Cargando…

SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials

(1) Background: The objective of this in vitro study is to evaluate the marginal accuracy of crowns created by CAD/CAM. (2) Methods: A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in a hemi-maxillary stone model and scanned. In total, 27 crowns...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferrini, Francesco, Paolone, Gaetano, Di Domenico, Giovanna Laura, Pagani, Nicolò, Gherlone, Enrico Felice
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10058296/
https://www.ncbi.nlm.nih.gov/pubmed/36984293
http://dx.doi.org/10.3390/ma16062413
_version_ 1785016592392781824
author Ferrini, Francesco
Paolone, Gaetano
Di Domenico, Giovanna Laura
Pagani, Nicolò
Gherlone, Enrico Felice
author_facet Ferrini, Francesco
Paolone, Gaetano
Di Domenico, Giovanna Laura
Pagani, Nicolò
Gherlone, Enrico Felice
author_sort Ferrini, Francesco
collection PubMed
description (1) Background: The objective of this in vitro study is to evaluate the marginal accuracy of crowns created by CAD/CAM. (2) Methods: A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in a hemi-maxillary stone model and scanned. In total, 27 crowns were fabricated, including 9 lithium disilicate crowns, 9 composite crowns, and 9 zirconia crowns. The measurements were determined by scanning electron microscopy. Descriptive analysis was performed using the mean and standard deviation, while the Kruskal–Wallis test was performed to determine whether the marginal discrepancies were significantly different between each group (p < 0.05). (3) Results: The lowest marginal gap value was reported for zirconia (21.45 ± 12.58 µm), followed by composite (44.7 ± 24.96 µm) and lithium disilicate (62.28 ± 51.8 µm). The Kruskal–Wallis tests revealed a statistically significant difference (p-value < 0.05) in the mean marginal gaps between different materials. (4) Conclusions: The proposed digital workflow can be a viable alternative for fixed prosthetic rehabilitations. The best performance in terms of marginal gap was achieved by zirconia crowns, but all three materials demonstrate marginal closure below the clinically accepted threshold value (120 µm). Clinical significance: although significant differences were reported, the investigated CAD/CAM materials showed clinically acceptable marginal gaps.
format Online
Article
Text
id pubmed-10058296
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100582962023-03-30 SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials Ferrini, Francesco Paolone, Gaetano Di Domenico, Giovanna Laura Pagani, Nicolò Gherlone, Enrico Felice Materials (Basel) Article (1) Background: The objective of this in vitro study is to evaluate the marginal accuracy of crowns created by CAD/CAM. (2) Methods: A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in a hemi-maxillary stone model and scanned. In total, 27 crowns were fabricated, including 9 lithium disilicate crowns, 9 composite crowns, and 9 zirconia crowns. The measurements were determined by scanning electron microscopy. Descriptive analysis was performed using the mean and standard deviation, while the Kruskal–Wallis test was performed to determine whether the marginal discrepancies were significantly different between each group (p < 0.05). (3) Results: The lowest marginal gap value was reported for zirconia (21.45 ± 12.58 µm), followed by composite (44.7 ± 24.96 µm) and lithium disilicate (62.28 ± 51.8 µm). The Kruskal–Wallis tests revealed a statistically significant difference (p-value < 0.05) in the mean marginal gaps between different materials. (4) Conclusions: The proposed digital workflow can be a viable alternative for fixed prosthetic rehabilitations. The best performance in terms of marginal gap was achieved by zirconia crowns, but all three materials demonstrate marginal closure below the clinically accepted threshold value (120 µm). Clinical significance: although significant differences were reported, the investigated CAD/CAM materials showed clinically acceptable marginal gaps. MDPI 2023-03-17 /pmc/articles/PMC10058296/ /pubmed/36984293 http://dx.doi.org/10.3390/ma16062413 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ferrini, Francesco
Paolone, Gaetano
Di Domenico, Giovanna Laura
Pagani, Nicolò
Gherlone, Enrico Felice
SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
title SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
title_full SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
title_fullStr SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
title_full_unstemmed SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
title_short SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
title_sort sem evaluation of the marginal accuracy of zirconia, lithium disilicate, and composite single crowns created by cad/cam method: comparative analysis of different materials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10058296/
https://www.ncbi.nlm.nih.gov/pubmed/36984293
http://dx.doi.org/10.3390/ma16062413
work_keys_str_mv AT ferrinifrancesco semevaluationofthemarginalaccuracyofzirconialithiumdisilicateandcompositesinglecrownscreatedbycadcammethodcomparativeanalysisofdifferentmaterials
AT paolonegaetano semevaluationofthemarginalaccuracyofzirconialithiumdisilicateandcompositesinglecrownscreatedbycadcammethodcomparativeanalysisofdifferentmaterials
AT didomenicogiovannalaura semevaluationofthemarginalaccuracyofzirconialithiumdisilicateandcompositesinglecrownscreatedbycadcammethodcomparativeanalysisofdifferentmaterials
AT paganinicolo semevaluationofthemarginalaccuracyofzirconialithiumdisilicateandcompositesinglecrownscreatedbycadcammethodcomparativeanalysisofdifferentmaterials
AT gherloneenricofelice semevaluationofthemarginalaccuracyofzirconialithiumdisilicateandcompositesinglecrownscreatedbycadcammethodcomparativeanalysisofdifferentmaterials