Aim of the study: We evaluated and compared blood gas analysis (EGA) non-conformities (NC) considered operator-dependent performed in Point-Of-Care (POC) analyzer as quality indicators (IQ) of the pre-analytical phase. To this end, four different NC registered in the resuscitation departments of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Brescia, Vincenzo, Varraso, Lucia, Antonucci, Mariantonietta, Lovero, Roberto, Schirinzi, Annalisa, Mascolo, Elisa, Di Serio, Francesca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10047429/
https://www.ncbi.nlm.nih.gov/pubmed/36980352
http://dx.doi.org/10.3390/diagnostics13061044
_version_ 1785013921202044928
author Brescia, Vincenzo
Varraso, Lucia
Antonucci, Mariantonietta
Lovero, Roberto
Schirinzi, Annalisa
Mascolo, Elisa
Di Serio, Francesca
author_facet Brescia, Vincenzo
Varraso, Lucia
Antonucci, Mariantonietta
Lovero, Roberto
Schirinzi, Annalisa
Mascolo, Elisa
Di Serio, Francesca
author_sort Brescia, Vincenzo
collection PubMed
description Aim of the study: We evaluated and compared blood gas analysis (EGA) non-conformities (NC) considered operator-dependent performed in Point-Of-Care (POC) analyzer as quality indicators (IQ) of the pre-analytical phase. To this end, four different NC registered in the resuscitation departments of the Hospital Polyclinic Bari from the beginning of the pandemic (March 2020) until February 2022 were evaluated. The results obtained were compared with those recorded in the pre-COVID period (March 2018–February 2020) to check if there were differences in number and type. Material and methods: GEM 4000 series blood gas analyzers (Instrumentation Laboratory, Bedford, MA, United States) are installed with integrated Intelligent Quality Management (iQM(®)), which automatically identify and log pre-analytical errors. All blood gas analyzers are connected to the company intranet and interfaced with the GEM Web Plus (Werfen Instrumentation Laboratory, Bedford, MA, United States) data management information system, which allows the core laboratory to remotely supervise all decentralized POC stations. The operator-dependent process NC were expressed in terms of absolute and relative proportions (percentiles and percentage changes). For performance evaluation, the Mann–Whitney U test, Chi-squared test and Six-Sigma Metric calculation for performance classification were performed. Results: In the COVID period, 31,364 blood gas tests were performed vs. 16,632 tests in the pre-COVID period. The NC related to the suitability of the EGA sample and manageable by the operators were totals of 652 (3.9%) and 749 (2.4%), respectively, in the pre-COVID and COVID periods. The pre-analytical phase IQs used did not show statistically significant differences in the two periods evaluated. The Sigma evaluation did not show an increase in error rates. Conclusions: Considering the increase in the number of EGAs performed in the two periods, the training procedures performed by the core laboratory staff were effective; the clinical users of the POC complied with the indications and procedures shared with the core laboratory without increasing the operator-dependent NCs. Furthermore, the core laboratory developed monitoring activities capable of guaranteeing the maintenance of the pre-analytical quality.
format Online
Article
Text
id pubmed-10047429
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100474292023-03-29 Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic Brescia, Vincenzo Varraso, Lucia Antonucci, Mariantonietta Lovero, Roberto Schirinzi, Annalisa Mascolo, Elisa Di Serio, Francesca Diagnostics (Basel) Article Aim of the study: We evaluated and compared blood gas analysis (EGA) non-conformities (NC) considered operator-dependent performed in Point-Of-Care (POC) analyzer as quality indicators (IQ) of the pre-analytical phase. To this end, four different NC registered in the resuscitation departments of the Hospital Polyclinic Bari from the beginning of the pandemic (March 2020) until February 2022 were evaluated. The results obtained were compared with those recorded in the pre-COVID period (March 2018–February 2020) to check if there were differences in number and type. Material and methods: GEM 4000 series blood gas analyzers (Instrumentation Laboratory, Bedford, MA, United States) are installed with integrated Intelligent Quality Management (iQM(®)), which automatically identify and log pre-analytical errors. All blood gas analyzers are connected to the company intranet and interfaced with the GEM Web Plus (Werfen Instrumentation Laboratory, Bedford, MA, United States) data management information system, which allows the core laboratory to remotely supervise all decentralized POC stations. The operator-dependent process NC were expressed in terms of absolute and relative proportions (percentiles and percentage changes). For performance evaluation, the Mann–Whitney U test, Chi-squared test and Six-Sigma Metric calculation for performance classification were performed. Results: In the COVID period, 31,364 blood gas tests were performed vs. 16,632 tests in the pre-COVID period. The NC related to the suitability of the EGA sample and manageable by the operators were totals of 652 (3.9%) and 749 (2.4%), respectively, in the pre-COVID and COVID periods. The pre-analytical phase IQs used did not show statistically significant differences in the two periods evaluated. The Sigma evaluation did not show an increase in error rates. Conclusions: Considering the increase in the number of EGAs performed in the two periods, the training procedures performed by the core laboratory staff were effective; the clinical users of the POC complied with the indications and procedures shared with the core laboratory without increasing the operator-dependent NCs. Furthermore, the core laboratory developed monitoring activities capable of guaranteeing the maintenance of the pre-analytical quality. MDPI 2023-03-09 /pmc/articles/PMC10047429/ /pubmed/36980352 http://dx.doi.org/10.3390/diagnostics13061044 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Brescia, Vincenzo
Varraso, Lucia
Antonucci, Mariantonietta
Lovero, Roberto
Schirinzi, Annalisa
Mascolo, Elisa
Di Serio, Francesca
Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic
title Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic
title_full Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic
title_fullStr Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic
title_full_unstemmed Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic
title_short Analysis of Quality Indicators of the Pre-Analytical Phase on Blood Gas Analyzers, Point-Of-Care Analyzer in the Period of the COVID-19 Pandemic
title_sort analysis of quality indicators of the pre-analytical phase on blood gas analyzers, point-of-care analyzer in the period of the covid-19 pandemic
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10047429/
https://www.ncbi.nlm.nih.gov/pubmed/36980352
http://dx.doi.org/10.3390/diagnostics13061044
work_keys_str_mv AT bresciavincenzo analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic
AT varrasolucia analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic
AT antonuccimariantonietta analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic
AT loveroroberto analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic
AT schirinziannalisa analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic
AT mascoloelisa analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic
AT diseriofrancesca analysisofqualityindicatorsofthepreanalyticalphaseonbloodgasanalyzerspointofcareanalyzerintheperiodofthecovid19pandemic