Cargando…

Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements

BACKGROUND: Many radiographic lower limb alignment  measurements are dependent on patients’ position, which makes a standardised image acquisition of long-leg radiographs (LLRs) essential for valid measurements. The purpose of this study was to investigate the influence of rotation and flexion of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Brunner, Josef, Jörgens, Maximilian, Weigert, Maximilian, Kümpel, Hannah, Degen, Nikolaus, Fuermetz, Julian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10050026/
https://www.ncbi.nlm.nih.gov/pubmed/36595052
http://dx.doi.org/10.1007/s00167-022-07302-x
_version_ 1785014590565777408
author Brunner, Josef
Jörgens, Maximilian
Weigert, Maximilian
Kümpel, Hannah
Degen, Nikolaus
Fuermetz, Julian
author_facet Brunner, Josef
Jörgens, Maximilian
Weigert, Maximilian
Kümpel, Hannah
Degen, Nikolaus
Fuermetz, Julian
author_sort Brunner, Josef
collection PubMed
description BACKGROUND: Many radiographic lower limb alignment  measurements are dependent on patients’ position, which makes a standardised image acquisition of long-leg radiographs (LLRs) essential for valid measurements. The purpose of this study was to investigate the influence of rotation and flexion of the lower limb on common radiological alignment parameters using three-dimensional (3D) simulation. METHODS: Joint angles and alignment parameters of 3D lower limb bone models (n = 60), generated from computed tomography (CT) scans, were assessed and projected into the coronal plane to mimic radiographic imaging. Bone models were subsequently rotated around the longitudinal mechanical axis up to 15° inward/outward and additionally flexed along the femoral intercondylar axis up to 30°. This resulted in 28 combinations of rotation and flexion for each leg. The results were statistically analysed on a descriptive level and using a linear mixed effects model. RESULTS: A total of 1680 simulations were performed. Mechanical axis deviation (MAD) revealed a medial deviation with increasing internal rotation and a lateral deviation with increasing external rotation. This effect increased significantly (p < 0.05) with combined flexion up to 30° flexion (− 25.4 mm to 25.2 mm). With the knee extended, the mean deviation of hip–knee–ankle angle (HKA) was small over all rotational steps but increased toward more varus/valgus when combined with flexion (8.4° to − 8.5°). Rotation alone changed the medial proximal tibial angle (MPTA) and the mechanical lateral distal femoral angle (mLDFA) in opposite directions, and the effects increased significantly (p < 0.05) when flexion was present. CONCLUSIONS: Axial rotation and flexion of the 3D lower limb has a huge impact on the projected two-dimensional alignment measurements in the coronal plane. The observed effects were small for isolated rotation or flexion, but became pronounced and clinically relevant when there was a combination of both. This must be considered when evaluating X-ray images. Extension deficits of the knee make LLR prone to error and this calls into question direct postoperative alignment controls. LEVEL OF EVIDENCE: III (retrospective cohort study). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00167-022-07302-x.
format Online
Article
Text
id pubmed-10050026
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-100500262023-03-30 Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements Brunner, Josef Jörgens, Maximilian Weigert, Maximilian Kümpel, Hannah Degen, Nikolaus Fuermetz, Julian Knee Surg Sports Traumatol Arthrosc Knee BACKGROUND: Many radiographic lower limb alignment  measurements are dependent on patients’ position, which makes a standardised image acquisition of long-leg radiographs (LLRs) essential for valid measurements. The purpose of this study was to investigate the influence of rotation and flexion of the lower limb on common radiological alignment parameters using three-dimensional (3D) simulation. METHODS: Joint angles and alignment parameters of 3D lower limb bone models (n = 60), generated from computed tomography (CT) scans, were assessed and projected into the coronal plane to mimic radiographic imaging. Bone models were subsequently rotated around the longitudinal mechanical axis up to 15° inward/outward and additionally flexed along the femoral intercondylar axis up to 30°. This resulted in 28 combinations of rotation and flexion for each leg. The results were statistically analysed on a descriptive level and using a linear mixed effects model. RESULTS: A total of 1680 simulations were performed. Mechanical axis deviation (MAD) revealed a medial deviation with increasing internal rotation and a lateral deviation with increasing external rotation. This effect increased significantly (p < 0.05) with combined flexion up to 30° flexion (− 25.4 mm to 25.2 mm). With the knee extended, the mean deviation of hip–knee–ankle angle (HKA) was small over all rotational steps but increased toward more varus/valgus when combined with flexion (8.4° to − 8.5°). Rotation alone changed the medial proximal tibial angle (MPTA) and the mechanical lateral distal femoral angle (mLDFA) in opposite directions, and the effects increased significantly (p < 0.05) when flexion was present. CONCLUSIONS: Axial rotation and flexion of the 3D lower limb has a huge impact on the projected two-dimensional alignment measurements in the coronal plane. The observed effects were small for isolated rotation or flexion, but became pronounced and clinically relevant when there was a combination of both. This must be considered when evaluating X-ray images. Extension deficits of the knee make LLR prone to error and this calls into question direct postoperative alignment controls. LEVEL OF EVIDENCE: III (retrospective cohort study). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00167-022-07302-x. Springer Berlin Heidelberg 2023-01-03 2023 /pmc/articles/PMC10050026/ /pubmed/36595052 http://dx.doi.org/10.1007/s00167-022-07302-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Knee
Brunner, Josef
Jörgens, Maximilian
Weigert, Maximilian
Kümpel, Hannah
Degen, Nikolaus
Fuermetz, Julian
Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements
title Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements
title_full Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements
title_fullStr Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements
title_full_unstemmed Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements
title_short Significant changes in lower limb alignment due to flexion and rotation—a systematic 3D simulation of radiographic measurements
title_sort significant changes in lower limb alignment due to flexion and rotation—a systematic 3d simulation of radiographic measurements
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10050026/
https://www.ncbi.nlm.nih.gov/pubmed/36595052
http://dx.doi.org/10.1007/s00167-022-07302-x
work_keys_str_mv AT brunnerjosef significantchangesinlowerlimbalignmentduetoflexionandrotationasystematic3dsimulationofradiographicmeasurements
AT jorgensmaximilian significantchangesinlowerlimbalignmentduetoflexionandrotationasystematic3dsimulationofradiographicmeasurements
AT weigertmaximilian significantchangesinlowerlimbalignmentduetoflexionandrotationasystematic3dsimulationofradiographicmeasurements
AT kumpelhannah significantchangesinlowerlimbalignmentduetoflexionandrotationasystematic3dsimulationofradiographicmeasurements
AT degennikolaus significantchangesinlowerlimbalignmentduetoflexionandrotationasystematic3dsimulationofradiographicmeasurements
AT fuermetzjulian significantchangesinlowerlimbalignmentduetoflexionandrotationasystematic3dsimulationofradiographicmeasurements