Cargando…
Effect of Inhalation Profile on Delivery of Treprostinil Palmitil Inhalation Powder
Treprostinil palmitil (TP), a prodrug of treprostinil, is being developed as an inhalation powder (TPIP) for the treatment of patients with pulmonary arterial hypertension (PAH) and pulmonary hypertension due to interstitial lung disease (PH-ILD). In ongoing human clinical trials, TPIP is administer...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057251/ https://www.ncbi.nlm.nih.gov/pubmed/36986795 http://dx.doi.org/10.3390/pharmaceutics15030934 |
Sumario: | Treprostinil palmitil (TP), a prodrug of treprostinil, is being developed as an inhalation powder (TPIP) for the treatment of patients with pulmonary arterial hypertension (PAH) and pulmonary hypertension due to interstitial lung disease (PH-ILD). In ongoing human clinical trials, TPIP is administered via a commercially available high resistance (HR) RS01 capsule-based dry powder inhaler (DPI) device manufactured by Berry Global (formerly Plastiape), which utilizes the patient’s inspiratory flow to provide the required energy to deagglomerate and disperse the powder for delivery to their lungs. In this study, we characterized the aerosol performance of TPIP in response to changes in inhalation profiles to model more realistic use scenarios, i.e., for reduced inspiratory volumes and with inhalation acceleration rates that differ from those described in the compendia. The emitted dose of TP for all combinations of inhalation profiles and volumes ranged narrowly between 79 and 89% for the 16 and 32 mg TPIP capsules at the 60 LPM inspiratory flow rate but was reduced to 72–76% for the 16 mg TPIP capsule under the scenarios at the 30 LPM peak inspiratory flow rate. There were no meaningful differences in the fine particle dose (FPD) at all conditions at 60 LPM with the 4 L inhalation volume. The FPD values for the 16 mg TPIP capsule ranged narrowly between 60 and 65% of the loaded dose for all inhalation ramp rates with a 4 L volume and at both extremes of ramp rates for inhalation volumes down to 1 L, while the FPD values for the 32 mg TPIP capsule ranged between 53 and 65% of the loaded dose for all inhalation ramp rates with a 4 L volume and at both extremes of ramp rates for inhalation volumes down to 1 L for the 60 LPM flow rate. At the 30 LPM peak flow rate, the FPD values for the 16 mg TPIP capsule ranged narrowly between 54 and 58% of the loaded dose at both extremes of the ramp rates for inhalation volumes down to 1 L. Based on these in vitro findings, the TPIP delivery system appears not to be affected by the changes in inspiratory flow profiles or inspiratory volumes that might be expected to occur in patients with PAH or PH associated with underlying lung conditions such as ILD. |
---|