Cargando…

New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test

Nowadays, with the increase in the rhythm of life, the relevance of using express diagnostics methods for human health state estimation has significantly increased. We present a new express diagnostics method based on non-invasive measurements (the pulse wave shape, heart rate, blood pressure, and o...

Descripción completa

Detalles Bibliográficos
Autores principales: Davydov, Roman, Zaitceva, Anna, Davydov, Vadim, Isakova, Daria, Mazing, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10052938/
https://www.ncbi.nlm.nih.gov/pubmed/36983623
http://dx.doi.org/10.3390/jpm13030443
_version_ 1785015281268031488
author Davydov, Roman
Zaitceva, Anna
Davydov, Vadim
Isakova, Daria
Mazing, Maria
author_facet Davydov, Roman
Zaitceva, Anna
Davydov, Vadim
Isakova, Daria
Mazing, Maria
author_sort Davydov, Roman
collection PubMed
description Nowadays, with the increase in the rhythm of life, the relevance of using express diagnostics methods for human health state estimation has significantly increased. We present a new express diagnostics method based on non-invasive measurements (the pulse wave shape, heart rate, blood pressure, and oxygen saturation of blood vessels and tissues). A feature of these measurements is that they can be carried out both in the hospital and at home. The new compact and portable optical hardware–software complex has been developed to measure tissue oxygen saturation. This complex makes it possible to reduce the measurement time from 60 min to 7–8 min, which reduces the likelihood of artifacts in the measurement process and increases its reliability. A new technique has been developed to carry out these measurements. A new optical sensor based on a line of charge-coupled devices has been developed to register a pulse wave in the far peripheral zone. The developed new technique for processing the pulse waveform and data on the oxygen saturation of hemoglobin in the blood and tissues allows a person to obtain additional information about their state of health independently. It will help to make conclusions about taking the necessary measures. This additional information allows the attending physician to provide more effective control over the course of treatment of the patient at any time since the methods of express diagnostics proposed by us have no restrictions on the number of applications. The functional state of more than 300 patients was studied. The results of various measurements are presented.
format Online
Article
Text
id pubmed-10052938
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100529382023-03-30 New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test Davydov, Roman Zaitceva, Anna Davydov, Vadim Isakova, Daria Mazing, Maria J Pers Med Article Nowadays, with the increase in the rhythm of life, the relevance of using express diagnostics methods for human health state estimation has significantly increased. We present a new express diagnostics method based on non-invasive measurements (the pulse wave shape, heart rate, blood pressure, and oxygen saturation of blood vessels and tissues). A feature of these measurements is that they can be carried out both in the hospital and at home. The new compact and portable optical hardware–software complex has been developed to measure tissue oxygen saturation. This complex makes it possible to reduce the measurement time from 60 min to 7–8 min, which reduces the likelihood of artifacts in the measurement process and increases its reliability. A new technique has been developed to carry out these measurements. A new optical sensor based on a line of charge-coupled devices has been developed to register a pulse wave in the far peripheral zone. The developed new technique for processing the pulse waveform and data on the oxygen saturation of hemoglobin in the blood and tissues allows a person to obtain additional information about their state of health independently. It will help to make conclusions about taking the necessary measures. This additional information allows the attending physician to provide more effective control over the course of treatment of the patient at any time since the methods of express diagnostics proposed by us have no restrictions on the number of applications. The functional state of more than 300 patients was studied. The results of various measurements are presented. MDPI 2023-02-28 /pmc/articles/PMC10052938/ /pubmed/36983623 http://dx.doi.org/10.3390/jpm13030443 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Davydov, Roman
Zaitceva, Anna
Davydov, Vadim
Isakova, Daria
Mazing, Maria
New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test
title New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test
title_full New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test
title_fullStr New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test
title_full_unstemmed New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test
title_short New Methodology of Human Health Express Diagnostics Based on Pulse Wave Measurements and Occlusion Test
title_sort new methodology of human health express diagnostics based on pulse wave measurements and occlusion test
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10052938/
https://www.ncbi.nlm.nih.gov/pubmed/36983623
http://dx.doi.org/10.3390/jpm13030443
work_keys_str_mv AT davydovroman newmethodologyofhumanhealthexpressdiagnosticsbasedonpulsewavemeasurementsandocclusiontest
AT zaitcevaanna newmethodologyofhumanhealthexpressdiagnosticsbasedonpulsewavemeasurementsandocclusiontest
AT davydovvadim newmethodologyofhumanhealthexpressdiagnosticsbasedonpulsewavemeasurementsandocclusiontest
AT isakovadaria newmethodologyofhumanhealthexpressdiagnosticsbasedonpulsewavemeasurementsandocclusiontest
AT mazingmaria newmethodologyofhumanhealthexpressdiagnosticsbasedonpulsewavemeasurementsandocclusiontest