Cargando…
Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions
This work is focused on the age-old challenge of developing optical sensors for acidity measurements in low-pH aqueous solutions (pH < 5). We prepared halochromic (3-aminopropyl)amino-substituted quinoxalines QC1 and QC8 possessing different hydrophilic–lipophilic balance (HLB) and investigated t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057592/ https://www.ncbi.nlm.nih.gov/pubmed/36991688 http://dx.doi.org/10.3390/s23062978 |
_version_ | 1785016407390420992 |
---|---|
author | Ermakova, Elizaveta V. Bol’shakova, Anastasia V. Bessmertnykh-Lemeune, Alla |
author_facet | Ermakova, Elizaveta V. Bol’shakova, Anastasia V. Bessmertnykh-Lemeune, Alla |
author_sort | Ermakova, Elizaveta V. |
collection | PubMed |
description | This work is focused on the age-old challenge of developing optical sensors for acidity measurements in low-pH aqueous solutions (pH < 5). We prepared halochromic (3-aminopropyl)amino-substituted quinoxalines QC1 and QC8 possessing different hydrophilic–lipophilic balance (HLB) and investigated them as molecular components of pH sensors. Embedding the hydrophilic quinoxaline QC1 into the agarose matrix by sol-gel process allows for fabrication of pH responsive polymers and paper test strips. The emissive films thus obtained can be used for a semi-quantitative dual-color visualization of pH in aqueous solution. Being exposed to acidic solutions with pH in the range of 1–5, they rapidly give different color changes when the analysis is performed in daylight or under irradiation at 365 nm. Compared with classical non-emissive pH indicators, these dual-responsive pH sensors allow for an increase in the accuracy of pH measurements, particularly in complex environmental samples. pH indicators for quantitative analysis can be prepared by the immobilization of amphiphilic quinoxaline QC8 using Langmuir–Blodgett (LB) and Langmuir–Schäfer (LS) techniques. Compound QC8 possessing two long alkyl chains (n-C(8)H(17)) forms stable Langmuir monolayers at the air–water interface, and these monolayers can be successfully transferred onto hydrophilic quartz and hydrophobic polyvinylchlorid (PVC) substrates using LB and LS techniques, respectively. The 30-layer films thus obtained are emissive, reveal excellent stability, and can be used as dual-responsive pH indicators for quantitative measurements in real-world samples with pH in the range of 1–3. The films can be regenerated by immersing them in basic aqueous solution (pH = 11) and can be reused at least five times. |
format | Online Article Text |
id | pubmed-10057592 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100575922023-03-30 Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions Ermakova, Elizaveta V. Bol’shakova, Anastasia V. Bessmertnykh-Lemeune, Alla Sensors (Basel) Article This work is focused on the age-old challenge of developing optical sensors for acidity measurements in low-pH aqueous solutions (pH < 5). We prepared halochromic (3-aminopropyl)amino-substituted quinoxalines QC1 and QC8 possessing different hydrophilic–lipophilic balance (HLB) and investigated them as molecular components of pH sensors. Embedding the hydrophilic quinoxaline QC1 into the agarose matrix by sol-gel process allows for fabrication of pH responsive polymers and paper test strips. The emissive films thus obtained can be used for a semi-quantitative dual-color visualization of pH in aqueous solution. Being exposed to acidic solutions with pH in the range of 1–5, they rapidly give different color changes when the analysis is performed in daylight or under irradiation at 365 nm. Compared with classical non-emissive pH indicators, these dual-responsive pH sensors allow for an increase in the accuracy of pH measurements, particularly in complex environmental samples. pH indicators for quantitative analysis can be prepared by the immobilization of amphiphilic quinoxaline QC8 using Langmuir–Blodgett (LB) and Langmuir–Schäfer (LS) techniques. Compound QC8 possessing two long alkyl chains (n-C(8)H(17)) forms stable Langmuir monolayers at the air–water interface, and these monolayers can be successfully transferred onto hydrophilic quartz and hydrophobic polyvinylchlorid (PVC) substrates using LB and LS techniques, respectively. The 30-layer films thus obtained are emissive, reveal excellent stability, and can be used as dual-responsive pH indicators for quantitative measurements in real-world samples with pH in the range of 1–3. The films can be regenerated by immersing them in basic aqueous solution (pH = 11) and can be reused at least five times. MDPI 2023-03-09 /pmc/articles/PMC10057592/ /pubmed/36991688 http://dx.doi.org/10.3390/s23062978 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ermakova, Elizaveta V. Bol’shakova, Anastasia V. Bessmertnykh-Lemeune, Alla Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions |
title | Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions |
title_full | Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions |
title_fullStr | Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions |
title_full_unstemmed | Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions |
title_short | Dual-Responsive and Reusable Optical Sensors Based on 2,3-Diaminoquinoxalines for Acidity Measurements in Low-pH Aqueous Solutions |
title_sort | dual-responsive and reusable optical sensors based on 2,3-diaminoquinoxalines for acidity measurements in low-ph aqueous solutions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057592/ https://www.ncbi.nlm.nih.gov/pubmed/36991688 http://dx.doi.org/10.3390/s23062978 |
work_keys_str_mv | AT ermakovaelizavetav dualresponsiveandreusableopticalsensorsbasedon23diaminoquinoxalinesforaciditymeasurementsinlowphaqueoussolutions AT bolshakovaanastasiav dualresponsiveandreusableopticalsensorsbasedon23diaminoquinoxalinesforaciditymeasurementsinlowphaqueoussolutions AT bessmertnykhlemeunealla dualresponsiveandreusableopticalsensorsbasedon23diaminoquinoxalinesforaciditymeasurementsinlowphaqueoussolutions |