Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor
Human walking reflects the state of human health. Numerous medical studies have been conducted to analyze walking patterns and to diagnose disease progression. However, this process requires expensive equipment and considerable time and manpower. Smartwatches are equipped with gyro sensors to detect...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036010/ https://www.ncbi.nlm.nih.gov/pubmed/36961172 http://dx.doi.org/10.1097/MD.0000000000033267 |
_version_ | 1784911547498233856 |
---|---|
author | Han, Sumin Paul, Rob |
author_facet | Han, Sumin Paul, Rob |
author_sort | Han, Sumin |
collection | PubMed |
description | Human walking reflects the state of human health. Numerous medical studies have been conducted to analyze walking patterns and to diagnose disease progression. However, this process requires expensive equipment and considerable time and manpower. Smartwatches are equipped with gyro sensors to detect human movements and graph-walking patterns. To measure the abnormality in walking using this graph, we developed a smartwatch gait coordination index (SGCI) and examined its usefulness. The phase coordination index was applied to analyze arm movements. Based on previous studies, the phase coordination index formula was applied to graphs obtained from arm movements, showing that arm and leg movements during walking are correlated with each other. To prove this, a smartwatch was worn on the arms and legs of 8 healthy adults and the difference in arm movements was measured. The SGCI values with abnormal walking patterns were compared with the SGCI values obtained during normal walking. In the first experiment, the measured leg SGCI in normal walking averaged 9.002 ± 3.872 and the arm SGCI averaged 9.847 ± 6.115. The movements of both arms and legs showed stable sinusoidal waves. In fact, as a result of performing a paired t test of both exercise phases measured by the strike point using the maximum and minimum values, it was confirmed that the 2 exercises were not statistically different, as it yielded a P value of 0.469 (significance level α = 0.05). The arm SGCI measured after applying the 3 kg weight impairment on 1 leg was 22.167 ± 4.705. It was confirmed that the leg SGCI and 3 kg weight arm SGCI were statistically significant, as it yielded a P value of 0.001 (significance level α = 0.05). The SCGI can be automatically and continuously measured with the gyro sensor of the smartwatch and can be used as an indirect indicator of human walking conditions. |
format | Online Article Text |
id | pubmed-10036010 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-100360102023-03-24 Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor Han, Sumin Paul, Rob Medicine (Baltimore) 6600 Human walking reflects the state of human health. Numerous medical studies have been conducted to analyze walking patterns and to diagnose disease progression. However, this process requires expensive equipment and considerable time and manpower. Smartwatches are equipped with gyro sensors to detect human movements and graph-walking patterns. To measure the abnormality in walking using this graph, we developed a smartwatch gait coordination index (SGCI) and examined its usefulness. The phase coordination index was applied to analyze arm movements. Based on previous studies, the phase coordination index formula was applied to graphs obtained from arm movements, showing that arm and leg movements during walking are correlated with each other. To prove this, a smartwatch was worn on the arms and legs of 8 healthy adults and the difference in arm movements was measured. The SGCI values with abnormal walking patterns were compared with the SGCI values obtained during normal walking. In the first experiment, the measured leg SGCI in normal walking averaged 9.002 ± 3.872 and the arm SGCI averaged 9.847 ± 6.115. The movements of both arms and legs showed stable sinusoidal waves. In fact, as a result of performing a paired t test of both exercise phases measured by the strike point using the maximum and minimum values, it was confirmed that the 2 exercises were not statistically different, as it yielded a P value of 0.469 (significance level α = 0.05). The arm SGCI measured after applying the 3 kg weight impairment on 1 leg was 22.167 ± 4.705. It was confirmed that the leg SGCI and 3 kg weight arm SGCI were statistically significant, as it yielded a P value of 0.001 (significance level α = 0.05). The SCGI can be automatically and continuously measured with the gyro sensor of the smartwatch and can be used as an indirect indicator of human walking conditions. Lippincott Williams & Wilkins 2023-03-24 /pmc/articles/PMC10036010/ /pubmed/36961172 http://dx.doi.org/10.1097/MD.0000000000033267 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | 6600 Han, Sumin Paul, Rob Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor |
title | Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor |
title_full | Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor |
title_fullStr | Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor |
title_full_unstemmed | Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor |
title_short | Smartwatch gait coordination index: New measure for human gait utilizing smartwatch sensor |
title_sort | smartwatch gait coordination index: new measure for human gait utilizing smartwatch sensor |
topic | 6600 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036010/ https://www.ncbi.nlm.nih.gov/pubmed/36961172 http://dx.doi.org/10.1097/MD.0000000000033267 |
work_keys_str_mv | AT hansumin smartwatchgaitcoordinationindexnewmeasureforhumangaitutilizingsmartwatchsensor AT paulrob smartwatchgaitcoordinationindexnewmeasureforhumangaitutilizingsmartwatchsensor |