Cargando…
Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study
INTRODUCTION: Emergency neonatal resuscitation equipment is often organized into “code carts”. Simulation studies previously examined human factors of neonatal code carts and equipment; however, visual attention analysis with eye-tracking might further inform equipment design. OBJECTIVES: To evaluat...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10060515/ https://www.ncbi.nlm.nih.gov/pubmed/37009282 http://dx.doi.org/10.3389/fped.2023.1116893 |
_version_ | 1785017107243597824 |
---|---|
author | Chen, Linda Gai Rui Law, Brenda Hiu Yan |
author_facet | Chen, Linda Gai Rui Law, Brenda Hiu Yan |
author_sort | Chen, Linda Gai Rui |
collection | PubMed |
description | INTRODUCTION: Emergency neonatal resuscitation equipment is often organized into “code carts”. Simulation studies previously examined human factors of neonatal code carts and equipment; however, visual attention analysis with eye-tracking might further inform equipment design. OBJECTIVES: To evaluate human factors of neonatal resuscitation equipment by: (1) comparing epinephrine preparation speed from adult pre-filled syringe vs. medication vial, (2) comparing equipment retrieval times from two carts and (3) utilizing eye-tracking to study visual attention and user experience. METHODS: We conducted a 2-site randomized cross-over simulation study. Site 1 is a perinatal NICU with carts focused on airway management. Site 2 is a surgical NICU with carts improved with compartments and task-based kits. Participants were fitted with eye-tracking glasses then randomized to prepare two epinephrine doses using two methods, starting with an adult epinephrine prefilled syringe or a multiple access vial. Participants then obtained items for 7 tasks from their local cart. Post-simulation, participants completed surveys and semi-structured interviews while viewing eye-tracked video of their performance. Epinephrine preparation times were compared between the two methods. Equipment retrieval times and survey responses were compared between sites. Eye-tracking was analyzed for areas of interest (AOIs) and gaze shifts between AOIs. Interviews were subject to thematic analysis. RESULTS: Forty HCPs participated (20/site). It was faster to draw the first epinephrine dose using the medication vial (29.9s vs. 47.6s, p < 0.001). Time to draw the second dose was similar (21.2s vs. 19s, p = 0.563). It was faster to obtain equipment from the Perinatal cart (164.4s v 228.9s, p < 0.027). Participants at both sites found their carts easy to use. Participants looked at many AOIs (54 for Perinatal vs. 76 for Surgical carts, p < 0.001) with 1 gaze shifts/second for both. Themes for epinephrine preparation include: Facilitators and Threats to Performance, and Discrepancies due to Stimulation Conditions. Themes for code carts include: Facilitators and Threats to Performance, Orienting with Prescan, and Suggestions for Improvement. Suggested cart improvements include: adding prompts, task-based grouping, and positioning small equipment more visibly. Task-based kits were welcomed, but more orientation is needed. CONCLUSIONS: Eye-tracked simulations provided human factors assessment of emergency neonatal code carts and epinephrine preparation. |
format | Online Article Text |
id | pubmed-10060515 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-100605152023-03-31 Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study Chen, Linda Gai Rui Law, Brenda Hiu Yan Front Pediatr Pediatrics INTRODUCTION: Emergency neonatal resuscitation equipment is often organized into “code carts”. Simulation studies previously examined human factors of neonatal code carts and equipment; however, visual attention analysis with eye-tracking might further inform equipment design. OBJECTIVES: To evaluate human factors of neonatal resuscitation equipment by: (1) comparing epinephrine preparation speed from adult pre-filled syringe vs. medication vial, (2) comparing equipment retrieval times from two carts and (3) utilizing eye-tracking to study visual attention and user experience. METHODS: We conducted a 2-site randomized cross-over simulation study. Site 1 is a perinatal NICU with carts focused on airway management. Site 2 is a surgical NICU with carts improved with compartments and task-based kits. Participants were fitted with eye-tracking glasses then randomized to prepare two epinephrine doses using two methods, starting with an adult epinephrine prefilled syringe or a multiple access vial. Participants then obtained items for 7 tasks from their local cart. Post-simulation, participants completed surveys and semi-structured interviews while viewing eye-tracked video of their performance. Epinephrine preparation times were compared between the two methods. Equipment retrieval times and survey responses were compared between sites. Eye-tracking was analyzed for areas of interest (AOIs) and gaze shifts between AOIs. Interviews were subject to thematic analysis. RESULTS: Forty HCPs participated (20/site). It was faster to draw the first epinephrine dose using the medication vial (29.9s vs. 47.6s, p < 0.001). Time to draw the second dose was similar (21.2s vs. 19s, p = 0.563). It was faster to obtain equipment from the Perinatal cart (164.4s v 228.9s, p < 0.027). Participants at both sites found their carts easy to use. Participants looked at many AOIs (54 for Perinatal vs. 76 for Surgical carts, p < 0.001) with 1 gaze shifts/second for both. Themes for epinephrine preparation include: Facilitators and Threats to Performance, and Discrepancies due to Stimulation Conditions. Themes for code carts include: Facilitators and Threats to Performance, Orienting with Prescan, and Suggestions for Improvement. Suggested cart improvements include: adding prompts, task-based grouping, and positioning small equipment more visibly. Task-based kits were welcomed, but more orientation is needed. CONCLUSIONS: Eye-tracked simulations provided human factors assessment of emergency neonatal code carts and epinephrine preparation. Frontiers Media S.A. 2023-03-16 /pmc/articles/PMC10060515/ /pubmed/37009282 http://dx.doi.org/10.3389/fped.2023.1116893 Text en © 2023 Chen and Law. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Pediatrics Chen, Linda Gai Rui Law, Brenda Hiu Yan Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study |
title | Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study |
title_full | Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study |
title_fullStr | Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study |
title_full_unstemmed | Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study |
title_short | Use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: A simulation study |
title_sort | use of eye-tracking to evaluate human factors in accessing neonatal resuscitation equipment and medications for advanced resuscitation: a simulation study |
topic | Pediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10060515/ https://www.ncbi.nlm.nih.gov/pubmed/37009282 http://dx.doi.org/10.3389/fped.2023.1116893 |
work_keys_str_mv | AT chenlindagairui useofeyetrackingtoevaluatehumanfactorsinaccessingneonatalresuscitationequipmentandmedicationsforadvancedresuscitationasimulationstudy AT lawbrendahiuyan useofeyetrackingtoevaluatehumanfactorsinaccessingneonatalresuscitationequipmentandmedicationsforadvancedresuscitationasimulationstudy |