Cargando…
The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
AOTF calibration is a complex topic that has various aspects. As far as geometric calibration is concerned, it includes not only processing errors and fixing errors in the optical system, but also the error of geometric parameters of crystal (GPC). GPC is the preset input in the optical design and o...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10059917/ https://www.ncbi.nlm.nih.gov/pubmed/36984221 http://dx.doi.org/10.3390/ma16062341 |
_version_ | 1785016990022238208 |
---|---|
author | Yu, Kai Guo, Qi Zhao, Huijie Cheng, Chi |
author_facet | Yu, Kai Guo, Qi Zhao, Huijie Cheng, Chi |
author_sort | Yu, Kai |
collection | PubMed |
description | AOTF calibration is a complex topic that has various aspects. As far as geometric calibration is concerned, it includes not only processing errors and fixing errors in the optical system, but also the error of geometric parameters of crystal (GPC). GPC is the preset input in the optical design and optimization of Zemax, which determines the key parameters, including the spatial resolution, the field of view, and aberration. In particular, the compensation of aberration during the optical design requires accurate values of GPC. However, it is currently considered ideal. Therefore, two calibration methods based on the principle of parallel tangent are proposed: (1) the minimum-central wavelength method; (2) the minimum-frequency method. The deviation of the parallel tangent incident angle calibrated by the two methods is 0.03°. As a result, the tuning curve calculated in theory with the calibrated geometric parameters of AOTF is consistent with the tuning curve measured in practice. |
format | Online Article Text |
id | pubmed-10059917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-100599172023-03-30 The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design Yu, Kai Guo, Qi Zhao, Huijie Cheng, Chi Materials (Basel) Article AOTF calibration is a complex topic that has various aspects. As far as geometric calibration is concerned, it includes not only processing errors and fixing errors in the optical system, but also the error of geometric parameters of crystal (GPC). GPC is the preset input in the optical design and optimization of Zemax, which determines the key parameters, including the spatial resolution, the field of view, and aberration. In particular, the compensation of aberration during the optical design requires accurate values of GPC. However, it is currently considered ideal. Therefore, two calibration methods based on the principle of parallel tangent are proposed: (1) the minimum-central wavelength method; (2) the minimum-frequency method. The deviation of the parallel tangent incident angle calibrated by the two methods is 0.03°. As a result, the tuning curve calculated in theory with the calibrated geometric parameters of AOTF is consistent with the tuning curve measured in practice. MDPI 2023-03-14 /pmc/articles/PMC10059917/ /pubmed/36984221 http://dx.doi.org/10.3390/ma16062341 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yu, Kai Guo, Qi Zhao, Huijie Cheng, Chi The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design |
title | The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design |
title_full | The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design |
title_fullStr | The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design |
title_full_unstemmed | The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design |
title_short | The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design |
title_sort | calibration methods of geometric parameters of crystal for mid-infrared acousto-optic tunable filter-based imaging systems design |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10059917/ https://www.ncbi.nlm.nih.gov/pubmed/36984221 http://dx.doi.org/10.3390/ma16062341 |
work_keys_str_mv | AT yukai thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT guoqi thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT zhaohuijie thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT chengchi thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT yukai calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT guoqi calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT zhaohuijie calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign AT chengchi calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign |