The adoption of an automated system can decrease the hands-on time requirements in a clinical laboratory setting. For the detection of HLA-B*27, implementing a high-throughput and fully automated system has several advantages over using manual methods. Therefore, this study aimed to evaluate automat...

Descripción completa

Detalles Bibliográficos
Autores principales: Chou, Yung-Che, Er, Tze-Kiong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046602/
https://www.ncbi.nlm.nih.gov/pubmed/36979965
http://dx.doi.org/10.3390/biomedicines11030986
_version_ 1785013714640961536
author Chou, Yung-Che
Er, Tze-Kiong
author_facet Chou, Yung-Che
Er, Tze-Kiong
author_sort Chou, Yung-Che
collection PubMed
description The adoption of an automated system can decrease the hands-on time requirements in a clinical laboratory setting. For the detection of HLA-B*27, implementing a high-throughput and fully automated system has several advantages over using manual methods. Therefore, this study aimed to evaluate automation efficiency for the detection of HLA-B*27. Peripheral blood samples were obtained from 50 participants, and DNA was isolated from these samples. A Pharmigene PG27 detection kit was used for the qualitative detection of HLA-B*27. The performances of the semi-automated and fully automated LabTurbo(TM) AIO systems in the detection of HLA-B*27 were compared. The mean absorbance (optical density) values for the Maelstrom(TM) 8 and LabTurbo(TM) AIO systems were found to be 1.88 and 1.9, respectively. The housekeeping gene was amplified and quantified using a real-time PCR assay across all DNA extracts to check the quality of the extracted human DNA. The results were expressed as the cycle threshold (Ct) values for all DNA extracts from both platforms. The mean Ct values for the Roche Cobas z480 and LabTurbo(TM) AIO systems were found to be 22.7 and 20.4, respectively. This study demonstrated that the semi-automated method and the LabTurbo(TM) AIO system yield consistent results for the detection of HLA-B*27. However, compared to the semi-automated method, the LabTurbo(TM) AIO system provides standardized procedures, avoids manual handling, and improves turnaround time.
format Online
Article
Text
id pubmed-10046602
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100466022023-03-29 High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System Chou, Yung-Che Er, Tze-Kiong Biomedicines Communication The adoption of an automated system can decrease the hands-on time requirements in a clinical laboratory setting. For the detection of HLA-B*27, implementing a high-throughput and fully automated system has several advantages over using manual methods. Therefore, this study aimed to evaluate automation efficiency for the detection of HLA-B*27. Peripheral blood samples were obtained from 50 participants, and DNA was isolated from these samples. A Pharmigene PG27 detection kit was used for the qualitative detection of HLA-B*27. The performances of the semi-automated and fully automated LabTurbo(TM) AIO systems in the detection of HLA-B*27 were compared. The mean absorbance (optical density) values for the Maelstrom(TM) 8 and LabTurbo(TM) AIO systems were found to be 1.88 and 1.9, respectively. The housekeeping gene was amplified and quantified using a real-time PCR assay across all DNA extracts to check the quality of the extracted human DNA. The results were expressed as the cycle threshold (Ct) values for all DNA extracts from both platforms. The mean Ct values for the Roche Cobas z480 and LabTurbo(TM) AIO systems were found to be 22.7 and 20.4, respectively. This study demonstrated that the semi-automated method and the LabTurbo(TM) AIO system yield consistent results for the detection of HLA-B*27. However, compared to the semi-automated method, the LabTurbo(TM) AIO system provides standardized procedures, avoids manual handling, and improves turnaround time. MDPI 2023-03-22 /pmc/articles/PMC10046602/ /pubmed/36979965 http://dx.doi.org/10.3390/biomedicines11030986 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Chou, Yung-Che
Er, Tze-Kiong
High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System
title High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System
title_full High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System
title_fullStr High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System
title_full_unstemmed High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System
title_short High-Throughput and Automated Detection of HLA-B*27 Using the LabTurbo(TM) AIO System
title_sort high-throughput and automated detection of hla-b*27 using the labturbo(tm) aio system
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046602/
https://www.ncbi.nlm.nih.gov/pubmed/36979965
http://dx.doi.org/10.3390/biomedicines11030986
work_keys_str_mv AT chouyungche highthroughputandautomateddetectionofhlab27usingthelabturbotmaiosystem
AT ertzekiong highthroughputandautomateddetectionofhlab27usingthelabturbotmaiosystem