Cargando…

Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels

Mechanical forces modify the cell membrane potential by opening mechanosensitive ion channels. We report the design and construction of a lipid bilayer tensiometer to study channels that respond to lateral membrane tension, [Formula: see text]  , in the range 0.2 to 1.4 [Formula: see text] (0.8 to 5...

Descripción completa

Detalles Bibliográficos
Autores principales: Pérez-Mitta, Gonzalo, MacKinnon, Roderick
Formato: Online Artículo Texto
Lenguaje:English
Publicado: National Academy of Sciences 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10041094/
https://www.ncbi.nlm.nih.gov/pubmed/36913590
http://dx.doi.org/10.1073/pnas.2221541120
_version_ 1784912631258152960
author Pérez-Mitta, Gonzalo
MacKinnon, Roderick
author_facet Pérez-Mitta, Gonzalo
MacKinnon, Roderick
author_sort Pérez-Mitta, Gonzalo
collection PubMed
description Mechanical forces modify the cell membrane potential by opening mechanosensitive ion channels. We report the design and construction of a lipid bilayer tensiometer to study channels that respond to lateral membrane tension, [Formula: see text]  , in the range 0.2 to 1.4 [Formula: see text] (0.8 to 5.7 [Formula: see text]  ). The instrument consists of a black-lipid-membrane bilayer, a custom-built microscope, and a high-resolution manometer. Values of [Formula: see text] are obtained from the determination of the bilayer curvature as a function of applied pressure by means of the Young–Laplace equation. We demonstrate that [Formula: see text] can be determined by calculating the bilayer radius of curvature from fluorescence microscopy imaging or from measurements of the bilayer’s electrical capacitance, both yielding similar results. Using electrical capacitance, we show that the mechanosensitive potassium channel TRAAK responds to [Formula: see text]  , not curvature. TRAAK channel open probability increases as [Formula: see text] is increased from 0.2 to 1.4 [Formula: see text] but open probability never reaches 0.5. Thus, TRAAK opens over a wide range of [Formula: see text]  , but with a tension sensitivity about one-fifth that of the bacterial mechanosensitive channel MscL.
format Online
Article
Text
id pubmed-10041094
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher National Academy of Sciences
record_format MEDLINE/PubMed
spelling pubmed-100410942023-03-28 Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels Pérez-Mitta, Gonzalo MacKinnon, Roderick Proc Natl Acad Sci U S A Biological Sciences Mechanical forces modify the cell membrane potential by opening mechanosensitive ion channels. We report the design and construction of a lipid bilayer tensiometer to study channels that respond to lateral membrane tension, [Formula: see text]  , in the range 0.2 to 1.4 [Formula: see text] (0.8 to 5.7 [Formula: see text]  ). The instrument consists of a black-lipid-membrane bilayer, a custom-built microscope, and a high-resolution manometer. Values of [Formula: see text] are obtained from the determination of the bilayer curvature as a function of applied pressure by means of the Young–Laplace equation. We demonstrate that [Formula: see text] can be determined by calculating the bilayer radius of curvature from fluorescence microscopy imaging or from measurements of the bilayer’s electrical capacitance, both yielding similar results. Using electrical capacitance, we show that the mechanosensitive potassium channel TRAAK responds to [Formula: see text]  , not curvature. TRAAK channel open probability increases as [Formula: see text] is increased from 0.2 to 1.4 [Formula: see text] but open probability never reaches 0.5. Thus, TRAAK opens over a wide range of [Formula: see text]  , but with a tension sensitivity about one-fifth that of the bacterial mechanosensitive channel MscL. National Academy of Sciences 2023-03-13 2023-03-21 /pmc/articles/PMC10041094/ /pubmed/36913590 http://dx.doi.org/10.1073/pnas.2221541120 Text en Copyright © 2023 the Author(s). Published by PNAS. https://creativecommons.org/licenses/by/4.0/This open access article is distributed under Creative Commons Attribution License 4.0 (CC BY) (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Biological Sciences
Pérez-Mitta, Gonzalo
MacKinnon, Roderick
Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
title Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
title_full Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
title_fullStr Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
title_full_unstemmed Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
title_short Freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
title_sort freestanding lipid bilayer tensiometer for the study of mechanosensitive ion channels
topic Biological Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10041094/
https://www.ncbi.nlm.nih.gov/pubmed/36913590
http://dx.doi.org/10.1073/pnas.2221541120
work_keys_str_mv AT perezmittagonzalo freestandinglipidbilayertensiometerforthestudyofmechanosensitiveionchannels
AT mackinnonroderick freestandinglipidbilayertensiometerforthestudyofmechanosensitiveionchannels