Cargando…
Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer?
PURPOSE: To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients. MATERIAL AND METHODS: Sixty patients with cervical cancer without vaginal involvement were sel...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034727/ https://www.ncbi.nlm.nih.gov/pubmed/36970440 http://dx.doi.org/10.5114/jcb.2023.124399 |
_version_ | 1784911269847891968 |
---|---|
author | Fröhlich, Georgina Vízkeleti, Júlia Nguyen, Anhhong Nhung Polgár, Csaba Takácsi-Nagy, Zoltán Major, Tibor |
author_facet | Fröhlich, Georgina Vízkeleti, Júlia Nguyen, Anhhong Nhung Polgár, Csaba Takácsi-Nagy, Zoltán Major, Tibor |
author_sort | Fröhlich, Georgina |
collection | PubMed |
description | PURPOSE: To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients. MATERIAL AND METHODS: Sixty patients with cervical cancer without vaginal involvement were selected for the study, who received intra-cavitary/interstitial BT. For each patient, two plans with and without active source dwell positions in R/O were created, using the same dose-volume constraints. EQD(2) total doses from external beam and BT of target volumes and organs at risk (OARs) between the competing plans were compared. RESULTS: There was no significant difference in the dose of high-risk clinical target volume (HR-CTV) and gross tumor volume (GTV) between the plans with inactive vs. active R/O. The mean D(98) of intermediate-risk clinical target volume (IR-CTV) was significantly lower with inactive R/O; however, the GEC-ESTRO (EMBRACE II study) and ABS criteria were fulfilled in 96% in both plans. There was no difference in dose homogeneity, but conformity of the plans with inactive R/O was higher. Doses to all OARs were significantly lower in plans without R/O activation. While all the plans without R/O activation fulfilled the recommended dose criteria for OARs, it was less achievable with R/O activation. CONCLUSIONS: Inactivation of R/O applicator results in similar dose coverage of the target volumes with lower doses to all OARs, as activation of R/O in cervix cancer patients when HR-CTV does not extend to R/O applicator. The use of active source positions in R/O shows worse performance regarding the fulfilment of the recommended criteria for OARs. |
format | Online Article Text |
id | pubmed-10034727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-100347272023-03-24 Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? Fröhlich, Georgina Vízkeleti, Júlia Nguyen, Anhhong Nhung Polgár, Csaba Takácsi-Nagy, Zoltán Major, Tibor J Contemp Brachytherapy Original Paper PURPOSE: To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients. MATERIAL AND METHODS: Sixty patients with cervical cancer without vaginal involvement were selected for the study, who received intra-cavitary/interstitial BT. For each patient, two plans with and without active source dwell positions in R/O were created, using the same dose-volume constraints. EQD(2) total doses from external beam and BT of target volumes and organs at risk (OARs) between the competing plans were compared. RESULTS: There was no significant difference in the dose of high-risk clinical target volume (HR-CTV) and gross tumor volume (GTV) between the plans with inactive vs. active R/O. The mean D(98) of intermediate-risk clinical target volume (IR-CTV) was significantly lower with inactive R/O; however, the GEC-ESTRO (EMBRACE II study) and ABS criteria were fulfilled in 96% in both plans. There was no difference in dose homogeneity, but conformity of the plans with inactive R/O was higher. Doses to all OARs were significantly lower in plans without R/O activation. While all the plans without R/O activation fulfilled the recommended dose criteria for OARs, it was less achievable with R/O activation. CONCLUSIONS: Inactivation of R/O applicator results in similar dose coverage of the target volumes with lower doses to all OARs, as activation of R/O in cervix cancer patients when HR-CTV does not extend to R/O applicator. The use of active source positions in R/O shows worse performance regarding the fulfilment of the recommended criteria for OARs. Termedia Publishing House 2023-01-20 2023-02 /pmc/articles/PMC10034727/ /pubmed/36970440 http://dx.doi.org/10.5114/jcb.2023.124399 Text en Copyright © 2023 Termedia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) ) |
spellingShingle | Original Paper Fröhlich, Georgina Vízkeleti, Júlia Nguyen, Anhhong Nhung Polgár, Csaba Takácsi-Nagy, Zoltán Major, Tibor Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
title | Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
title_full | Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
title_fullStr | Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
title_full_unstemmed | Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
title_short | Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
title_sort | are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer? |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10034727/ https://www.ncbi.nlm.nih.gov/pubmed/36970440 http://dx.doi.org/10.5114/jcb.2023.124399 |
work_keys_str_mv | AT frohlichgeorgina areactivedwellpositionsalwaysnecessaryintheringovoidschannelofthecervicalapplicatorintheintracavitaryinterstitialbrachytherapyofcervicalcancer AT vizkeletijulia areactivedwellpositionsalwaysnecessaryintheringovoidschannelofthecervicalapplicatorintheintracavitaryinterstitialbrachytherapyofcervicalcancer AT nguyenanhhongnhung areactivedwellpositionsalwaysnecessaryintheringovoidschannelofthecervicalapplicatorintheintracavitaryinterstitialbrachytherapyofcervicalcancer AT polgarcsaba areactivedwellpositionsalwaysnecessaryintheringovoidschannelofthecervicalapplicatorintheintracavitaryinterstitialbrachytherapyofcervicalcancer AT takacsinagyzoltan areactivedwellpositionsalwaysnecessaryintheringovoidschannelofthecervicalapplicatorintheintracavitaryinterstitialbrachytherapyofcervicalcancer AT majortibor areactivedwellpositionsalwaysnecessaryintheringovoidschannelofthecervicalapplicatorintheintracavitaryinterstitialbrachytherapyofcervicalcancer |