Cargando…
Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale
The paediatric version of Wisconsin Gait Scale (WGS) is a reliable tool for gait assessment in children with spastic hemiplegic cerebral palsy (CP). We decided to develop a solution which will make it possible to objectify the descriptive paediatric version of the WGS, and which, consequently, will...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036550/ https://www.ncbi.nlm.nih.gov/pubmed/36959308 http://dx.doi.org/10.1038/s41598-023-31436-8 |
_version_ | 1784911680787972096 |
---|---|
author | Guzik, Agnieszka Wolan-Nieroda, Andżelina Drużbicki, Mariusz |
author_facet | Guzik, Agnieszka Wolan-Nieroda, Andżelina Drużbicki, Mariusz |
author_sort | Guzik, Agnieszka |
collection | PubMed |
description | The paediatric version of Wisconsin Gait Scale (WGS) is a reliable tool for gait assessment in children with spastic hemiplegic cerebral palsy (CP). We decided to develop a solution which will make it possible to objectify the descriptive paediatric version of the WGS, and which, consequently, will allow researchers/clinicians to more easily perform accurate assessment of gait patterns in patients. The aim of the study was to assess inter- and intra-rater reliability of new application software for computerised paediatric version of the WGS in children with hemiplegic CP. The study involved 31 children with hemiplegic CP. The app was designed using a model based on thematic categories of the paediatric WGS, and utilising auxiliary lines between specific points on the patient’s body, and taking into account angular values, duration and length of the specific gait phases, in order to enable acquisition of quantitative data corresponding to the components of the WGS. The gait of the study participants was recorded, in series of videos. These provided material for three independent raters who reviewed the recordings twice and assessed the participants’ gait using the app. After the evaluation was completed, the data were retrieved from the software. The new application software for the computerised paediatric WGS presents very good inter- and intra-rater reliability. Intra-class correlation coefficient (ICC) was very high in measurement 1 (ICC > 0.9) and 2 (ICC > 0.8), which reflects a very high degree of agreement between the three examiners; there was also high agreement for the specific examiners, between the two measurements (ICC > 0.9). The observational gait scale, objectified through the new software, and enabling computer-aided use of the paediatric WGS, presents practical advantages for examiners since it facilitates decisions taken in the process of WGS-based assessment in children with spastic hemiplegic CP. |
format | Online Article Text |
id | pubmed-10036550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-100365502023-03-25 Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale Guzik, Agnieszka Wolan-Nieroda, Andżelina Drużbicki, Mariusz Sci Rep Article The paediatric version of Wisconsin Gait Scale (WGS) is a reliable tool for gait assessment in children with spastic hemiplegic cerebral palsy (CP). We decided to develop a solution which will make it possible to objectify the descriptive paediatric version of the WGS, and which, consequently, will allow researchers/clinicians to more easily perform accurate assessment of gait patterns in patients. The aim of the study was to assess inter- and intra-rater reliability of new application software for computerised paediatric version of the WGS in children with hemiplegic CP. The study involved 31 children with hemiplegic CP. The app was designed using a model based on thematic categories of the paediatric WGS, and utilising auxiliary lines between specific points on the patient’s body, and taking into account angular values, duration and length of the specific gait phases, in order to enable acquisition of quantitative data corresponding to the components of the WGS. The gait of the study participants was recorded, in series of videos. These provided material for three independent raters who reviewed the recordings twice and assessed the participants’ gait using the app. After the evaluation was completed, the data were retrieved from the software. The new application software for the computerised paediatric WGS presents very good inter- and intra-rater reliability. Intra-class correlation coefficient (ICC) was very high in measurement 1 (ICC > 0.9) and 2 (ICC > 0.8), which reflects a very high degree of agreement between the three examiners; there was also high agreement for the specific examiners, between the two measurements (ICC > 0.9). The observational gait scale, objectified through the new software, and enabling computer-aided use of the paediatric WGS, presents practical advantages for examiners since it facilitates decisions taken in the process of WGS-based assessment in children with spastic hemiplegic CP. Nature Publishing Group UK 2023-03-23 /pmc/articles/PMC10036550/ /pubmed/36959308 http://dx.doi.org/10.1038/s41598-023-31436-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Guzik, Agnieszka Wolan-Nieroda, Andżelina Drużbicki, Mariusz Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale |
title | Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale |
title_full | Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale |
title_fullStr | Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale |
title_full_unstemmed | Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale |
title_short | Inter- and intra-rater reliability of new application software for computerised paediatric version of Wisconsin Gait Scale |
title_sort | inter- and intra-rater reliability of new application software for computerised paediatric version of wisconsin gait scale |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10036550/ https://www.ncbi.nlm.nih.gov/pubmed/36959308 http://dx.doi.org/10.1038/s41598-023-31436-8 |
work_keys_str_mv | AT guzikagnieszka interandintraraterreliabilityofnewapplicationsoftwareforcomputerisedpaediatricversionofwisconsingaitscale AT wolannierodaandzelina interandintraraterreliabilityofnewapplicationsoftwareforcomputerisedpaediatricversionofwisconsingaitscale AT druzbickimariusz interandintraraterreliabilityofnewapplicationsoftwareforcomputerisedpaediatricversionofwisconsingaitscale |