Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis

Twelve drugs containing sildenafil compounds (sildenafil citrate and sildenafil base) were examined using X-ray studies and thermal analysis. According to the manufacturer’s information, the presence of sildenafil was confirmed in all investigated drugs. The positions of diffraction lines (value of...

Descripción completa

Detalles Bibliográficos
Autores principales: Jendrzejewska, Izabela, Goryczka, Tomasz, Pietrasik, Ewa, Klimontko, Joanna, Jampilek, Josef
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10051464/
https://www.ncbi.nlm.nih.gov/pubmed/36985604
http://dx.doi.org/10.3390/molecules28062632
_version_ 1785014893300154368
author Jendrzejewska, Izabela
Goryczka, Tomasz
Pietrasik, Ewa
Klimontko, Joanna
Jampilek, Josef
author_facet Jendrzejewska, Izabela
Goryczka, Tomasz
Pietrasik, Ewa
Klimontko, Joanna
Jampilek, Josef
author_sort Jendrzejewska, Izabela
collection PubMed
description Twelve drugs containing sildenafil compounds (sildenafil citrate and sildenafil base) were examined using X-ray studies and thermal analysis. According to the manufacturer’s information, the presence of sildenafil was confirmed in all investigated drugs. The positions of diffraction lines (value of 2θ angle) agree with the patterns presented in the ICDD database, Release 2018 (ICDD—International Centre of Diffraction Data). The difference expresses the agreement in the position of the diffraction line between the tested substance and the standard. A good agreement is when this difference is less than 0.2°. The values of interplanar distances d(hkl) are also compatible with the ICDD database. It indicated that the drug examined was genuine. Because all drugs are mixtures of different substances (API and excipients), the various diffraction line intensities were detected in all observed X-ray images for the tested drugs. The intensity of the diffraction line depends on many factors, like the amount of substance, coexisting phases, and mass absorption coefficient of the mixture. The thermal analysis confirmed the results obtained by the X-ray study. On DSC curves, the endothermic peaks for sildenafil compounds were observed. The determined melting points of sildenafil compounds corresponded to the values available in the literature. The results gathered by connecting two methods, X-ray study and thermal analysis, can help identify irregularities that may exist in pharmaceutical specimens, e.g., distinguishing genuine from counterfeit products, the presence of a correct polymorph, a lack of active substance, an inaccurate amount of the active substance, or excipients in the tested drug.
format Online
Article
Text
id pubmed-10051464
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100514642023-03-30 Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis Jendrzejewska, Izabela Goryczka, Tomasz Pietrasik, Ewa Klimontko, Joanna Jampilek, Josef Molecules Article Twelve drugs containing sildenafil compounds (sildenafil citrate and sildenafil base) were examined using X-ray studies and thermal analysis. According to the manufacturer’s information, the presence of sildenafil was confirmed in all investigated drugs. The positions of diffraction lines (value of 2θ angle) agree with the patterns presented in the ICDD database, Release 2018 (ICDD—International Centre of Diffraction Data). The difference expresses the agreement in the position of the diffraction line between the tested substance and the standard. A good agreement is when this difference is less than 0.2°. The values of interplanar distances d(hkl) are also compatible with the ICDD database. It indicated that the drug examined was genuine. Because all drugs are mixtures of different substances (API and excipients), the various diffraction line intensities were detected in all observed X-ray images for the tested drugs. The intensity of the diffraction line depends on many factors, like the amount of substance, coexisting phases, and mass absorption coefficient of the mixture. The thermal analysis confirmed the results obtained by the X-ray study. On DSC curves, the endothermic peaks for sildenafil compounds were observed. The determined melting points of sildenafil compounds corresponded to the values available in the literature. The results gathered by connecting two methods, X-ray study and thermal analysis, can help identify irregularities that may exist in pharmaceutical specimens, e.g., distinguishing genuine from counterfeit products, the presence of a correct polymorph, a lack of active substance, an inaccurate amount of the active substance, or excipients in the tested drug. MDPI 2023-03-14 /pmc/articles/PMC10051464/ /pubmed/36985604 http://dx.doi.org/10.3390/molecules28062632 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jendrzejewska, Izabela
Goryczka, Tomasz
Pietrasik, Ewa
Klimontko, Joanna
Jampilek, Josef
Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
title Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
title_full Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
title_fullStr Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
title_full_unstemmed Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
title_short Identification of Sildenafil Compound in Selected Drugs Using X-ray Study and Thermal Analysis
title_sort identification of sildenafil compound in selected drugs using x-ray study and thermal analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10051464/
https://www.ncbi.nlm.nih.gov/pubmed/36985604
http://dx.doi.org/10.3390/molecules28062632
work_keys_str_mv AT jendrzejewskaizabela identificationofsildenafilcompoundinselecteddrugsusingxraystudyandthermalanalysis
AT goryczkatomasz identificationofsildenafilcompoundinselecteddrugsusingxraystudyandthermalanalysis
AT pietrasikewa identificationofsildenafilcompoundinselecteddrugsusingxraystudyandthermalanalysis
AT klimontkojoanna identificationofsildenafilcompoundinselecteddrugsusingxraystudyandthermalanalysis
AT jampilekjosef identificationofsildenafilcompoundinselecteddrugsusingxraystudyandthermalanalysis