Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator

BACKGROUND: The management of the oxygenator can be prolonged in the long-term procedures especially during extracorporeal membrane oxygenation (ECMO) for bridge to transplant or bridge to recovery. Long-term use often involves an overrun of the time of use with respect to certification of the oxyge...

Descripción completa

Detalles Bibliográficos
Autores principales: Condello, Ignazio, Lorusso, Roberto, Nasso, Giuseppe, Speziale, Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10061787/
https://www.ncbi.nlm.nih.gov/pubmed/36998079
http://dx.doi.org/10.1186/s13019-023-02190-9
_version_ 1785017363514523648
author Condello, Ignazio
Lorusso, Roberto
Nasso, Giuseppe
Speziale, Giuseppe
author_facet Condello, Ignazio
Lorusso, Roberto
Nasso, Giuseppe
Speziale, Giuseppe
author_sort Condello, Ignazio
collection PubMed
description BACKGROUND: The management of the oxygenator can be prolonged in the long-term procedures especially during extracorporeal membrane oxygenation (ECMO) for bridge to transplant or bridge to recovery. Long-term use often involves an overrun of the time of use with respect to certification of the oxygenating module of 14 days, for the maintenance of performance and efficiency of the oxygenator. The evaluation of the long-term oxygenator efficiency is complex and depends on the: patient pathology, ECMO configuration, the management of coagulation and anticoagulation, materials selection and circuit components, the structure, design and performance of the oxygenator. In this context we investgated the long-term performance of the A.L.ONE Eurosets ECMO oxygenator in relation to the parameters prodromal to replacement. METHODS: We retrospectively collected eight years data from Anthea Hospital GVM Care & Research, Bari, Italy on the long-term use exceeding 14 days of Eurosets A.L.ONE ECMO Adult oxygenator in Polymetylpentene fiber, for ECMO procedures, including the procedures: Veno Arterial (VA) ECMO post-cardiotomy or not, veno-venous (VV) ECMO. The primary end points were the evaluation of Gas Transfer: oxygen partial pressure (PO(2)) post oxygenator, Carbon dioxide partial pressure (PCO(2)) post oxygenator, the oxygen transfer across the oxygenator membrane V′O(2), differential CO(2) content across oxygenator; Pressure monitoring: oxygenator pressure Drop in relation to Blood flow rate (BFR) (ΔP); Hematologic values: Hemoglobin, Fibrinogen, Platelets, aPTT, D-Dimer, LDH. RESULTS: Nine VA ECMO patients who used the oxygenator for 18.5 days and two VV ECMO patients who used the oxygenators for 17.2 days on the seventeenth days reported average values PaO(2) (267 ± 29 mmHg); PaCO(2) (34 ± 4 mmHg) with gas blender values set to 3.8 ± 0.6 L/min of air and a FiO(2) of 78 ± 5%; the transfer across the oxygenator membrane V′O(2) was 189 ± 43 (ml/min/m(2)). The mean peak of partial pressure of carbon dioxide from the gas exhaust of oxygenator (P(E)CO(2)) was 38 ± 4 mmHg; differential CO(2) across the oxygenator “pre-oxygenator PCO(2)–post-oxygenator PCO(2)” (18 ± 6 mmHg); the mean blood flow rate (BFR) 4.5 ± 0.6 (L/minute); the pump revolution per minutes mean maximum rate was 4254 ± 345 (RPM); the mean pressure drop (ΔP) was 76 ± 12 mmHg; the mean peak of d-dimers (DDs) was 23.6 ± 0.8 mg / dL; the mean peak of LDH was 230 ± 55 (mg/dl); fibrinogen mean peak 223 ± 40 (mg/dl). CONCLUSIONS: The performance of the Eurosets A.L.ONE ECMO Adult polymethylpentene fiber oxygenator in our experience has proven efficiency in terms of O(2) uptake and CO(2) removal, blood fluid dynamics, metabolic compensation and heat exchange in the long-term treatment. The device was safe without iatrogenic problems over a period of 14 days in the patients undergoing ECMO VA and in all patients undergoing VV ECMO with continuous administration of anticoagulation therapy.
format Online
Article
Text
id pubmed-10061787
