Cargando…

Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation

A traction transformer with narrow oil channels is usually cooled with the ODAF or “Oil Directed Air Forced” method, where its temperature greatly depends on the Joule heat of windings, the conjugate heat transfer in the transformer, and the secondary heat release via oil cooler, together with the o...

Descripción completa

Detalles Bibliográficos
Autores principales: You, Yonghua, Shao, Kun, Yi, Zhengming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10048119/
https://www.ncbi.nlm.nih.gov/pubmed/36981345
http://dx.doi.org/10.3390/e25030457
_version_ 1785014100319797248
author You, Yonghua
Shao, Kun
Yi, Zhengming
author_facet You, Yonghua
Shao, Kun
Yi, Zhengming
author_sort You, Yonghua
collection PubMed
description A traction transformer with narrow oil channels is usually cooled with the ODAF or “Oil Directed Air Forced” method, where its temperature greatly depends on the Joule heat of windings, the conjugate heat transfer in the transformer, and the secondary heat release via oil cooler, together with the oil flowrate generated by oil pump. Neither the thermal–electric analogy nor the CFD simulation approach is qualified to predict the temporal and spatial temperature variations in this type of transformer. In the current work, the distributed parameter models are built for traction transformers and oil coolers with the assumption of a one-dimensional temperature field in the oil flow direction, respectively. Then, the two models are combined with the lumped parameter ones of oil pumps and pipes via the flow rate, temperature and pressure continuities at their interfaces, resulting in the derivation of the dynamic heat dissipation model of oil-directed and air-forced traction transformers. Additionally, an efficient algorithm is proposed for its numerical solution, and the temperature rise experiment is performed for model validation. Finally, the fundamental of dynamic heat dissipation in traction transformers is investigated with the current numerical model and the effects of ambient temperature are studied.
format Online
Article
Text
id pubmed-10048119
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100481192023-03-29 Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation You, Yonghua Shao, Kun Yi, Zhengming Entropy (Basel) Article A traction transformer with narrow oil channels is usually cooled with the ODAF or “Oil Directed Air Forced” method, where its temperature greatly depends on the Joule heat of windings, the conjugate heat transfer in the transformer, and the secondary heat release via oil cooler, together with the oil flowrate generated by oil pump. Neither the thermal–electric analogy nor the CFD simulation approach is qualified to predict the temporal and spatial temperature variations in this type of transformer. In the current work, the distributed parameter models are built for traction transformers and oil coolers with the assumption of a one-dimensional temperature field in the oil flow direction, respectively. Then, the two models are combined with the lumped parameter ones of oil pumps and pipes via the flow rate, temperature and pressure continuities at their interfaces, resulting in the derivation of the dynamic heat dissipation model of oil-directed and air-forced traction transformers. Additionally, an efficient algorithm is proposed for its numerical solution, and the temperature rise experiment is performed for model validation. Finally, the fundamental of dynamic heat dissipation in traction transformers is investigated with the current numerical model and the effects of ambient temperature are studied. MDPI 2023-03-06 /pmc/articles/PMC10048119/ /pubmed/36981345 http://dx.doi.org/10.3390/e25030457 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
You, Yonghua
Shao, Kun
Yi, Zhengming
Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
title Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
title_full Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
title_fullStr Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
title_full_unstemmed Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
title_short Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
title_sort dynamic heat dissipation model of distributed parameters for oil-directed and air-forced traction transformers and its experimental validation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10048119/
https://www.ncbi.nlm.nih.gov/pubmed/36981345
http://dx.doi.org/10.3390/e25030457
work_keys_str_mv AT youyonghua dynamicheatdissipationmodelofdistributedparametersforoildirectedandairforcedtractiontransformersanditsexperimentalvalidation
AT shaokun dynamicheatdissipationmodelofdistributedparametersforoildirectedandairforcedtractiontransformersanditsexperimentalvalidation
AT yizhengming dynamicheatdissipationmodelofdistributedparametersforoildirectedandairforcedtractiontransformersanditsexperimentalvalidation