Cargando…

Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis

The reverse-transcription loop-mediated isothermal amplification (RT-LAMP) is a cheaper and faster testing alternative for detecting SARS-CoV-2. However, a high false-positive rate due to misamplification is one of the major limitations. To overcome misamplifications, we developed colorimetric and f...

Descripción completa

Detalles Bibliográficos
Autores principales: Alhamid, Galyah, Tombuloglu, Huseyin, Al-Suhaimi, Ebtesam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10044074/
https://www.ncbi.nlm.nih.gov/pubmed/36977756
http://dx.doi.org/10.1038/s41598-023-31760-z
_version_ 1784913284871225344
author Alhamid, Galyah
Tombuloglu, Huseyin
Al-Suhaimi, Ebtesam
author_facet Alhamid, Galyah
Tombuloglu, Huseyin
Al-Suhaimi, Ebtesam
author_sort Alhamid, Galyah
collection PubMed
description The reverse-transcription loop-mediated isothermal amplification (RT-LAMP) is a cheaper and faster testing alternative for detecting SARS-CoV-2. However, a high false-positive rate due to misamplification is one of the major limitations. To overcome misamplifications, we developed colorimetric and fluorometric RT-LAMP assays using five LAMP primers, instead of six. The gold-standard RT-PCR technique verified the assays' performance. Compared to other primer sets with six primers (N, S, and RdRp), the E-ID1 primer set, including five primers, performed superbly on both colorimetric and fluorometric assays. The sensitivity of colorimetric and fluorometric assays was 89.5% and 92.2%, respectively, with a limit of detection of 20 copies/µL. The colorimetric RT-LAMP had a specificity of 97.2% and an accuracy of 94.5%, while the fluorometric RT-LAMP obtained 99% and 96.7%, respectively. No misamplification was evident even after 120 min, which is crucial for the success of this technique. These findings are important to support the use of RT-LAMP in the healthcare systems in fighting COVID-19.
format Online
Article
Text
id pubmed-10044074
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-100440742023-03-28 Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis Alhamid, Galyah Tombuloglu, Huseyin Al-Suhaimi, Ebtesam Sci Rep Article The reverse-transcription loop-mediated isothermal amplification (RT-LAMP) is a cheaper and faster testing alternative for detecting SARS-CoV-2. However, a high false-positive rate due to misamplification is one of the major limitations. To overcome misamplifications, we developed colorimetric and fluorometric RT-LAMP assays using five LAMP primers, instead of six. The gold-standard RT-PCR technique verified the assays' performance. Compared to other primer sets with six primers (N, S, and RdRp), the E-ID1 primer set, including five primers, performed superbly on both colorimetric and fluorometric assays. The sensitivity of colorimetric and fluorometric assays was 89.5% and 92.2%, respectively, with a limit of detection of 20 copies/µL. The colorimetric RT-LAMP had a specificity of 97.2% and an accuracy of 94.5%, while the fluorometric RT-LAMP obtained 99% and 96.7%, respectively. No misamplification was evident even after 120 min, which is crucial for the success of this technique. These findings are important to support the use of RT-LAMP in the healthcare systems in fighting COVID-19. Nature Publishing Group UK 2023-03-28 /pmc/articles/PMC10044074/ /pubmed/36977756 http://dx.doi.org/10.1038/s41598-023-31760-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Alhamid, Galyah
Tombuloglu, Huseyin
Al-Suhaimi, Ebtesam
Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis
title Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis
title_full Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis
title_fullStr Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis
title_full_unstemmed Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis
title_short Development of loop-mediated isothermal amplification (LAMP) assays using five primers reduces the false-positive rate in COVID-19 diagnosis
title_sort development of loop-mediated isothermal amplification (lamp) assays using five primers reduces the false-positive rate in covid-19 diagnosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10044074/
https://www.ncbi.nlm.nih.gov/pubmed/36977756
http://dx.doi.org/10.1038/s41598-023-31760-z
work_keys_str_mv AT alhamidgalyah developmentofloopmediatedisothermalamplificationlampassaysusingfiveprimersreducesthefalsepositiverateincovid19diagnosis
AT tombulogluhuseyin developmentofloopmediatedisothermalamplificationlampassaysusingfiveprimersreducesthefalsepositiverateincovid19diagnosis
AT alsuhaimiebtesam developmentofloopmediatedisothermalamplificationlampassaysusingfiveprimersreducesthefalsepositiverateincovid19diagnosis