NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR

(1) Background: A well-established Boron Neutron Capture Therapy (BNCT) facility includes many essential systems, which are the epithermal neutron beam system, on-line monitoring system (OMS), QA/QC (quality assurance or quality control) system, boron concentration (BC) measurement system, and treat...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yu-Shiang, Peir, Jinn-Jer, Wu, Chuan-Jen, Wang, Mei-Ya, Chen, Yi-Wei, Lee, Jia-Cheng, Chou, Fong-In
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10051313/
https://www.ncbi.nlm.nih.gov/pubmed/36983956
http://dx.doi.org/10.3390/life13030800
_version_ 1785014855536738304
author Huang, Yu-Shiang
Peir, Jinn-Jer
Wu, Chuan-Jen
Wang, Mei-Ya
Chen, Yi-Wei
Lee, Jia-Cheng
Chou, Fong-In
author_facet Huang, Yu-Shiang
Peir, Jinn-Jer
Wu, Chuan-Jen
Wang, Mei-Ya
Chen, Yi-Wei
Lee, Jia-Cheng
Chou, Fong-In
author_sort Huang, Yu-Shiang
collection PubMed
description (1) Background: A well-established Boron Neutron Capture Therapy (BNCT) facility includes many essential systems, which are the epithermal neutron beam system, on-line monitoring system (OMS), QA/QC (quality assurance or quality control) system, boron concentration (BC) measurement system, and treatment planning system (TPS). Accurate data transmission, monitoring, and deposition among these systems are of vital importance before, during, and after clinical, animal, and cell BNCT irradiation. This work developed a novel integrated platform NeuTHOR Station (NeuTHORS) for BNCT at Tsing Hua Open-pool Reactor (THOR). Apart from the data of the OMS and QA/QC system, the data of BC and TPS can be loaded on NeuTHORS before BNCT clinical, animal, and cell irradiation. (2) Methods: A multi-paradigm computer programming language c# (c sharp) was used to develop the integrated platform NeuTHORS. The design of NeuTHORS is based on the standard procedures of BNCT treatment or experiment at THOR. Moreover, parallel testing with OMS-BNCT (the former OMS) and QA/QC of THOR was also performed for more than 70 times to verify the validation of NeuTHORS. (3) Results: According to the comparisons of the output, NeuTHORS and OMS-BNCT and QA/QC of THOR show very good consistency. NeuTHORS is now installed on an industrial PC (IPC) and successfully performs the monitoring of BNCT Treatment at THOR. Patients’ f BC and TPS data are also input into NeuTHORS and stored on IPC through an internal network from BC measurement room and TPS physicist. Therefore, the treatment data of each patient can be instantaneously established after each BNCT treatment for further study on BNCT. NeuTHORS can also be applied on data acquisition for a BNCT-related study, especially for animal or cell irradiation experiments. (4) Conclusions: A novel integrated platform NeuTHOR Station for monitoring BNCT clinical treatment and animal and cell irradiation study has been successfully established at THOR. With this platform, BNCT radiobiology investigations will be efficiently performed and a thorough data storage and analysis system of BNCT treatments or experiments can thus be systematically built up for the further investigation of BNCT at THOR.
format Online
Article
Text
id pubmed-10051313
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100513132023-03-30 NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR Huang, Yu-Shiang Peir, Jinn-Jer Wu, Chuan-Jen Wang, Mei-Ya Chen, Yi-Wei Lee, Jia-Cheng Chou, Fong-In Life (Basel) Article (1) Background: A well-established Boron Neutron Capture Therapy (BNCT) facility includes many essential systems, which are the epithermal neutron beam system, on-line monitoring system (OMS), QA/QC (quality assurance or quality control) system, boron concentration (BC) measurement system, and treatment planning system (TPS). Accurate data transmission, monitoring, and deposition among these systems are of vital importance before, during, and after clinical, animal, and cell BNCT irradiation. This work developed a novel integrated platform NeuTHOR Station (NeuTHORS) for BNCT at Tsing Hua Open-pool Reactor (THOR). Apart from the data of the OMS and QA/QC system, the data of BC and TPS can be loaded on NeuTHORS before BNCT clinical, animal, and cell irradiation. (2) Methods: A multi-paradigm computer programming language c# (c sharp) was used to develop the integrated platform NeuTHORS. The design of NeuTHORS is based on the standard procedures of BNCT treatment or experiment at THOR. Moreover, parallel testing with OMS-BNCT (the former OMS) and QA/QC of THOR was also performed for more than 70 times to verify the validation of NeuTHORS. (3) Results: According to the comparisons of the output, NeuTHORS and OMS-BNCT and QA/QC of THOR show very good consistency. NeuTHORS is now installed on an industrial PC (IPC) and successfully performs the monitoring of BNCT Treatment at THOR. Patients’ f BC and TPS data are also input into NeuTHORS and stored on IPC through an internal network from BC measurement room and TPS physicist. Therefore, the treatment data of each patient can be instantaneously established after each BNCT treatment for further study on BNCT. NeuTHORS can also be applied on data acquisition for a BNCT-related study, especially for animal or cell irradiation experiments. (4) Conclusions: A novel integrated platform NeuTHOR Station for monitoring BNCT clinical treatment and animal and cell irradiation study has been successfully established at THOR. With this platform, BNCT radiobiology investigations will be efficiently performed and a thorough data storage and analysis system of BNCT treatments or experiments can thus be systematically built up for the further investigation of BNCT at THOR. MDPI 2023-03-15 /pmc/articles/PMC10051313/ /pubmed/36983956 http://dx.doi.org/10.3390/life13030800 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Yu-Shiang
Peir, Jinn-Jer
Wu, Chuan-Jen
Wang, Mei-Ya
Chen, Yi-Wei
Lee, Jia-Cheng
Chou, Fong-In
NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR
title NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR
title_full NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR
title_fullStr NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR
title_full_unstemmed NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR
title_short NeuTHOR Station—A Novel Integrated Platform for Monitoring BNCT Clinical Treatment, Animal and Cell Irradiation Study at THOR
title_sort neuthor station—a novel integrated platform for monitoring bnct clinical treatment, animal and cell irradiation study at thor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10051313/
https://www.ncbi.nlm.nih.gov/pubmed/36983956
http://dx.doi.org/10.3390/life13030800
work_keys_str_mv AT huangyushiang neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor
AT peirjinnjer neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor
AT wuchuanjen neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor
AT wangmeiya neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor
AT chenyiwei neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor
AT leejiacheng neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor
AT choufongin neuthorstationanovelintegratedplatformformonitoringbnctclinicaltreatmentanimalandcellirradiationstudyatthor