Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET

Examining impacts of differential mode (DM) filter topologies covering pi, LC with damping, LC, LCL filter through isolated Ćuk single phase PFC converter is realized in this paper regarding to power factor, THD and efficiency. Application of PFC isolated Ćuk converter is conducted with 42 kHz switc...

Descripción completa

Detalles Bibliográficos
Autor principal: Şehirli, Erdal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036539/
https://www.ncbi.nlm.nih.gov/pubmed/36959232
http://dx.doi.org/10.1038/s41598-023-31965-2
_version_ 1784911678518853632
author Şehirli, Erdal
author_facet Şehirli, Erdal
author_sort Şehirli, Erdal
collection PubMed
description Examining impacts of differential mode (DM) filter topologies covering pi, LC with damping, LC, LCL filter through isolated Ćuk single phase PFC converter is realized in this paper regarding to power factor, THD and efficiency. Application of PFC isolated Ćuk converter is conducted with 42 kHz switching frequency and 50 W power. Each filter is modeled, designed, and applied experimentally via isolated PFC Ćuk converter. Average model derivation based on state-space, for DCM operation of input side inductor of isolated PFC Ćuk converter that is not introduced in literature is the main contribution of the paper. Second main contribution is to analyze filter types by linear methods for the transfer functions cascading the converter and filter transfer functions, which is not presented for PFC converters. It is also presented that solely LCL filter which is not analyzed for PFC converters in detail in literature, does not give desired results. So, increasing the effectivity of LCL filter, new filter structure LCL with parallel C filter is proposed and modeled in this paper. Thanks to the applications, presented results of LCL with parallel C filter is better than others with 4.9% current THD and ‘1’ power factor. Proposed LCL filter ensures 45% reduction of total inductor value, comparing to LC filter. Besides, LCL with C filter provides better control characteristics with maximum allowable gain for stability as 0.7585 higher than other topologies. Moreover, practical design methodology of filter types avoiding complex mathematical procedure is given in this paper. Applications with each filters provide THD requirements, obtained 4.9% as a best value, lower than IEC61000-3-2 standard. Maximum percentage improvement comparing to the IEC61000-3-2 is 27.5% for third harmonic. Furthermore, SiC and Si Mosfets are employed separately in the converter and compared by using each DM filters regarding to power factor, THD, efficiency through applications. As a result, better efficiency with SiC Mosfet as 83% and better THD with Si Mosfet as 4.9% are conducted.
format Online
Article
Text
id pubmed-10036539
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-100365392023-03-25 Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET Şehirli, Erdal Sci Rep Article Examining impacts of differential mode (DM) filter topologies covering pi, LC with damping, LC, LCL filter through isolated Ćuk single phase PFC converter is realized in this paper regarding to power factor, THD and efficiency. Application of PFC isolated Ćuk converter is conducted with 42 kHz switching frequency and 50 W power. Each filter is modeled, designed, and applied experimentally via isolated PFC Ćuk converter. Average model derivation based on state-space, for DCM operation of input side inductor of isolated PFC Ćuk converter that is not introduced in literature is the main contribution of the paper. Second main contribution is to analyze filter types by linear methods for the transfer functions cascading the converter and filter transfer functions, which is not presented for PFC converters. It is also presented that solely LCL filter which is not analyzed for PFC converters in detail in literature, does not give desired results. So, increasing the effectivity of LCL filter, new filter structure LCL with parallel C filter is proposed and modeled in this paper. Thanks to the applications, presented results of LCL with parallel C filter is better than others with 4.9% current THD and ‘1’ power factor. Proposed LCL filter ensures 45% reduction of total inductor value, comparing to LC filter. Besides, LCL with C filter provides better control characteristics with maximum allowable gain for stability as 0.7585 higher than other topologies. Moreover, practical design methodology of filter types avoiding complex mathematical procedure is given in this paper. Applications with each filters provide THD requirements, obtained 4.9% as a best value, lower than IEC61000-3-2 standard. Maximum percentage improvement comparing to the IEC61000-3-2 is 27.5% for third harmonic. Furthermore, SiC and Si Mosfets are employed separately in the converter and compared by using each DM filters regarding to power factor, THD, efficiency through applications. As a result, better efficiency with SiC Mosfet as 83% and better THD with Si Mosfet as 4.9% are conducted. Nature Publishing Group UK 2023-03-23 /pmc/articles/PMC10036539/ /pubmed/36959232 http://dx.doi.org/10.1038/s41598-023-31965-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Şehirli, Erdal
Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET
title Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET
title_full Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET
title_fullStr Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET
title_full_unstemmed Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET
title_short Examining the impacts of DM filters to PFC isolated Ćuk converter for DCM operation by comparing Si and SiC MOSFET
title_sort examining the impacts of dm filters to pfc isolated ćuk converter for dcm operation by comparing si and sic mosfet
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036539/
https://www.ncbi.nlm.nih.gov/pubmed/36959232
http://dx.doi.org/10.1038/s41598-023-31965-2
work_keys_str_mv AT sehirlierdal examiningtheimpactsofdmfilterstopfcisolatedcukconverterfordcmoperationbycomparingsiandsicmosfet