scores, and (3) the impact of inadequate SA on short-term neonatal outcomes evaluated at discharge. METHODS: This was an observational retrospective study performed between 2011 and 2018 in two level III centers in Alsace, France. We analyzed the wellbeing of infants by using the COMFORT-Behavior (COMFORT-B) clinical score and SA level during TH, according to which we classified infants into four groups: those with excess SA, adequate SA, lack of SA, and variability of SA. We analyzed the variations in doses of SA and their justification. We also determined the impact of inadequate SA on neonatal outcomes at discharge by multivariate analyses with multinomial regression, with adequate SA as the reference. RESULTS: A total of 110 patients were included, 89 from Strasbourg university hospital and 21 from Mulhouse hospital. The COMFORT-B score was assessed 95.5% of the time. Lack of SA was mainly found on the first day of TH (15/110, 14%). In all, 62 of 110 (57%) infants were in excess of SA over the entire duration of TH. Most dose variations were related to clinical pain scores. Inadequate SA was associated with negative short-term consequences. Infants with excess of SA had a longer duration of mechanical ventilation [mean ratio 1.46, 95% confidence interval (CI), 1.13–1.89, p = 0.005] and higher incidence of abnormal neurological examination at discharge (odds ratio 2.61, 95% CI, 1.10–6.18, p = 0.029) than infants with adequate SA. DISCUSSION: Adequate SA was not easy to achieve during TH. Close and regular monitoring of SA level may help achieve adequate SA. Excess of SA can be harmful for newborns with hypoxic-ischemic encephalopathy who are undergoing TH. |
format | Online Article Text |
id | pubmed-10034099 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100340992023-03-24 Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes Nakhleh-Philippe, Pauline Zores, Claire Stern-Delfils, Amélie Escande, Benoît Astruc, Dominique Severac, François Kuhn, Pierre Front Pediatr Pediatrics OBJECTIVES: We aimed to evaluate (1) whether sedation analgesia (SA) used during therapeutic hypothermia (TH) was efficient to support the wellbeing of neonates with hypoxic-ischemic encephalopathy, (2) the SA level and its adjustment to clinical pain scores, and (3) the impact of inadequate SA on short-term neonatal outcomes evaluated at discharge. METHODS: This was an observational retrospective study performed between 2011 and 2018 in two level III centers in Alsace, France. We analyzed the wellbeing of infants by using the COMFORT-Behavior (COMFORT-B) clinical score and SA level during TH, according to which we classified infants into four groups: those with excess SA, adequate SA, lack of SA, and variability of SA. We analyzed the variations in doses of SA and their justification. We also determined the impact of inadequate SA on neonatal outcomes at discharge by multivariate analyses with multinomial regression, with adequate SA as the reference. RESULTS: A total of 110 patients were included, 89 from Strasbourg university hospital and 21 from Mulhouse hospital. The COMFORT-B score was assessed 95.5% of the time. Lack of SA was mainly found on the first day of TH (15/110, 14%). In all, 62 of 110 (57%) infants were in excess of SA over the entire duration of TH. Most dose variations were related to clinical pain scores. Inadequate SA was associated with negative short-term consequences. Infants with excess of SA had a longer duration of mechanical ventilation [mean ratio 1.46, 95% confidence interval (CI), 1.13–1.89, p = 0.005] and higher incidence of abnormal neurological examination at discharge (odds ratio 2.61, 95% CI, 1.10–6.18, p = 0.029) than infants with adequate SA. DISCUSSION: Adequate SA was not easy to achieve during TH. Close and regular monitoring of SA level may help achieve adequate SA. Excess of SA can be harmful for newborns with hypoxic-ischemic encephalopathy who are undergoing TH. Frontiers Media S.A. 2023-03-09 /pmc/articles/PMC10034099/ /pubmed/36969279 http://dx.doi.org/10.3389/fped.2023.1057724 Text en © 2023 Nakhleh-Philippe, Zores, Stern-Delfils, Escande, Astruc, Severac and Kuhn. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Pediatrics Nakhleh-Philippe, Pauline Zores, Claire Stern-Delfils, Amélie Escande, Benoît Astruc, Dominique Severac, François Kuhn, Pierre Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
title | Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
title_full | Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
title_fullStr | Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
title_full_unstemmed | Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
title_short | Adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
title_sort | adequacy of sedation analgesia to support the comfort of neonates undergoing therapeutic hypothermia and its impact on short-term neonatal outcomes |
topic | Pediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034099/ https://www.ncbi.nlm.nih.gov/pubmed/36969279 http://dx.doi.org/10.3389/fped.2023.1057724 |
work_keys_str_mv | AT nakhlehphilippepauline adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes AT zoresclaire adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes AT sterndelfilsamelie adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes AT escandebenoit adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes AT astrucdominique adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes AT severacfrancois adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes AT kuhnpierre adequacyofsedationanalgesiatosupportthecomfortofneonatesundergoingtherapeutichypothermiaanditsimpactonshorttermneonataloutcomes |