Cargando…
Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry
In this study, we developed a glucose fiber sensor incorporating heterodyne interferometry to measure the phase difference produced by the chemical reaction between glucose and glucose oxidase (GOx). Both theoretical and experimental results showed that the amount of phase variation is inversely pro...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10055821/ https://www.ncbi.nlm.nih.gov/pubmed/36991701 http://dx.doi.org/10.3390/s23062990 |
_version_ | 1785015967971016704 |
---|---|
author | Hsu, Cheng-Chih Chung, Wan-Yu Chang, Chun-Yi Wu, Chyan-Chyi Lee, Cheng-Ling |
author_facet | Hsu, Cheng-Chih Chung, Wan-Yu Chang, Chun-Yi Wu, Chyan-Chyi Lee, Cheng-Ling |
author_sort | Hsu, Cheng-Chih |
collection | PubMed |
description | In this study, we developed a glucose fiber sensor incorporating heterodyne interferometry to measure the phase difference produced by the chemical reaction between glucose and glucose oxidase (GOx). Both theoretical and experimental results showed that the amount of phase variation is inversely proportional to glucose concentration. The proposed method provided a linear measurement range of the glucose concentration from 10 mg/dL to 550 mg/dL. The experimental results indicated that the sensitivity is proportional to the length of the enzymatic glucose sensor, and the optimum resolution can be obtained at a sensor length of 3 cm. The optimum resolution of the proposed method is better than 0.6 mg/dL. Moreover, the proposed sensor demonstrates good repeatability and reliability. The average relative standard deviation (RSD) is better than 10% and satisfied the minimum requirement for point-of-care devices. |
format | Online Article Text |
id | pubmed-10055821 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100558212023-03-30 Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry Hsu, Cheng-Chih Chung, Wan-Yu Chang, Chun-Yi Wu, Chyan-Chyi Lee, Cheng-Ling Sensors (Basel) Article In this study, we developed a glucose fiber sensor incorporating heterodyne interferometry to measure the phase difference produced by the chemical reaction between glucose and glucose oxidase (GOx). Both theoretical and experimental results showed that the amount of phase variation is inversely proportional to glucose concentration. The proposed method provided a linear measurement range of the glucose concentration from 10 mg/dL to 550 mg/dL. The experimental results indicated that the sensitivity is proportional to the length of the enzymatic glucose sensor, and the optimum resolution can be obtained at a sensor length of 3 cm. The optimum resolution of the proposed method is better than 0.6 mg/dL. Moreover, the proposed sensor demonstrates good repeatability and reliability. The average relative standard deviation (RSD) is better than 10% and satisfied the minimum requirement for point-of-care devices. MDPI 2023-03-09 /pmc/articles/PMC10055821/ /pubmed/36991701 http://dx.doi.org/10.3390/s23062990 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hsu, Cheng-Chih Chung, Wan-Yu Chang, Chun-Yi Wu, Chyan-Chyi Lee, Cheng-Ling Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry |
title | Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry |
title_full | Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry |
title_fullStr | Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry |
title_full_unstemmed | Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry |
title_short | Enzymatic Glucose Fiber Sensor for Glucose Concentration Measurement with a Heterodyne Interferometry |
title_sort | enzymatic glucose fiber sensor for glucose concentration measurement with a heterodyne interferometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10055821/ https://www.ncbi.nlm.nih.gov/pubmed/36991701 http://dx.doi.org/10.3390/s23062990 |
work_keys_str_mv | AT hsuchengchih enzymaticglucosefibersensorforglucoseconcentrationmeasurementwithaheterodyneinterferometry AT chungwanyu enzymaticglucosefibersensorforglucoseconcentrationmeasurementwithaheterodyneinterferometry AT changchunyi enzymaticglucosefibersensorforglucoseconcentrationmeasurementwithaheterodyneinterferometry AT wuchyanchyi enzymaticglucosefibersensorforglucoseconcentrationmeasurementwithaheterodyneinterferometry AT leechengling enzymaticglucosefibersensorforglucoseconcentrationmeasurementwithaheterodyneinterferometry |