Cargando…

Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis

Rotating machines are often operated under various operating conditions. However, the characteristics of the data varies with their operating conditions. This article presents the time-series dataset, including vibration, acoustic, temperature, and driving current data of rotating machines under var...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Wonho, Kim, Seong-Hu, Yun, Sung-Hyun, Bae, Jaewoong, Park, Yong-Hwa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036499/
https://www.ncbi.nlm.nih.gov/pubmed/36969976
http://dx.doi.org/10.1016/j.dib.2023.109049
_version_ 1784911668723056640
author Jung, Wonho
Kim, Seong-Hu
Yun, Sung-Hyun
Bae, Jaewoong
Park, Yong-Hwa
author_facet Jung, Wonho
Kim, Seong-Hu
Yun, Sung-Hyun
Bae, Jaewoong
Park, Yong-Hwa
author_sort Jung, Wonho
collection PubMed
description Rotating machines are often operated under various operating conditions. However, the characteristics of the data varies with their operating conditions. This article presents the time-series dataset, including vibration, acoustic, temperature, and driving current data of rotating machines under varying operating conditions. The dataset was acquired using four ceramic shear ICP based accelerometers, one microphone, two thermocouples, and three current transformer (CT) based on the international organization for standardization (ISO) standard. The conditions of the rotating machine consisted of normal, bearing faults (inner and outer races), shaft misalignment, and rotor unbalance with three different torque load conditions (0 Nm, 2 Nm, and 4 Nm). This article also reports the vibration and driving current dataset of a rolling element bearing under varying speed conditions (680 RPM to 2460 RPM). The established dataset can be used to verify newly developed state-of-the-art methods for fault diagnosis of rotating machines. Mendeley Data. DOI:10.17632/ztmf3m7h5x.6, DOI:10.17632/vxkj334rzv.7, DOI:10.17632/x3vhp8t6hg.7, DOI:10.17632/j8d8pfkvj2.7
format Online
Article
Text
id pubmed-10036499
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-100364992023-03-25 Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis Jung, Wonho Kim, Seong-Hu Yun, Sung-Hyun Bae, Jaewoong Park, Yong-Hwa Data Brief Data Article Rotating machines are often operated under various operating conditions. However, the characteristics of the data varies with their operating conditions. This article presents the time-series dataset, including vibration, acoustic, temperature, and driving current data of rotating machines under varying operating conditions. The dataset was acquired using four ceramic shear ICP based accelerometers, one microphone, two thermocouples, and three current transformer (CT) based on the international organization for standardization (ISO) standard. The conditions of the rotating machine consisted of normal, bearing faults (inner and outer races), shaft misalignment, and rotor unbalance with three different torque load conditions (0 Nm, 2 Nm, and 4 Nm). This article also reports the vibration and driving current dataset of a rolling element bearing under varying speed conditions (680 RPM to 2460 RPM). The established dataset can be used to verify newly developed state-of-the-art methods for fault diagnosis of rotating machines. Mendeley Data. DOI:10.17632/ztmf3m7h5x.6, DOI:10.17632/vxkj334rzv.7, DOI:10.17632/x3vhp8t6hg.7, DOI:10.17632/j8d8pfkvj2.7 Elsevier 2023-03-09 /pmc/articles/PMC10036499/ /pubmed/36969976 http://dx.doi.org/10.1016/j.dib.2023.109049 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Jung, Wonho
Kim, Seong-Hu
Yun, Sung-Hyun
Bae, Jaewoong
Park, Yong-Hwa
Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
title Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
title_full Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
title_fullStr Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
title_full_unstemmed Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
title_short Vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
title_sort vibration, acoustic, temperature, and motor current dataset of rotating machine under varying operating conditions for fault diagnosis
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036499/
https://www.ncbi.nlm.nih.gov/pubmed/36969976
http://dx.doi.org/10.1016/j.dib.2023.109049
work_keys_str_mv AT jungwonho vibrationacoustictemperatureandmotorcurrentdatasetofrotatingmachineundervaryingoperatingconditionsforfaultdiagnosis
AT kimseonghu vibrationacoustictemperatureandmotorcurrentdatasetofrotatingmachineundervaryingoperatingconditionsforfaultdiagnosis
AT yunsunghyun vibrationacoustictemperatureandmotorcurrentdatasetofrotatingmachineundervaryingoperatingconditionsforfaultdiagnosis
AT baejaewoong vibrationacoustictemperatureandmotorcurrentdatasetofrotatingmachineundervaryingoperatingconditionsforfaultdiagnosis
AT parkyonghwa vibrationacoustictemperatureandmotorcurrentdatasetofrotatingmachineundervaryingoperatingconditionsforfaultdiagnosis