Cargando…
Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre
AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062326/ https://www.ncbi.nlm.nih.gov/pubmed/36660771 http://dx.doi.org/10.1093/europace/euac272 |
_version_ | 1785017470144217088 |
---|---|
author | Ząbek, Andrzej Boczar, Krzysztof Ulman, Mateusz Holcman, Katarzyna Kostkiewicz, Magdalena Pfitzner, Roman Dębski, Maciej Musiał, Robert Lelakowski, Jacek Małecka, Barbara |
author_facet | Ząbek, Andrzej Boczar, Krzysztof Ulman, Mateusz Holcman, Katarzyna Kostkiewicz, Magdalena Pfitzner, Roman Dębski, Maciej Musiał, Robert Lelakowski, Jacek Małecka, Barbara |
author_sort | Ząbek, Andrzej |
collection | PubMed |
description | AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs. |
format | Online Article Text |
id | pubmed-10062326 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-100623262023-03-31 Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre Ząbek, Andrzej Boczar, Krzysztof Ulman, Mateusz Holcman, Katarzyna Kostkiewicz, Magdalena Pfitzner, Roman Dębski, Maciej Musiał, Robert Lelakowski, Jacek Małecka, Barbara Europace Clinical Research AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs. Oxford University Press 2023-01-20 /pmc/articles/PMC10062326/ /pubmed/36660771 http://dx.doi.org/10.1093/europace/euac272 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Clinical Research Ząbek, Andrzej Boczar, Krzysztof Ulman, Mateusz Holcman, Katarzyna Kostkiewicz, Magdalena Pfitzner, Roman Dębski, Maciej Musiał, Robert Lelakowski, Jacek Małecka, Barbara Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
title | Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
title_full | Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
title_fullStr | Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
title_full_unstemmed | Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
title_short | Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
title_sort | mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062326/ https://www.ncbi.nlm.nih.gov/pubmed/36660771 http://dx.doi.org/10.1093/europace/euac272 |
work_keys_str_mv | AT zabekandrzej mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT boczarkrzysztof mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT ulmanmateusz mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT holcmankatarzyna mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT kostkiewiczmagdalena mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT pfitznerroman mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT debskimaciej mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT musiałrobert mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT lelakowskijacek mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre AT małeckabarbara mechanicalextractionofimplantablecardioverterdefibrillatorleadswithadwelltimeofmorethan10yearsinsightsfromasinglehighvolumecentre |