Comparison between Fixation with Smooth Kirschner Wire and Cannulated Screws in Displaced Fractures of the Lateral Humeral Condyle in Children
Objective To compare the use of cannulated screws and smooth Kirschner wires in terms of reducing the presence of exuberant callus and complications in pediatric displaced fractures of the lateral humeral condyle. Methods An analytical cross-sectional study of consecutive cases was conducted from...