Cargando…

A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes

Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measurin...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Jinghua, Bader, Dan L., Moser, David, Parker, Daniel J., Forghany, Saeed, Nester, Christopher J., Jiang, Liudi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10056665/
https://www.ncbi.nlm.nih.gov/pubmed/36991838
http://dx.doi.org/10.3390/s23063126
_version_ 1785016179360792576
author Tang, Jinghua
Bader, Dan L.
Moser, David
Parker, Daniel J.
Forghany, Saeed
Nester, Christopher J.
Jiang, Liudi
author_facet Tang, Jinghua
Bader, Dan L.
Moser, David
Parker, Daniel J.
Forghany, Saeed
Nester, Christopher J.
Jiang, Liudi
author_sort Tang, Jinghua
collection PubMed
description Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial–lateral and anterior–posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.
format Online
Article
Text
id pubmed-10056665
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100566652023-03-30 A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes Tang, Jinghua Bader, Dan L. Moser, David Parker, Daniel J. Forghany, Saeed Nester, Christopher J. Jiang, Liudi Sensors (Basel) Article Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial–lateral and anterior–posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies. MDPI 2023-03-15 /pmc/articles/PMC10056665/ /pubmed/36991838 http://dx.doi.org/10.3390/s23063126 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tang, Jinghua
Bader, Dan L.
Moser, David
Parker, Daniel J.
Forghany, Saeed
Nester, Christopher J.
Jiang, Liudi
A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
title A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
title_full A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
title_fullStr A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
title_full_unstemmed A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
title_short A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
title_sort wearable insole system to measure plantar pressure and shear for people with diabetes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10056665/
https://www.ncbi.nlm.nih.gov/pubmed/36991838
http://dx.doi.org/10.3390/s23063126
work_keys_str_mv AT tangjinghua awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT baderdanl awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT moserdavid awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT parkerdanielj awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT forghanysaeed awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT nesterchristopherj awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT jiangliudi awearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT tangjinghua wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT baderdanl wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT moserdavid wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT parkerdanielj wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT forghanysaeed wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT nesterchristopherj wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes
AT jiangliudi wearableinsolesystemtomeasureplantarpressureandshearforpeoplewithdiabetes