Cargando…
Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies
The soft tissue-implant interface requires the formation of epithelium and connective tissue seal to hinder microbial infiltration and prevent epithelial down growth. Nanoporous titanium dioxide (TiO(2)) surface coatings have shown good potential for promoting soft tissue attachment to implant surfa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10056999/ https://www.ncbi.nlm.nih.gov/pubmed/36984413 http://dx.doi.org/10.3390/ma16062533 |
_version_ | 1785016257845657600 |
---|---|
author | Areid, Nagat Riivari, Sini Abushahba, Faleh Shahramian, Khalil Närhi, Timo |
author_facet | Areid, Nagat Riivari, Sini Abushahba, Faleh Shahramian, Khalil Närhi, Timo |
author_sort | Areid, Nagat |
collection | PubMed |
description | The soft tissue-implant interface requires the formation of epithelium and connective tissue seal to hinder microbial infiltration and prevent epithelial down growth. Nanoporous titanium dioxide (TiO(2)) surface coatings have shown good potential for promoting soft tissue attachment to implant surfaces. However, the impact of their surface properties on the biological response of gingival cells needs further investigation. This systematic review aimed to investigate the cellular behavior of gingival cells on TiO(2)-implant abutment coatings based on in vitro studies. The review was performed to answer the question: “How does the surface characteristic of TiO(2) coatings influence the gingival cell response in in vitro studies?”. A search in MEDLINE/PubMed and the web of science databases from 1990 to 2022 was performed using keywords. A quality assessment of the studies selected was performed using the SciRAP method. A total of 11 publications were selected from the 289 studies that fulfilled the inclusion criteria. The mean reporting and methodologic quality SciRAP scores were 82.7 ± 6.4/100 and 87 ± 4.2/100, respectively. Within the limitations of this in vitro systematic review, it can be concluded that the TiO(2) coatings with smooth nano-structured surface topography and good wettability improve gingival cell response compared to non-coated surfaces. |
format | Online Article Text |
id | pubmed-10056999 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100569992023-03-30 Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies Areid, Nagat Riivari, Sini Abushahba, Faleh Shahramian, Khalil Närhi, Timo Materials (Basel) Systematic Review The soft tissue-implant interface requires the formation of epithelium and connective tissue seal to hinder microbial infiltration and prevent epithelial down growth. Nanoporous titanium dioxide (TiO(2)) surface coatings have shown good potential for promoting soft tissue attachment to implant surfaces. However, the impact of their surface properties on the biological response of gingival cells needs further investigation. This systematic review aimed to investigate the cellular behavior of gingival cells on TiO(2)-implant abutment coatings based on in vitro studies. The review was performed to answer the question: “How does the surface characteristic of TiO(2) coatings influence the gingival cell response in in vitro studies?”. A search in MEDLINE/PubMed and the web of science databases from 1990 to 2022 was performed using keywords. A quality assessment of the studies selected was performed using the SciRAP method. A total of 11 publications were selected from the 289 studies that fulfilled the inclusion criteria. The mean reporting and methodologic quality SciRAP scores were 82.7 ± 6.4/100 and 87 ± 4.2/100, respectively. Within the limitations of this in vitro systematic review, it can be concluded that the TiO(2) coatings with smooth nano-structured surface topography and good wettability improve gingival cell response compared to non-coated surfaces. MDPI 2023-03-22 /pmc/articles/PMC10056999/ /pubmed/36984413 http://dx.doi.org/10.3390/ma16062533 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Systematic Review Areid, Nagat Riivari, Sini Abushahba, Faleh Shahramian, Khalil Närhi, Timo Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies |
title | Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies |
title_full | Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies |
title_fullStr | Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies |
title_full_unstemmed | Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies |
title_short | Influence of Surface Characteristics of TiO(2) Coatings on the Response of Gingival Cells: A Systematic Review of In Vitro Studies |
title_sort | influence of surface characteristics of tio(2) coatings on the response of gingival cells: a systematic review of in vitro studies |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10056999/ https://www.ncbi.nlm.nih.gov/pubmed/36984413 http://dx.doi.org/10.3390/ma16062533 |
work_keys_str_mv | AT areidnagat influenceofsurfacecharacteristicsoftio2coatingsontheresponseofgingivalcellsasystematicreviewofinvitrostudies AT riivarisini influenceofsurfacecharacteristicsoftio2coatingsontheresponseofgingivalcellsasystematicreviewofinvitrostudies AT abushahbafaleh influenceofsurfacecharacteristicsoftio2coatingsontheresponseofgingivalcellsasystematicreviewofinvitrostudies AT shahramiankhalil influenceofsurfacecharacteristicsoftio2coatingsontheresponseofgingivalcellsasystematicreviewofinvitrostudies AT narhitimo influenceofsurfacecharacteristicsoftio2coatingsontheresponseofgingivalcellsasystematicreviewofinvitrostudies |