Cargando…

Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats

CASE SERIES SUMMARY: Adrenal tumors are rare in cats and reports of laparoscopic adrenalectomy in cats are limited. This case series describes two cats that underwent laparoscopic adrenalectomy using a Harmonic scalpel for dissection and coagulation. Both surgeries were successful, with minimal hemo...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Rey M, Case, J Brad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034285/
https://www.ncbi.nlm.nih.gov/pubmed/36969148
http://dx.doi.org/10.1177/20551169231159635
_version_ 1784911181405749248
author Zhang, Rey M
Case, J Brad
author_facet Zhang, Rey M
Case, J Brad
author_sort Zhang, Rey M
collection PubMed
description CASE SERIES SUMMARY: Adrenal tumors are rare in cats and reports of laparoscopic adrenalectomy in cats are limited. This case series describes two cats that underwent laparoscopic adrenalectomy using a Harmonic scalpel for dissection and coagulation. Both surgeries were successful, with minimal hemorrhage, smoke production and lateral thermal damage. Vessels were appropriately sealed and surgical times were appropriate. Both cats recovered without complications postoperatively. RELEVANCE AND NOVEL INFORMATION: To our knowledge, this is the first veterinary report to describe the use of the Harmonic scalpel for laparoscopic adrenalectomy as the sole device in cats. Owing to the absence of hemorrhage, there was no indication for irrigation, suction or hemostatics. The Harmonic scalpel is an ultrasonic vessel-sealing device with benefits over conventional electrosurgery, including less lateral thermal damage, less smoke production and improved safety due to the lack of an electrical current. This case report aims to highlight the usefulness of ultrasonic vessel-sealing devices for laparoscopic adrenalectomy in cats.
format Online
Article
Text
id pubmed-10034285
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-100342852023-03-24 Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats Zhang, Rey M Case, J Brad JFMS Open Rep Case Series CASE SERIES SUMMARY: Adrenal tumors are rare in cats and reports of laparoscopic adrenalectomy in cats are limited. This case series describes two cats that underwent laparoscopic adrenalectomy using a Harmonic scalpel for dissection and coagulation. Both surgeries were successful, with minimal hemorrhage, smoke production and lateral thermal damage. Vessels were appropriately sealed and surgical times were appropriate. Both cats recovered without complications postoperatively. RELEVANCE AND NOVEL INFORMATION: To our knowledge, this is the first veterinary report to describe the use of the Harmonic scalpel for laparoscopic adrenalectomy as the sole device in cats. Owing to the absence of hemorrhage, there was no indication for irrigation, suction or hemostatics. The Harmonic scalpel is an ultrasonic vessel-sealing device with benefits over conventional electrosurgery, including less lateral thermal damage, less smoke production and improved safety due to the lack of an electrical current. This case report aims to highlight the usefulness of ultrasonic vessel-sealing devices for laparoscopic adrenalectomy in cats. SAGE Publications 2023-03-22 /pmc/articles/PMC10034285/ /pubmed/36969148 http://dx.doi.org/10.1177/20551169231159635 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Case Series
Zhang, Rey M
Case, J Brad
Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats
title Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats
title_full Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats
title_fullStr Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats
title_full_unstemmed Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats
title_short Use of a Harmonic scalpel for laparoscopic adrenalectomy in two cats
title_sort use of a harmonic scalpel for laparoscopic adrenalectomy in two cats
topic Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034285/
https://www.ncbi.nlm.nih.gov/pubmed/36969148
http://dx.doi.org/10.1177/20551169231159635
work_keys_str_mv AT zhangreym useofaharmonicscalpelforlaparoscopicadrenalectomyintwocats
AT casejbrad useofaharmonicscalpelforlaparoscopicadrenalectomyintwocats