Cargando…
Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial
BACKGROUND: Incisional hernia is a frequent complication after loop-ileostomy closure, rationalizing hernia prevention. Biological meshes have been widely used in contaminated surgical sites instead of synthetic meshes in fear of mesh related complications. However, previous studies on meshes does n...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10045611/ https://www.ncbi.nlm.nih.gov/pubmed/36973782 http://dx.doi.org/10.1186/s12893-023-01961-4 |
_version_ | 1784913647193030656 |
---|---|
author | Mäkäräinen, Elisa J Wiik, Heikki T Kössi, Jyrki AO Pinta, Tarja M Mäntymäki, Leena-Mari J Mattila, Anne K Kairaluoma, Matti VJ Ohtonen, Pasi P Rautio, Tero T |
author_facet | Mäkäräinen, Elisa J Wiik, Heikki T Kössi, Jyrki AO Pinta, Tarja M Mäntymäki, Leena-Mari J Mattila, Anne K Kairaluoma, Matti VJ Ohtonen, Pasi P Rautio, Tero T |
author_sort | Mäkäräinen, Elisa J |
collection | PubMed |
description | BACKGROUND: Incisional hernia is a frequent complication after loop-ileostomy closure, rationalizing hernia prevention. Biological meshes have been widely used in contaminated surgical sites instead of synthetic meshes in fear of mesh related complications. However, previous studies on meshes does not support this practice. The aim of Preloop trial was to study the safety and efficacy of synthetic mesh compared to a biological mesh in incisional hernia prevention after loop-ileostomy closure. METHODS: The Preloop randomized, feasibility trial was conducted from April 2018 until November 2021 in four hospitals in Finland. The trial enrolled 102 patients with temporary loop-ileostomy after anterior resection for rectal cancer. The study patients were randomized 1:1 to receive either a light-weight synthetic polypropylene mesh (Parietene Macro™, Medtronic) (SM) or a biological mesh (Permacol™, Medtronic) (BM) to the retrorectus space at ileostomy closure. The primary end points were rate of surgical site infections (SSI) at 30-day follow-up and incisional hernia rate during 10 months’ follow-up period. RESULTS: Of 102 patients randomized, 97 received the intended allocation. At 30-day follow-up, 94 (97%) patients were evaluated. In the SM group, 1/46 (2%) had SSI. Uneventful recovery was reported in 38/46 (86%) in SM group. In the BM group, 2/48 (4%) had SSI (p > 0.90) and in 43/48 (90%) uneventful recovery was reported. The mesh was removed from one patient in both groups (p > 0.90). CONCLUSIONS: Both a synthetic mesh and biological mesh were safe in terms of SSI after loop-ileostomy closure. Hernia prevention efficacy will be published after the study patients have completed the 10 months’ follow-up. |
format | Online Article Text |
id | pubmed-10045611 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-100456112023-03-29 Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial Mäkäräinen, Elisa J Wiik, Heikki T Kössi, Jyrki AO Pinta, Tarja M Mäntymäki, Leena-Mari J Mattila, Anne K Kairaluoma, Matti VJ Ohtonen, Pasi P Rautio, Tero T BMC Surg Research BACKGROUND: Incisional hernia is a frequent complication after loop-ileostomy closure, rationalizing hernia prevention. Biological meshes have been widely used in contaminated surgical sites instead of synthetic meshes in fear of mesh related complications. However, previous studies on meshes does not support this practice. The aim of Preloop trial was to study the safety and efficacy of synthetic mesh compared to a biological mesh in incisional hernia prevention after loop-ileostomy closure. METHODS: The Preloop randomized, feasibility trial was conducted from April 2018 until November 2021 in four hospitals in Finland. The trial enrolled 102 patients with temporary loop-ileostomy after anterior resection for rectal cancer. The study patients were randomized 1:1 to receive either a light-weight synthetic polypropylene mesh (Parietene Macro™, Medtronic) (SM) or a biological mesh (Permacol™, Medtronic) (BM) to the retrorectus space at ileostomy closure. The primary end points were rate of surgical site infections (SSI) at 30-day follow-up and incisional hernia rate during 10 months’ follow-up period. RESULTS: Of 102 patients randomized, 97 received the intended allocation. At 30-day follow-up, 94 (97%) patients were evaluated. In the SM group, 1/46 (2%) had SSI. Uneventful recovery was reported in 38/46 (86%) in SM group. In the BM group, 2/48 (4%) had SSI (p > 0.90) and in 43/48 (90%) uneventful recovery was reported. The mesh was removed from one patient in both groups (p > 0.90). CONCLUSIONS: Both a synthetic mesh and biological mesh were safe in terms of SSI after loop-ileostomy closure. Hernia prevention efficacy will be published after the study patients have completed the 10 months’ follow-up. BioMed Central 2023-03-27 /pmc/articles/PMC10045611/ /pubmed/36973782 http://dx.doi.org/10.1186/s12893-023-01961-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Mäkäräinen, Elisa J Wiik, Heikki T Kössi, Jyrki AO Pinta, Tarja M Mäntymäki, Leena-Mari J Mattila, Anne K Kairaluoma, Matti VJ Ohtonen, Pasi P Rautio, Tero T Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
title | Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
title_full | Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
title_fullStr | Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
title_full_unstemmed | Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
title_short | Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
title_sort | synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10045611/ https://www.ncbi.nlm.nih.gov/pubmed/36973782 http://dx.doi.org/10.1186/s12893-023-01961-4 |
work_keys_str_mv | AT makarainenelisaj syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT wiikheikkit syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT kossijyrkiao syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT pintatarjam syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT mantymakileenamarij syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT mattilaannek syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT kairaluomamattivj syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT ohtonenpasip syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial AT rautioterot syntheticmeshversusbiologicalmeshtopreventincisionalherniaafterloopileostomyclosurearandomizedfeasibilitytrial |