Cargando…
Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices
To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endolumin...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057999/ https://www.ncbi.nlm.nih.gov/pubmed/36977294 http://dx.doi.org/10.3390/vision7010014 |
_version_ | 1785016510048108544 |
---|---|
author | Savastano, Alfonso Gambini, Gloria Savastano, Maria Cristina Carlà, Matteo Mario Rizzo, Clara Caporossi, Tomaso Crincoli, Emanuele Rizzo, Stanislao |
author_facet | Savastano, Alfonso Gambini, Gloria Savastano, Maria Cristina Carlà, Matteo Mario Rizzo, Clara Caporossi, Tomaso Crincoli, Emanuele Rizzo, Stanislao |
author_sort | Savastano, Alfonso |
collection | PubMed |
description | To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications. |
format | Online Article Text |
id | pubmed-10057999 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100579992023-03-30 Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices Savastano, Alfonso Gambini, Gloria Savastano, Maria Cristina Carlà, Matteo Mario Rizzo, Clara Caporossi, Tomaso Crincoli, Emanuele Rizzo, Stanislao Vision (Basel) Article To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications. MDPI 2023-02-24 /pmc/articles/PMC10057999/ /pubmed/36977294 http://dx.doi.org/10.3390/vision7010014 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Savastano, Alfonso Gambini, Gloria Savastano, Maria Cristina Carlà, Matteo Mario Rizzo, Clara Caporossi, Tomaso Crincoli, Emanuele Rizzo, Stanislao Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices |
title | Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices |
title_full | Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices |
title_fullStr | Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices |
title_full_unstemmed | Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices |
title_short | Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices |
title_sort | internal tube occlusion with an easily removable non-absorbable double suture: a novel surgical technique adjunct for non-valved glaucoma drainage devices |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10057999/ https://www.ncbi.nlm.nih.gov/pubmed/36977294 http://dx.doi.org/10.3390/vision7010014 |
work_keys_str_mv | AT savastanoalfonso internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT gambinigloria internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT savastanomariacristina internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT carlamatteomario internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT rizzoclara internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT caporossitomaso internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT crincoliemanuele internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices AT rizzostanislao internaltubeocclusionwithaneasilyremovablenonabsorbabledoublesutureanovelsurgicaltechniqueadjunctfornonvalvedglaucomadrainagedevices |