Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps
(1) Objective: To evaluate the diagnostic performance of prototype handheld ultrasound compared to automated breast ultrasound, according to the fifth edition of BI-RADS categorization, among females with positive lumps. (2) Methods: A total of 1004 lesions in 162 participants who underwent both pro...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10047253/ https://www.ncbi.nlm.nih.gov/pubmed/36980373 http://dx.doi.org/10.3390/diagnostics13061065 |
_version_ | 1785013874558238720 |
---|---|
author | Ibraheem, Shahad A. Mahmud, Rozi Mohamad Saini, Suraini Abu Hassan, Hasyma Keiteb, Aysar Sabah |
author_facet | Ibraheem, Shahad A. Mahmud, Rozi Mohamad Saini, Suraini Abu Hassan, Hasyma Keiteb, Aysar Sabah |
author_sort | Ibraheem, Shahad A. |
collection | PubMed |
description | (1) Objective: To evaluate the diagnostic performance of prototype handheld ultrasound compared to automated breast ultrasound, according to the fifth edition of BI-RADS categorization, among females with positive lumps. (2) Methods: A total of 1004 lesions in 162 participants who underwent both prototype handheld ultrasound and automated breast ultrasound were included. Two radiologists and a sonographer independently evaluated the sonographic features of each lesion according to the fifth BI-RADS edition. The kappa coefficient (κ) was calculated for each BI-RADS descriptor and final assessment category. The cross-tabulation was performed to see whether there were differences between the ABUS and prototype HHUS results. Specificity and sensitivity were evaluated and compared using the McNamar test. (3) Results: ABUS and prototype HHUS observers found the same number of breast lesions in the 324 breasts of the 162 respondents. There was no significant difference in the mean lesion size, with a maximum mean length dimension of 0.48 ± 0.33 cm. The assessment of the lesion’s shape, orientation, margin, echo pattern, posterior acoustic features, and calcification was obtained with good to excellent agreements between ABUS and prototype HHUS observers (κ = 0.70–1.0). There was absolutely no significant difference between ABUS and prototype HHUS in assessment of lesion except for lesion orientation p = 0.00. Diagnostic accuracy (99.8% and 97.7–98.9%), sensitivity (99.5% and 98.0–99.0%), specificity (99.8% and 99.6–99.8%), positive predictive value (98.1% and 90.3–96.2%), negative predictive value (90.0% and 84.4–88.7%), and areas under the curve (0.98 and 0.83–0.92; p < 0.05) were not significantly different between ABUS and prototype HHUS observers. (4) Conclusion: According to the fifth BI-RADS edition, automated breast ultrasound is not statistically significantly different from prototype handheld ultrasound with regard to interobserver variability and diagnostic performance. |
format | Online Article Text |
id | pubmed-10047253 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100472532023-03-29 Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps Ibraheem, Shahad A. Mahmud, Rozi Mohamad Saini, Suraini Abu Hassan, Hasyma Keiteb, Aysar Sabah Diagnostics (Basel) Article (1) Objective: To evaluate the diagnostic performance of prototype handheld ultrasound compared to automated breast ultrasound, according to the fifth edition of BI-RADS categorization, among females with positive lumps. (2) Methods: A total of 1004 lesions in 162 participants who underwent both prototype handheld ultrasound and automated breast ultrasound were included. Two radiologists and a sonographer independently evaluated the sonographic features of each lesion according to the fifth BI-RADS edition. The kappa coefficient (κ) was calculated for each BI-RADS descriptor and final assessment category. The cross-tabulation was performed to see whether there were differences between the ABUS and prototype HHUS results. Specificity and sensitivity were evaluated and compared using the McNamar test. (3) Results: ABUS and prototype HHUS observers found the same number of breast lesions in the 324 breasts of the 162 respondents. There was no significant difference in the mean lesion size, with a maximum mean length dimension of 0.48 ± 0.33 cm. The assessment of the lesion’s shape, orientation, margin, echo pattern, posterior acoustic features, and calcification was obtained with good to excellent agreements between ABUS and prototype HHUS observers (κ = 0.70–1.0). There was absolutely no significant difference between ABUS and prototype HHUS in assessment of lesion except for lesion orientation p = 0.00. Diagnostic accuracy (99.8% and 97.7–98.9%), sensitivity (99.5% and 98.0–99.0%), specificity (99.8% and 99.6–99.8%), positive predictive value (98.1% and 90.3–96.2%), negative predictive value (90.0% and 84.4–88.7%), and areas under the curve (0.98 and 0.83–0.92; p < 0.05) were not significantly different between ABUS and prototype HHUS observers. (4) Conclusion: According to the fifth BI-RADS edition, automated breast ultrasound is not statistically significantly different from prototype handheld ultrasound with regard to interobserver variability and diagnostic performance. MDPI 2023-03-11 /pmc/articles/PMC10047253/ /pubmed/36980373 http://dx.doi.org/10.3390/diagnostics13061065 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ibraheem, Shahad A. Mahmud, Rozi Mohamad Saini, Suraini Abu Hassan, Hasyma Keiteb, Aysar Sabah Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps |
title | Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps |
title_full | Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps |
title_fullStr | Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps |
title_full_unstemmed | Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps |
title_short | Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps |
title_sort | diagnostic performance of prototype handheld ultrasound according to the fifth edition of bi-rads for breast ultrasound compared with automated breast ultrasound among females with positive lumps |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10047253/ https://www.ncbi.nlm.nih.gov/pubmed/36980373 http://dx.doi.org/10.3390/diagnostics13061065 |
work_keys_str_mv | AT ibraheemshahada diagnosticperformanceofprototypehandheldultrasoundaccordingtothefiftheditionofbiradsforbreastultrasoundcomparedwithautomatedbreastultrasoundamongfemaleswithpositivelumps AT mahmudrozi diagnosticperformanceofprototypehandheldultrasoundaccordingtothefiftheditionofbiradsforbreastultrasoundcomparedwithautomatedbreastultrasoundamongfemaleswithpositivelumps AT mohamadsainisuraini diagnosticperformanceofprototypehandheldultrasoundaccordingtothefiftheditionofbiradsforbreastultrasoundcomparedwithautomatedbreastultrasoundamongfemaleswithpositivelumps AT abuhassanhasyma diagnosticperformanceofprototypehandheldultrasoundaccordingtothefiftheditionofbiradsforbreastultrasoundcomparedwithautomatedbreastultrasoundamongfemaleswithpositivelumps AT keitebaysarsabah diagnosticperformanceofprototypehandheldultrasoundaccordingtothefiftheditionofbiradsforbreastultrasoundcomparedwithautomatedbreastultrasoundamongfemaleswithpositivelumps |