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-100617872023-03-31 Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator Condello, Ignazio Lorusso, Roberto Nasso, Giuseppe Speziale, Giuseppe J Cardiothorac Surg Research BACKGROUND: The management of the oxygenator can be prolonged in the long-term procedures especially during extracorporeal membrane oxygenation (ECMO) for bridge to transplant or bridge to recovery. Long-term use often involves an overrun of the time of use with respect to certification of the oxygenating module of 14 days, for the maintenance of performance and efficiency of the oxygenator. The evaluation of the long-term oxygenator efficiency is complex and depends on the: patient pathology, ECMO configuration, the management of coagulation and anticoagulation, materials selection and circuit components, the structure, design and performance of the oxygenator. In this context we investgated the long-term performance of the A.L.ONE Eurosets ECMO oxygenator in relation to the parameters prodromal to replacement. METHODS: We retrospectively collected eight years data from Anthea Hospital GVM Care & Research, Bari, Italy on the long-term use exceeding 14 days of Eurosets A.L.ONE ECMO Adult oxygenator in Polymetylpentene fiber, for ECMO procedures, including the procedures: Veno Arterial (VA) ECMO post-cardiotomy or not, veno-venous (VV) ECMO. The primary end points were the evaluation of Gas Transfer: oxygen partial pressure (PO(2)) post oxygenator, Carbon dioxide partial pressure (PCO(2)) post oxygenator, the oxygen transfer across the oxygenator membrane V′O(2), differential CO(2) content across oxygenator; Pressure monitoring: oxygenator pressure Drop in relation to Blood flow rate (BFR) (ΔP); Hematologic values: Hemoglobin, Fibrinogen, Platelets, aPTT, D-Dimer, LDH. RESULTS: Nine VA ECMO patients who used the oxygenator for 18.5 days and two VV ECMO patients who used the oxygenators for 17.2 days on the seventeenth days reported average values PaO(2) (267 ± 29 mmHg); PaCO(2) (34 ± 4 mmHg) with gas blender values set to 3.8 ± 0.6 L/min of air and a FiO(2) of 78 ± 5%; the transfer across the oxygenator membrane V′O(2) was 189 ± 43 (ml/min/m(2)). The mean peak of partial pressure of carbon dioxide from the gas exhaust of oxygenator (P(E)CO(2)) was 38 ± 4 mmHg; differential CO(2) across the oxygenator “pre-oxygenator PCO(2)–post-oxygenator PCO(2)” (18 ± 6 mmHg); the mean blood flow rate (BFR) 4.5 ± 0.6 (L/minute); the pump revolution per minutes mean maximum rate was 4254 ± 345 (RPM); the mean pressure drop (ΔP) was 76 ± 12 mmHg; the mean peak of d-dimers (DDs) was 23.6 ± 0.8 mg / dL; the mean peak of LDH was 230 ± 55 (mg/dl); fibrinogen mean peak 223 ± 40 (mg/dl). CONCLUSIONS: The performance of the Eurosets A.L.ONE ECMO Adult polymethylpentene fiber oxygenator in our experience has proven efficiency in terms of O(2) uptake and CO(2) removal, blood fluid dynamics, metabolic compensation and heat exchange in the long-term treatment. The device was safe without iatrogenic problems over a period of 14 days in the patients undergoing ECMO VA and in all patients undergoing VV ECMO with continuous administration of anticoagulation therapy. BioMed Central 2023-03-30 /pmc/articles/PMC10061787/ /pubmed/36998079 http://dx.doi.org/10.1186/s13019-023-02190-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Condello, Ignazio
Lorusso, Roberto
Nasso, Giuseppe
Speziale, Giuseppe
Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator
title Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator
title_full Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator
title_fullStr Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator
title_full_unstemmed Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator
title_short Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator
title_sort long-term ecmo, efficiency and performance of eurosets adult a.l.one ecmo oxygenator
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10061787/
https://www.ncbi.nlm.nih.gov/pubmed/36998079
http://dx.doi.org/10.1186/s13019-023-02190-9
work_keys_str_mv AT condelloignazio longtermecmoefficiencyandperformanceofeurosetsadultaloneecmooxygenator
AT lorussoroberto longtermecmoefficiencyandperformanceofeurosetsadultaloneecmooxygenator
AT nassogiuseppe longtermecmoefficiencyandperformanceofeurosetsadultaloneecmooxygenator
AT spezialegiuseppe longtermecmoefficiencyandperformanceofeurosetsadultaloneecmooxygenator