Cargando…

The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design

AOTF calibration is a complex topic that has various aspects. As far as geometric calibration is concerned, it includes not only processing errors and fixing errors in the optical system, but also the error of geometric parameters of crystal (GPC). GPC is the preset input in the optical design and o...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Kai, Guo, Qi, Zhao, Huijie, Cheng, Chi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10059917/
https://www.ncbi.nlm.nih.gov/pubmed/36984221
http://dx.doi.org/10.3390/ma16062341
_version_ 1785016990022238208
author Yu, Kai
Guo, Qi
Zhao, Huijie
Cheng, Chi
author_facet Yu, Kai
Guo, Qi
Zhao, Huijie
Cheng, Chi
author_sort Yu, Kai
collection PubMed
description AOTF calibration is a complex topic that has various aspects. As far as geometric calibration is concerned, it includes not only processing errors and fixing errors in the optical system, but also the error of geometric parameters of crystal (GPC). GPC is the preset input in the optical design and optimization of Zemax, which determines the key parameters, including the spatial resolution, the field of view, and aberration. In particular, the compensation of aberration during the optical design requires accurate values of GPC. However, it is currently considered ideal. Therefore, two calibration methods based on the principle of parallel tangent are proposed: (1) the minimum-central wavelength method; (2) the minimum-frequency method. The deviation of the parallel tangent incident angle calibrated by the two methods is 0.03°. As a result, the tuning curve calculated in theory with the calibrated geometric parameters of AOTF is consistent with the tuning curve measured in practice.
format Online
Article
Text
id pubmed-10059917
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-100599172023-03-30 The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design Yu, Kai Guo, Qi Zhao, Huijie Cheng, Chi Materials (Basel) Article AOTF calibration is a complex topic that has various aspects. As far as geometric calibration is concerned, it includes not only processing errors and fixing errors in the optical system, but also the error of geometric parameters of crystal (GPC). GPC is the preset input in the optical design and optimization of Zemax, which determines the key parameters, including the spatial resolution, the field of view, and aberration. In particular, the compensation of aberration during the optical design requires accurate values of GPC. However, it is currently considered ideal. Therefore, two calibration methods based on the principle of parallel tangent are proposed: (1) the minimum-central wavelength method; (2) the minimum-frequency method. The deviation of the parallel tangent incident angle calibrated by the two methods is 0.03°. As a result, the tuning curve calculated in theory with the calibrated geometric parameters of AOTF is consistent with the tuning curve measured in practice. MDPI 2023-03-14 /pmc/articles/PMC10059917/ /pubmed/36984221 http://dx.doi.org/10.3390/ma16062341 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yu, Kai
Guo, Qi
Zhao, Huijie
Cheng, Chi
The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
title The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
title_full The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
title_fullStr The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
title_full_unstemmed The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
title_short The Calibration Methods of Geometric Parameters of Crystal for Mid-Infrared Acousto-Optic Tunable Filter-Based Imaging Systems Design
title_sort calibration methods of geometric parameters of crystal for mid-infrared acousto-optic tunable filter-based imaging systems design
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10059917/
https://www.ncbi.nlm.nih.gov/pubmed/36984221
http://dx.doi.org/10.3390/ma16062341
work_keys_str_mv AT yukai thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT guoqi thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT zhaohuijie thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT chengchi thecalibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT yukai calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT guoqi calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT zhaohuijie calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign
AT chengchi calibrationmethodsofgeometricparametersofcrystalformidinfraredacoustooptictunablefilterbasedimagingsystemsdesign