Cargando…

Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images

One of the crucial tasks for the planning of surgery of the iliosacral joint is placing an iliosacral screw with the goal of fixing broken parts of the pelvis. Tracking of proper screw trajectory is usually done in the preoperative phase by the acquisition of X-ray images under different angles, whi...

Descripción completa

Detalles Bibliográficos
Autores principales: Benda, Vojtech, Kubicek, Jan, Madeja, Roman, Oczka, David, Cerny, Martin, Dostalova, Kamila
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10054889/
https://www.ncbi.nlm.nih.gov/pubmed/36983141
http://dx.doi.org/10.3390/jcm12062138
_version_ 1785015780551688192
author Benda, Vojtech
Kubicek, Jan
Madeja, Roman
Oczka, David
Cerny, Martin
Dostalova, Kamila
author_facet Benda, Vojtech
Kubicek, Jan
Madeja, Roman
Oczka, David
Cerny, Martin
Dostalova, Kamila
author_sort Benda, Vojtech
collection PubMed
description One of the crucial tasks for the planning of surgery of the iliosacral joint is placing an iliosacral screw with the goal of fixing broken parts of the pelvis. Tracking of proper screw trajectory is usually done in the preoperative phase by the acquisition of X-ray images under different angles, which guide the surgeons to perform surgery. This approach is standardly complicated due to the investigation of 2D X-ray images not showing spatial perspective. Therefore, in this pilot study, we propose complex software tools which are aimed at making a simulation model of reconstructed CT (DDR) images with a virtual iliosacral screw to guide the surgery process. This pilot study presents the testing for two clinical cases to reveal the initial performance and usability of this software in clinical conditions. This model is consequently used for a multiregional registration with reference intraoperative X-ray images to select the slide from the 3D dataset which best fits with reference X-ray. The proposed software solution utilizes input CT slices of the pelvis area to create a segmentation model of individual bone components. Consequently, a model of an iliosacral screw is inserted into this model. In the next step, we propose the software CT2DDR which makes DDR projections with the iliosacral screw. In the last step, we propose a multimodal registration procedure, which performs registration of a selected number of slices with reference X-ray, and based on the Structural Similarity Index (SSIM) and index of correlation, the procedure finds the best match of DDR with X-ray images. In this pilot study, we also provide a comparative analysis of the computational costs of the multimodal registration upon various numbers of DDR slices to show the complex software performance. The proposed complex model has versatile usage for modeling and surgery planning of the pelvis area in fractures of iliosacral joints.
format Online
Article
Text
id pubmed-10054889
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100548892023-03-30 Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images Benda, Vojtech Kubicek, Jan Madeja, Roman Oczka, David Cerny, Martin Dostalova, Kamila J Clin Med Article One of the crucial tasks for the planning of surgery of the iliosacral joint is placing an iliosacral screw with the goal of fixing broken parts of the pelvis. Tracking of proper screw trajectory is usually done in the preoperative phase by the acquisition of X-ray images under different angles, which guide the surgeons to perform surgery. This approach is standardly complicated due to the investigation of 2D X-ray images not showing spatial perspective. Therefore, in this pilot study, we propose complex software tools which are aimed at making a simulation model of reconstructed CT (DDR) images with a virtual iliosacral screw to guide the surgery process. This pilot study presents the testing for two clinical cases to reveal the initial performance and usability of this software in clinical conditions. This model is consequently used for a multiregional registration with reference intraoperative X-ray images to select the slide from the 3D dataset which best fits with reference X-ray. The proposed software solution utilizes input CT slices of the pelvis area to create a segmentation model of individual bone components. Consequently, a model of an iliosacral screw is inserted into this model. In the next step, we propose the software CT2DDR which makes DDR projections with the iliosacral screw. In the last step, we propose a multimodal registration procedure, which performs registration of a selected number of slices with reference X-ray, and based on the Structural Similarity Index (SSIM) and index of correlation, the procedure finds the best match of DDR with X-ray images. In this pilot study, we also provide a comparative analysis of the computational costs of the multimodal registration upon various numbers of DDR slices to show the complex software performance. The proposed complex model has versatile usage for modeling and surgery planning of the pelvis area in fractures of iliosacral joints. MDPI 2023-03-09 /pmc/articles/PMC10054889/ /pubmed/36983141 http://dx.doi.org/10.3390/jcm12062138 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Benda, Vojtech
Kubicek, Jan
Madeja, Roman
Oczka, David
Cerny, Martin
Dostalova, Kamila
Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images
title Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images
title_full Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images
title_fullStr Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images
title_full_unstemmed Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images
title_short Design of Proposed Software System for Prediction of Iliosacral Screw Placement for Iliosacral Joint Injuries Based on X-ray and CT Images
title_sort design of proposed software system for prediction of iliosacral screw placement for iliosacral joint injuries based on x-ray and ct images
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10054889/
https://www.ncbi.nlm.nih.gov/pubmed/36983141
http://dx.doi.org/10.3390/jcm12062138
work_keys_str_mv AT bendavojtech designofproposedsoftwaresystemforpredictionofiliosacralscrewplacementforiliosacraljointinjuriesbasedonxrayandctimages
AT kubicekjan designofproposedsoftwaresystemforpredictionofiliosacralscrewplacementforiliosacraljointinjuriesbasedonxrayandctimages
AT madejaroman designofproposedsoftwaresystemforpredictionofiliosacralscrewplacementforiliosacraljointinjuriesbasedonxrayandctimages
AT oczkadavid designofproposedsoftwaresystemforpredictionofiliosacralscrewplacementforiliosacraljointinjuriesbasedonxrayandctimages
AT cernymartin designofproposedsoftwaresystemforpredictionofiliosacralscrewplacementforiliosacraljointinjuriesbasedonxrayandctimages
AT dostalovakamila designofproposedsoftwaresystemforpredictionofiliosacralscrewplacementforiliosacraljointinjuriesbasedonxrayandctimages