Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study

The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-tape...

Descripción completa

Detalles Bibliográficos
Autores principales: Gehrke, Sergio Alexandre, Scarano, Antonio, Cortellari, Guillermo Castro, Fernandes, Gustavo Vicentis Oliveira, Mesquita, Alfredo Mikail Melo, Bianchini, Marco Aurélio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057670/
https://www.ncbi.nlm.nih.gov/pubmed/36976052
http://dx.doi.org/10.3390/jfb14030128
_version_ 1785016426474504192
author Gehrke, Sergio Alexandre
Scarano, Antonio
Cortellari, Guillermo Castro
Fernandes, Gustavo Vicentis Oliveira
Mesquita, Alfredo Mikail Melo
Bianchini, Marco Aurélio
author_facet Gehrke, Sergio Alexandre
Scarano, Antonio
Cortellari, Guillermo Castro
Fernandes, Gustavo Vicentis Oliveira
Mesquita, Alfredo Mikail Melo
Bianchini, Marco Aurélio
author_sort Gehrke, Sergio Alexandre
collection PubMed
description The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12–18 months, 34 between 19–24 months, and 44 between 25–33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was −0.67 ± 0.65 mm in mesial and −0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments’ diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, −0.57 ± 0.53 mm (mesial) and −0.66 ± 0.50 mm (distal), and −0.78 ± 0.75 mm (mesial) and −0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study.
format Online
Article
Text
id pubmed-10057670
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100576702023-03-30 Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study Gehrke, Sergio Alexandre Scarano, Antonio Cortellari, Guillermo Castro Fernandes, Gustavo Vicentis Oliveira Mesquita, Alfredo Mikail Melo Bianchini, Marco Aurélio J Funct Biomater Article The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12–18 months, 34 between 19–24 months, and 44 between 25–33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was −0.67 ± 0.65 mm in mesial and −0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments’ diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, −0.57 ± 0.53 mm (mesial) and −0.66 ± 0.50 mm (distal), and −0.78 ± 0.75 mm (mesial) and −0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study. MDPI 2023-02-26 /pmc/articles/PMC10057670/ /pubmed/36976052 http://dx.doi.org/10.3390/jfb14030128 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gehrke, Sergio Alexandre
Scarano, Antonio
Cortellari, Guillermo Castro
Fernandes, Gustavo Vicentis Oliveira
Mesquita, Alfredo Mikail Melo
Bianchini, Marco Aurélio
Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study
title Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study
title_full Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study
title_fullStr Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study
title_full_unstemmed Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study
title_short Marginal Bone Level and Biomechanical Behavior of Titanium-Indexed Abutment Base of Conical Connection Used for Single Ceramic Crowns on Morse-Taper Implant: A Clinical Retrospective Study
title_sort marginal bone level and biomechanical behavior of titanium-indexed abutment base of conical connection used for single ceramic crowns on morse-taper implant: a clinical retrospective study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057670/
https://www.ncbi.nlm.nih.gov/pubmed/36976052
http://dx.doi.org/10.3390/jfb14030128
work_keys_str_mv AT gehrkesergioalexandre marginalbonelevelandbiomechanicalbehavioroftitaniumindexedabutmentbaseofconicalconnectionusedforsingleceramiccrownsonmorsetaperimplantaclinicalretrospectivestudy
AT scaranoantonio marginalbonelevelandbiomechanicalbehavioroftitaniumindexedabutmentbaseofconicalconnectionusedforsingleceramiccrownsonmorsetaperimplantaclinicalretrospectivestudy
AT cortellariguillermocastro marginalbonelevelandbiomechanicalbehavioroftitaniumindexedabutmentbaseofconicalconnectionusedforsingleceramiccrownsonmorsetaperimplantaclinicalretrospectivestudy
AT fernandesgustavovicentisoliveira marginalbonelevelandbiomechanicalbehavioroftitaniumindexedabutmentbaseofconicalconnectionusedforsingleceramiccrownsonmorsetaperimplantaclinicalretrospectivestudy
AT mesquitaalfredomikailmelo marginalbonelevelandbiomechanicalbehavioroftitaniumindexedabutmentbaseofconicalconnectionusedforsingleceramiccrownsonmorsetaperimplantaclinicalretrospectivestudy
AT bianchinimarcoaurelio marginalbonelevelandbiomechanicalbehavioroftitaniumindexedabutmentbaseofconicalconnectionusedforsingleceramiccrownsonmorsetaperimplantaclinicalretrospectivestudy