Cargando…

Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography

SIMPLE SUMMARY: The tooth is composed of three mineralized tissues: enamel, dentin, and cementum. Micro-computed tomography (mCT) is an imaging technology based on X-rays that allows non-invasive morphological and quantitative analysis. The present work aimed to determine the relative mineral densit...

Descripción completa

Detalles Bibliográficos
Autores principales: Silva, Graça, Babo, Pedro S., Azevedo, Jorge, Gomes, Manuela E., Viegas, Carlos, Requicha, João F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10058009/
https://www.ncbi.nlm.nih.gov/pubmed/36977256
http://dx.doi.org/10.3390/vetsci10030217
_version_ 1785016512395870208
author Silva, Graça
Babo, Pedro S.
Azevedo, Jorge
Gomes, Manuela E.
Viegas, Carlos
Requicha, João F.
author_facet Silva, Graça
Babo, Pedro S.
Azevedo, Jorge
Gomes, Manuela E.
Viegas, Carlos
Requicha, João F.
author_sort Silva, Graça
collection PubMed
description SIMPLE SUMMARY: The tooth is composed of three mineralized tissues: enamel, dentin, and cementum. Micro-computed tomography (mCT) is an imaging technology based on X-rays that allows non-invasive morphological and quantitative analysis. The present work aimed to determine the relative mineral density (MD) of the feline tooth using mCT. The studied sample consisted of nine canines extracted from European Shorthair cats due to medical indication. These teeth were evaluated through dental radiography and, using mCT, the values of MD of the root of each tooth and of specific segments corresponding to the coronal, middle, and apical thirds of the root were determined. Mean MD of root tissues was 1.374 ± 0040 g·cm(−3), and of hard root tissues 1.402 ± 0.035 g·cm(−3). The study of MD could become an ancillary method for the diagnosis and characterization of dental pathology. ABSTRACT: The tooth is made up of three mineralized tissues, enamel, dentin, and cementum, which surround a non-mineralized tissue called the dental pulp. Micro-computed tomography (mCT) is an imaging technology based on X-rays that allows non-invasive visualization of objects at a microscopic scale, according to their radiopacity and in three dimensions (3D). Likewise, it allows the subsequent execution of morphological and quantitative analysis of the objects, such as, for example, the determination of the relative mineral density (MD). The present work aimed to describe the MD of feline teeth using mCT. The studied sample consisted of four European Shorthair cats, from which nine canine teeth were extracted per medical indication. These teeth were evaluated through dental radiography before and after their extraction. Using mCT and the CTAn software, the values of the relative mineral density of the root of each tooth and of specific segments corresponding to the coronal, middle, and apical thirds of the root were determined. Mean MD of root tissues was 1.374 ± 0040 g·cm(−3), and of hard root, tissues was 1.402 ± 0.035 g·cm(−3). Through mCT, it was possible to determine the mean MD values of feline canine teeth. The study of MD could become an ancillary method for the diagnosis and characterization of dental pathology.
format Online
Article
Text
id pubmed-10058009
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100580092023-03-30 Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography Silva, Graça Babo, Pedro S. Azevedo, Jorge Gomes, Manuela E. Viegas, Carlos Requicha, João F. Vet Sci Article SIMPLE SUMMARY: The tooth is composed of three mineralized tissues: enamel, dentin, and cementum. Micro-computed tomography (mCT) is an imaging technology based on X-rays that allows non-invasive morphological and quantitative analysis. The present work aimed to determine the relative mineral density (MD) of the feline tooth using mCT. The studied sample consisted of nine canines extracted from European Shorthair cats due to medical indication. These teeth were evaluated through dental radiography and, using mCT, the values of MD of the root of each tooth and of specific segments corresponding to the coronal, middle, and apical thirds of the root were determined. Mean MD of root tissues was 1.374 ± 0040 g·cm(−3), and of hard root tissues 1.402 ± 0.035 g·cm(−3). The study of MD could become an ancillary method for the diagnosis and characterization of dental pathology. ABSTRACT: The tooth is made up of three mineralized tissues, enamel, dentin, and cementum, which surround a non-mineralized tissue called the dental pulp. Micro-computed tomography (mCT) is an imaging technology based on X-rays that allows non-invasive visualization of objects at a microscopic scale, according to their radiopacity and in three dimensions (3D). Likewise, it allows the subsequent execution of morphological and quantitative analysis of the objects, such as, for example, the determination of the relative mineral density (MD). The present work aimed to describe the MD of feline teeth using mCT. The studied sample consisted of four European Shorthair cats, from which nine canine teeth were extracted per medical indication. These teeth were evaluated through dental radiography before and after their extraction. Using mCT and the CTAn software, the values of the relative mineral density of the root of each tooth and of specific segments corresponding to the coronal, middle, and apical thirds of the root were determined. Mean MD of root tissues was 1.374 ± 0040 g·cm(−3), and of hard root, tissues was 1.402 ± 0.035 g·cm(−3). Through mCT, it was possible to determine the mean MD values of feline canine teeth. The study of MD could become an ancillary method for the diagnosis and characterization of dental pathology. MDPI 2023-03-12 /pmc/articles/PMC10058009/ /pubmed/36977256 http://dx.doi.org/10.3390/vetsci10030217 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Silva, Graça
Babo, Pedro S.
Azevedo, Jorge
Gomes, Manuela E.
Viegas, Carlos
Requicha, João F.
Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography
title Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography
title_full Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography
title_fullStr Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography
title_full_unstemmed Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography
title_short Evaluation of Feline Permanent Canine Tooth Mineral Density Using Micro-Computed Tomography
title_sort evaluation of feline permanent canine tooth mineral density using micro-computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10058009/
https://www.ncbi.nlm.nih.gov/pubmed/36977256
http://dx.doi.org/10.3390/vetsci10030217
work_keys_str_mv AT silvagraca evaluationoffelinepermanentcaninetoothmineraldensityusingmicrocomputedtomography
AT babopedros evaluationoffelinepermanentcaninetoothmineraldensityusingmicrocomputedtomography
AT azevedojorge evaluationoffelinepermanentcaninetoothmineraldensityusingmicrocomputedtomography
AT gomesmanuelae evaluationoffelinepermanentcaninetoothmineraldensityusingmicrocomputedtomography
AT viegascarlos evaluationoffelinepermanentcaninetoothmineraldensityusingmicrocomputedtomography
AT requichajoaof evaluationoffelinepermanentcaninetoothmineraldensityusingmicrocomputedtomography