Cargando…

No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS

Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) is considered a standardized treatment of refractory ascites or variceal bleeding. TIPS thrombosis (TT) and/or portal vein thrombosis (PVT) are possible complications during/after TIPS placement. Previ...

Descripción completa

Detalles Bibliográficos
Autores principales: Bedreli, Sotiria, Manka, Paul, Buechter, Matthias, Jahn, Michael, Theysohn, Jens M., Canbay, Ali, Katsounas, Antonios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057309/
https://www.ncbi.nlm.nih.gov/pubmed/36983606
http://dx.doi.org/10.3390/jpm13030424
_version_ 1785016330892607488
author Bedreli, Sotiria
Manka, Paul
Buechter, Matthias
Jahn, Michael
Theysohn, Jens M.
Canbay, Ali
Katsounas, Antonios
author_facet Bedreli, Sotiria
Manka, Paul
Buechter, Matthias
Jahn, Michael
Theysohn, Jens M.
Canbay, Ali
Katsounas, Antonios
author_sort Bedreli, Sotiria
collection PubMed
description Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) is considered a standardized treatment of refractory ascites or variceal bleeding. TIPS thrombosis (TT) and/or portal vein thrombosis (PVT) are possible complications during/after TIPS placement. Previous studies suggested increased clotting activity in portal circulation (PORC). This pilot study aimed to evaluate alterations and differences of coagulation function in PORC and in peripheral circulation (PERC) via rotational thromboelastometry during TIPS. Methods: Blood samples were collected from cirrhotic patients (n = 13; median Model of End Stage Liver Disease, MELD Score: 12; median age: 60 years) undergoing TIPS (10/13 TIPSs were elective procedures due to refractory ascites) as follows: median cubital vein (MCV; PERC)—confluence of the three hepatic veins to the inferior cava vein (HV/ICV; PORC)—portal vein (PV; PORC)—TIPS (PORC). This research utilized four variables of the extrinsic test EXTEM, i.e., clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), and maximum lysis (ML). Results: EXTEM results [mean, M (range) ± standard deviation, SD (range)] showed no significant differences for CT [M (70–73) ± SD (9–13); p = 0.93] or CFT [M (137–155) ± SD (75–112); p = 0.97] or MCF [M (51–54) ± SD (9–10); p = 0.90] or ML [M (9–10) ± SD (4–5); p = 0.89] between the compartments, i.e., MCV vs. HV/ICV vs. PV vs. TIPS. Overall, we detected no differences in coagulation function between PERC and PORC. Conclusion: These results are in contrast to previous reports suggesting increased clotting activity in PORC vs. PERC in association with liver cirrhosis. Rotational thromboelastometry-based evaluation of coagulation function in PERC appears to reliably reflect coagulation function in PORC with respect to risk estimation for TT and/or PVT in cirrhotic patients undergoing TIPS.
format Online
Article
Text
id pubmed-10057309
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100573092023-03-30 No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS Bedreli, Sotiria Manka, Paul Buechter, Matthias Jahn, Michael Theysohn, Jens M. Canbay, Ali Katsounas, Antonios J Pers Med Article Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) is considered a standardized treatment of refractory ascites or variceal bleeding. TIPS thrombosis (TT) and/or portal vein thrombosis (PVT) are possible complications during/after TIPS placement. Previous studies suggested increased clotting activity in portal circulation (PORC). This pilot study aimed to evaluate alterations and differences of coagulation function in PORC and in peripheral circulation (PERC) via rotational thromboelastometry during TIPS. Methods: Blood samples were collected from cirrhotic patients (n = 13; median Model of End Stage Liver Disease, MELD Score: 12; median age: 60 years) undergoing TIPS (10/13 TIPSs were elective procedures due to refractory ascites) as follows: median cubital vein (MCV; PERC)—confluence of the three hepatic veins to the inferior cava vein (HV/ICV; PORC)—portal vein (PV; PORC)—TIPS (PORC). This research utilized four variables of the extrinsic test EXTEM, i.e., clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), and maximum lysis (ML). Results: EXTEM results [mean, M (range) ± standard deviation, SD (range)] showed no significant differences for CT [M (70–73) ± SD (9–13); p = 0.93] or CFT [M (137–155) ± SD (75–112); p = 0.97] or MCF [M (51–54) ± SD (9–10); p = 0.90] or ML [M (9–10) ± SD (4–5); p = 0.89] between the compartments, i.e., MCV vs. HV/ICV vs. PV vs. TIPS. Overall, we detected no differences in coagulation function between PERC and PORC. Conclusion: These results are in contrast to previous reports suggesting increased clotting activity in PORC vs. PERC in association with liver cirrhosis. Rotational thromboelastometry-based evaluation of coagulation function in PERC appears to reliably reflect coagulation function in PORC with respect to risk estimation for TT and/or PVT in cirrhotic patients undergoing TIPS. MDPI 2023-02-26 /pmc/articles/PMC10057309/ /pubmed/36983606 http://dx.doi.org/10.3390/jpm13030424 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bedreli, Sotiria
Manka, Paul
Buechter, Matthias
Jahn, Michael
Theysohn, Jens M.
Canbay, Ali
Katsounas, Antonios
No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS
title No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS
title_full No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS
title_fullStr No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS
title_full_unstemmed No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS
title_short No Differences in Rotational Thromboelastometry Measurements between Portal and Peripheral Circulation in Cirrhotic Patients Undergoing TIPS
title_sort no differences in rotational thromboelastometry measurements between portal and peripheral circulation in cirrhotic patients undergoing tips
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057309/
https://www.ncbi.nlm.nih.gov/pubmed/36983606
http://dx.doi.org/10.3390/jpm13030424
work_keys_str_mv AT bedrelisotiria nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips
AT mankapaul nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips
AT buechtermatthias nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips
AT jahnmichael nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips
AT theysohnjensm nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips
AT canbayali nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips
AT katsounasantonios nodifferencesinrotationalthromboelastometrymeasurementsbetweenportalandperipheralcirculationincirrhoticpatientsundergoingtips