Cargando…

Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System

Abnormalities in cardiorespiratory measurements have repeatedly been found in patients with panic disorder (PD) during laboratory-based assessments. However, recordings performed outside laboratory settings are required to test the ecological validity of these findings. Wearable devices, such as sen...

Descripción completa

Detalles Bibliográficos
Autores principales: Caldirola, Daniela, Daccò, Silvia, Grassi, Massimiliano, Alciati, Alessandra, Sbabo, William M., De Donatis, Domenico, Martinotti, Giovanni, De Berardis, Domenico, Perna, Giampaolo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046237/
https://www.ncbi.nlm.nih.gov/pubmed/36979312
http://dx.doi.org/10.3390/brainsci13030502
_version_ 1785013621154119680
author Caldirola, Daniela
Daccò, Silvia
Grassi, Massimiliano
Alciati, Alessandra
Sbabo, William M.
De Donatis, Domenico
Martinotti, Giovanni
De Berardis, Domenico
Perna, Giampaolo
author_facet Caldirola, Daniela
Daccò, Silvia
Grassi, Massimiliano
Alciati, Alessandra
Sbabo, William M.
De Donatis, Domenico
Martinotti, Giovanni
De Berardis, Domenico
Perna, Giampaolo
author_sort Caldirola, Daniela
collection PubMed
description Abnormalities in cardiorespiratory measurements have repeatedly been found in patients with panic disorder (PD) during laboratory-based assessments. However, recordings performed outside laboratory settings are required to test the ecological validity of these findings. Wearable devices, such as sensor-imbedded garments, biopatches, and smartwatches, are promising tools for this purpose. We systematically reviewed the evidence for wearables-based cardiorespiratory assessments in PD by searching for publications on the PubMed, PsycINFO, and Embase databases, from inception to 30 July 2022. After the screening of two-hundred and twenty records, eight studies were included. The limited number of available studies and critical aspects related to the uncertain reliability of wearables-based assessments, especially concerning respiration, prevented us from drawing conclusions about the cardiorespiratory function of patients with PD in daily life. We also present preliminary data on a pilot study conducted on volunteers at the Villa San Benedetto Menni Hospital for evaluating the accuracy of heart rate (HR) and breathing rate (BR) measurements by the wearable Zephyr BioPatch compared with the Quark-b2 stationary testing system. Our exploratory results suggested possible BR and HR misestimation by the wearable Zephyr BioPatch compared with the Quark-b2 system. Challenges of wearables-based cardiorespiratory assessment and possible solutions to improve their reliability and optimize their significant potential for the study of PD pathophysiology are presented.
format Online
Article
Text
id pubmed-10046237
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100462372023-03-29 Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System Caldirola, Daniela Daccò, Silvia Grassi, Massimiliano Alciati, Alessandra Sbabo, William M. De Donatis, Domenico Martinotti, Giovanni De Berardis, Domenico Perna, Giampaolo Brain Sci Systematic Review Abnormalities in cardiorespiratory measurements have repeatedly been found in patients with panic disorder (PD) during laboratory-based assessments. However, recordings performed outside laboratory settings are required to test the ecological validity of these findings. Wearable devices, such as sensor-imbedded garments, biopatches, and smartwatches, are promising tools for this purpose. We systematically reviewed the evidence for wearables-based cardiorespiratory assessments in PD by searching for publications on the PubMed, PsycINFO, and Embase databases, from inception to 30 July 2022. After the screening of two-hundred and twenty records, eight studies were included. The limited number of available studies and critical aspects related to the uncertain reliability of wearables-based assessments, especially concerning respiration, prevented us from drawing conclusions about the cardiorespiratory function of patients with PD in daily life. We also present preliminary data on a pilot study conducted on volunteers at the Villa San Benedetto Menni Hospital for evaluating the accuracy of heart rate (HR) and breathing rate (BR) measurements by the wearable Zephyr BioPatch compared with the Quark-b2 stationary testing system. Our exploratory results suggested possible BR and HR misestimation by the wearable Zephyr BioPatch compared with the Quark-b2 system. Challenges of wearables-based cardiorespiratory assessment and possible solutions to improve their reliability and optimize their significant potential for the study of PD pathophysiology are presented. MDPI 2023-03-16 /pmc/articles/PMC10046237/ /pubmed/36979312 http://dx.doi.org/10.3390/brainsci13030502 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Caldirola, Daniela
Daccò, Silvia
Grassi, Massimiliano
Alciati, Alessandra
Sbabo, William M.
De Donatis, Domenico
Martinotti, Giovanni
De Berardis, Domenico
Perna, Giampaolo
Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System
title Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System
title_full Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System
title_fullStr Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System
title_full_unstemmed Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System
title_short Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System
title_sort cardiorespiratory assessments in panic disorder facilitated by wearable devices: a systematic review and brief comparison of the wearable zephyr biopatch with the quark-b2 stationary testing system
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046237/
https://www.ncbi.nlm.nih.gov/pubmed/36979312
http://dx.doi.org/10.3390/brainsci13030502
work_keys_str_mv AT caldiroladaniela cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT daccosilvia cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT grassimassimiliano cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT alciatialessandra cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT sbabowilliamm cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT dedonatisdomenico cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT martinottigiovanni cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT deberardisdomenico cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem
AT pernagiampaolo cardiorespiratoryassessmentsinpanicdisorderfacilitatedbywearabledevicesasystematicreviewandbriefcomparisonofthewearablezephyrbiopatchwiththequarkb2stationarytestingsystem