Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study
Purpose: to evaluate and monitor the timely thermal ablation changes of rabbit liver by using two elastographic methods—real-time elastography (RTE) and shear wave elastography (SWE)—as compared to contrast-enhanced ultrasound (CEUS) and physical specimens. Materials and Methods: 20 ablation zones w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046930/ https://www.ncbi.nlm.nih.gov/pubmed/36980453 http://dx.doi.org/10.3390/diagnostics13061145 |
_version_ | 1785013795186278400 |
---|---|
author | Shi, Li Li, Xiaoju Liao, Wei Wu, Wenxin Xu, Ming |
author_facet | Shi, Li Li, Xiaoju Liao, Wei Wu, Wenxin Xu, Ming |
author_sort | Shi, Li |
collection | PubMed |
description | Purpose: to evaluate and monitor the timely thermal ablation changes of rabbit liver by using two elastographic methods—real-time elastography (RTE) and shear wave elastography (SWE)—as compared to contrast-enhanced ultrasound (CEUS) and physical specimens. Materials and Methods: 20 ablation zones were created in the livers of 20 rabbits using radiofrequency ablation (RFA). After the ablation, RTE and SWE were used to measure the elastic properties of the twenty ablation zones. The consistency of efficacy evaluation for RTE and SWE measurements was analyzed using the Bland–Altman test. The areas of the thermal ablation zones were also measured and compared according to the images provided by RTE, SWE, CEUS, and gross physical specimen measurement. Results: RTE and SWE could clearly display the shape of RFA ablation zones within one hour after the ablation. The average elasticity ratio for the ablation zone measured by RTE was 3.41 ± 0.67 (2.23–4.76); the average elasticity value measured by SWE was 50.7 ± 11.3 kPa (33.2–70.4 kPa). The mean areas of the ablation zones measured with RTE, SWE, gross specimen, and CEUS were 1.089 ± 0.199 cm(2), 1.059 ± 0.201 cm(2), 1.081 ± 0.201 cm(2), and 3.091 ± 0.591 cm(2), respectively. The Bland–Altman test showed that RTE and SWE have great consistency. Area measurements by CEUS were significantly larger than those of the other three methods (p < 0.05). Conclusion: RTE and SWE are both able to accurately confirm the range of ablation zones shortly after the ablation for rabbit livers. |
format | Online Article Text |
id | pubmed-10046930 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100469302023-03-29 Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study Shi, Li Li, Xiaoju Liao, Wei Wu, Wenxin Xu, Ming Diagnostics (Basel) Article Purpose: to evaluate and monitor the timely thermal ablation changes of rabbit liver by using two elastographic methods—real-time elastography (RTE) and shear wave elastography (SWE)—as compared to contrast-enhanced ultrasound (CEUS) and physical specimens. Materials and Methods: 20 ablation zones were created in the livers of 20 rabbits using radiofrequency ablation (RFA). After the ablation, RTE and SWE were used to measure the elastic properties of the twenty ablation zones. The consistency of efficacy evaluation for RTE and SWE measurements was analyzed using the Bland–Altman test. The areas of the thermal ablation zones were also measured and compared according to the images provided by RTE, SWE, CEUS, and gross physical specimen measurement. Results: RTE and SWE could clearly display the shape of RFA ablation zones within one hour after the ablation. The average elasticity ratio for the ablation zone measured by RTE was 3.41 ± 0.67 (2.23–4.76); the average elasticity value measured by SWE was 50.7 ± 11.3 kPa (33.2–70.4 kPa). The mean areas of the ablation zones measured with RTE, SWE, gross specimen, and CEUS were 1.089 ± 0.199 cm(2), 1.059 ± 0.201 cm(2), 1.081 ± 0.201 cm(2), and 3.091 ± 0.591 cm(2), respectively. The Bland–Altman test showed that RTE and SWE have great consistency. Area measurements by CEUS were significantly larger than those of the other three methods (p < 0.05). Conclusion: RTE and SWE are both able to accurately confirm the range of ablation zones shortly after the ablation for rabbit livers. MDPI 2023-03-16 /pmc/articles/PMC10046930/ /pubmed/36980453 http://dx.doi.org/10.3390/diagnostics13061145 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shi, Li Li, Xiaoju Liao, Wei Wu, Wenxin Xu, Ming Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study |
title | Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study |
title_full | Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study |
title_fullStr | Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study |
title_full_unstemmed | Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study |
title_short | Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study |
title_sort | real-time elastography versus shear wave elastography on evaluating the timely radiofrequency ablation effect of rabbit liver: a preliminary experimental study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10046930/ https://www.ncbi.nlm.nih.gov/pubmed/36980453 http://dx.doi.org/10.3390/diagnostics13061145 |
work_keys_str_mv | AT shili realtimeelastographyversusshearwaveelastographyonevaluatingthetimelyradiofrequencyablationeffectofrabbitliverapreliminaryexperimentalstudy AT lixiaoju realtimeelastographyversusshearwaveelastographyonevaluatingthetimelyradiofrequencyablationeffectofrabbitliverapreliminaryexperimentalstudy AT liaowei realtimeelastographyversusshearwaveelastographyonevaluatingthetimelyradiofrequencyablationeffectofrabbitliverapreliminaryexperimentalstudy AT wuwenxin realtimeelastographyversusshearwaveelastographyonevaluatingthetimelyradiofrequencyablationeffectofrabbitliverapreliminaryexperimentalstudy AT xuming realtimeelastographyversusshearwaveelastographyonevaluatingthetimelyradiofrequencyablationeffectofrabbitliverapreliminaryexperimentalstudy |