PURPOSE: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This va...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10060752/ https://www.ncbi.nlm.nih.gov/pubmed/37006789 http://dx.doi.org/10.5624/isd.20220131 |
_version_ | 1785017143795908608 |
---|---|
author | Deferm, Julie Tilly Baan, Frank Nijsink, Johan Verhamme, Luc Maal, Thomas Meijer, Gert |
author_facet | Deferm, Julie Tilly Baan, Frank Nijsink, Johan Verhamme, Luc Maal, Thomas Meijer, Gert |
author_sort | Deferm, Julie Tilly |
collection | PubMed |
description | PURPOSE: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. MATERIALS AND METHODS: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient (ICC) was calculated to evaluate the reproducibility of the registration method. RESULTS: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10 ± 0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent (ICC=0.94; 95% confidence interval, 0.81–0.98). CONCLUSION: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision. |
format | Online Article Text |
id | pubmed-10060752 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-100607522023-03-31 Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan Deferm, Julie Tilly Baan, Frank Nijsink, Johan Verhamme, Luc Maal, Thomas Meijer, Gert Imaging Sci Dent Original Article PURPOSE: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. MATERIALS AND METHODS: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient (ICC) was calculated to evaluate the reproducibility of the registration method. RESULTS: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10 ± 0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent (ICC=0.94; 95% confidence interval, 0.81–0.98). CONCLUSION: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision. Korean Academy of Oral and Maxillofacial Radiology 2023-03 2023-02-01 /pmc/articles/PMC10060752/ /pubmed/37006789 http://dx.doi.org/10.5624/isd.20220131 Text en Copyright © 2023 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0 (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Deferm, Julie Tilly Baan, Frank Nijsink, Johan Verhamme, Luc Maal, Thomas Meijer, Gert Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
title | Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
title_full | Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
title_fullStr | Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
title_full_unstemmed | Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
title_short | Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
title_sort | intraoral scanning of the edentulous jaw without additional markers: an in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10060752/ https://www.ncbi.nlm.nih.gov/pubmed/37006789 http://dx.doi.org/10.5624/isd.20220131 |
work_keys_str_mv | AT defermjulietilly intraoralscanningoftheedentulousjawwithoutadditionalmarkersaninvivovalidationstudyonscanningprecisionandregistrationofanintraoralscanwithaconebeamcomputedtomographyscan AT baanfrank intraoralscanningoftheedentulousjawwithoutadditionalmarkersaninvivovalidationstudyonscanningprecisionandregistrationofanintraoralscanwithaconebeamcomputedtomographyscan AT nijsinkjohan intraoralscanningoftheedentulousjawwithoutadditionalmarkersaninvivovalidationstudyonscanningprecisionandregistrationofanintraoralscanwithaconebeamcomputedtomographyscan AT verhammeluc intraoralscanningoftheedentulousjawwithoutadditionalmarkersaninvivovalidationstudyonscanningprecisionandregistrationofanintraoralscanwithaconebeamcomputedtomographyscan AT maalthomas intraoralscanningoftheedentulousjawwithoutadditionalmarkersaninvivovalidationstudyonscanningprecisionandregistrationofanintraoralscanwithaconebeamcomputedtomographyscan AT meijergert intraoralscanningoftheedentulousjawwithoutadditionalmarkersaninvivovalidationstudyonscanningprecisionandregistrationofanintraoralscanwithaconebeamcomputedtomographyscan |