Cargando…
Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard
Nuclear medicine procedures play an important role in medical diagnostics and therapy. They are related to the use of ionizing radiation, which affects the radiological exposure of all of the persons involved in their performance. The goal of the study was to estimate the doses associated with the p...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10049529/ https://www.ncbi.nlm.nih.gov/pubmed/36982115 http://dx.doi.org/10.3390/ijerph20065206 |
_version_ | 1785014480406577152 |
---|---|
author | Matusiak, Katarzyna Wolna, Justyna Jung, Aleksandra Sadowski, Leszek Pawlus, Jolanta |
author_facet | Matusiak, Katarzyna Wolna, Justyna Jung, Aleksandra Sadowski, Leszek Pawlus, Jolanta |
author_sort | Matusiak, Katarzyna |
collection | PubMed |
description | Nuclear medicine procedures play an important role in medical diagnostics and therapy. They are related to the use of ionizing radiation, which affects the radiological exposure of all of the persons involved in their performance. The goal of the study was to estimate the doses associated with the performance of various nuclear medicine procedures in order to optimize workload management. The analysis was performed for 158 myocardial perfusion scintigraphy procedures, 24 bone scintigraphies, 9 thyroid scintigraphies (6 with use of (131)I and 3 with (99m)Tc), 5 parathyroid glands and 5 renal scintigraphies. In this evaluation, two possible locations of thermoluminescent detectors, used for measurements, were taken into consideration: in the control room and directly next to the patient. It was shown how the radiological exposure varies depending on the performed procedure. For high activity procedures, ambient dose equivalent registered in the control room reached the level over 50% of allowed dose limit. For example, ambient dose equivalent obtained in control room when performing bone scintigraphy only was 1.13 ± 0.3 mSv. It is 68% of calculated dose limit in the examined time span. It has been shown that risk associated with nuclear medicine procedures is influenced not only by the type of procedure, but also by the frequency of their performance and compliance with the ALARA principle. Myocardial perfusion scintigraphy accounted for 79% of all evaluated procedures. The use of radiation shielding reduced the obtained doses from 14.7 ± 2.1 mSv in patient’s vicinity to 1.47 ± 0.6 mSv behind the shielding. By comparing the results obtained for procedures and dose limits established by Polish Ministry of Health, it is possible to estimate what should be the optimal division of duties between staff, so that everyone receives similar doses. |
format | Online Article Text |
id | pubmed-10049529 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100495292023-03-29 Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard Matusiak, Katarzyna Wolna, Justyna Jung, Aleksandra Sadowski, Leszek Pawlus, Jolanta Int J Environ Res Public Health Article Nuclear medicine procedures play an important role in medical diagnostics and therapy. They are related to the use of ionizing radiation, which affects the radiological exposure of all of the persons involved in their performance. The goal of the study was to estimate the doses associated with the performance of various nuclear medicine procedures in order to optimize workload management. The analysis was performed for 158 myocardial perfusion scintigraphy procedures, 24 bone scintigraphies, 9 thyroid scintigraphies (6 with use of (131)I and 3 with (99m)Tc), 5 parathyroid glands and 5 renal scintigraphies. In this evaluation, two possible locations of thermoluminescent detectors, used for measurements, were taken into consideration: in the control room and directly next to the patient. It was shown how the radiological exposure varies depending on the performed procedure. For high activity procedures, ambient dose equivalent registered in the control room reached the level over 50% of allowed dose limit. For example, ambient dose equivalent obtained in control room when performing bone scintigraphy only was 1.13 ± 0.3 mSv. It is 68% of calculated dose limit in the examined time span. It has been shown that risk associated with nuclear medicine procedures is influenced not only by the type of procedure, but also by the frequency of their performance and compliance with the ALARA principle. Myocardial perfusion scintigraphy accounted for 79% of all evaluated procedures. The use of radiation shielding reduced the obtained doses from 14.7 ± 2.1 mSv in patient’s vicinity to 1.47 ± 0.6 mSv behind the shielding. By comparing the results obtained for procedures and dose limits established by Polish Ministry of Health, it is possible to estimate what should be the optimal division of duties between staff, so that everyone receives similar doses. MDPI 2023-03-15 /pmc/articles/PMC10049529/ /pubmed/36982115 http://dx.doi.org/10.3390/ijerph20065206 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Matusiak, Katarzyna Wolna, Justyna Jung, Aleksandra Sadowski, Leszek Pawlus, Jolanta Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard |
title | Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard |
title_full | Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard |
title_fullStr | Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard |
title_full_unstemmed | Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard |
title_short | Impact of the Frequency and Type of Procedures Performed in Nuclear Medicine Units on the Expected Radiological Hazard |
title_sort | impact of the frequency and type of procedures performed in nuclear medicine units on the expected radiological hazard |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10049529/ https://www.ncbi.nlm.nih.gov/pubmed/36982115 http://dx.doi.org/10.3390/ijerph20065206 |
work_keys_str_mv | AT matusiakkatarzyna impactofthefrequencyandtypeofproceduresperformedinnuclearmedicineunitsontheexpectedradiologicalhazard AT wolnajustyna impactofthefrequencyandtypeofproceduresperformedinnuclearmedicineunitsontheexpectedradiologicalhazard AT jungaleksandra impactofthefrequencyandtypeofproceduresperformedinnuclearmedicineunitsontheexpectedradiologicalhazard AT sadowskileszek impactofthefrequencyandtypeofproceduresperformedinnuclearmedicineunitsontheexpectedradiologicalhazard AT pawlusjolanta impactofthefrequencyandtypeofproceduresperformedinnuclearmedicineunitsontheexpectedradiologicalhazard |