Cargando…
Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods
Lack of standardization of the retention phase has led to many studies of stability of movements and characteristic of retainers, disregarding the enamel repercussions of fixed retention on this phase. This study aimed to analyze different methods of enamel polishing after detachment of orthodontic...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10058876/ https://www.ncbi.nlm.nih.gov/pubmed/36984283 http://dx.doi.org/10.3390/ma16062403 |
_version_ | 1785016740317495296 |
---|---|
author | Iglesias, Angelica Flores, Teresa Moyano, Javier Artés, Montserrat Botella, Nuria Gil, Javier Puigdollers, Andreu |
author_facet | Iglesias, Angelica Flores, Teresa Moyano, Javier Artés, Montserrat Botella, Nuria Gil, Javier Puigdollers, Andreu |
author_sort | Iglesias, Angelica |
collection | PubMed |
description | Lack of standardization of the retention phase has led to many studies of stability of movements and characteristic of retainers, disregarding the enamel repercussions of fixed retention on this phase. This study aimed to analyze different methods of enamel polishing after detachment of orthodontic retainers. Forty-five healthy premolars were divided into three groups according to the polishing bur after debonding, and four specimens without intervention were used as control. A 0.038 × 0.015 inches gold chain was bonded between the premolars and then removed. The adhesive remnant was removed with three types of burs according to the study groups (Group 1: white stone at high speed; Group 2: high-speed handpiece with a 30-blade tungsten carbide bur; Group 3: low-speed handpiece and a 30-blade tungsten bur). After debonding and polishing, all samples were analyzed with a confocal microscopy on surface roughness parameters: Sa: Arithmetic mean of the height of the surface. Rq: Square mean of the height of the surface and Sz: Maximum surface height. Mechanical tests were carried out to determine the bonding stress of the retention adhered to the teeth using an electromechanical testing machine. The adhesion stress was 8.23 MPa (±0.87). The quality of the refinement of the enamel after debonding is essential in order to preserve its integrity. The use of the 30-blade tungsten carbide bur provides a smooth enamel surface after polishing. |
format | Online Article Text |
id | pubmed-10058876 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100588762023-03-30 Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods Iglesias, Angelica Flores, Teresa Moyano, Javier Artés, Montserrat Botella, Nuria Gil, Javier Puigdollers, Andreu Materials (Basel) Article Lack of standardization of the retention phase has led to many studies of stability of movements and characteristic of retainers, disregarding the enamel repercussions of fixed retention on this phase. This study aimed to analyze different methods of enamel polishing after detachment of orthodontic retainers. Forty-five healthy premolars were divided into three groups according to the polishing bur after debonding, and four specimens without intervention were used as control. A 0.038 × 0.015 inches gold chain was bonded between the premolars and then removed. The adhesive remnant was removed with three types of burs according to the study groups (Group 1: white stone at high speed; Group 2: high-speed handpiece with a 30-blade tungsten carbide bur; Group 3: low-speed handpiece and a 30-blade tungsten bur). After debonding and polishing, all samples were analyzed with a confocal microscopy on surface roughness parameters: Sa: Arithmetic mean of the height of the surface. Rq: Square mean of the height of the surface and Sz: Maximum surface height. Mechanical tests were carried out to determine the bonding stress of the retention adhered to the teeth using an electromechanical testing machine. The adhesion stress was 8.23 MPa (±0.87). The quality of the refinement of the enamel after debonding is essential in order to preserve its integrity. The use of the 30-blade tungsten carbide bur provides a smooth enamel surface after polishing. MDPI 2023-03-17 /pmc/articles/PMC10058876/ /pubmed/36984283 http://dx.doi.org/10.3390/ma16062403 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Iglesias, Angelica Flores, Teresa Moyano, Javier Artés, Montserrat Botella, Nuria Gil, Javier Puigdollers, Andreu Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods |
title | Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods |
title_full | Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods |
title_fullStr | Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods |
title_full_unstemmed | Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods |
title_short | Enamel Evaluation after Debonding of Fixed Retention and Polishing Treatment with Three Different Methods |
title_sort | enamel evaluation after debonding of fixed retention and polishing treatment with three different methods |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10058876/ https://www.ncbi.nlm.nih.gov/pubmed/36984283 http://dx.doi.org/10.3390/ma16062403 |
work_keys_str_mv | AT iglesiasangelica enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods AT floresteresa enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods AT moyanojavier enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods AT artesmontserrat enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods AT botellanuria enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods AT giljavier enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods AT puigdollersandreu enamelevaluationafterdebondingoffixedretentionandpolishingtreatmentwiththreedifferentmethods |