Cargando…

Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test

AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocard...

Descripción completa

Detalles Bibliográficos
Autores principales: De Lucia, Raffaele, Giannini, Cristina, Parollo, Matteo, Barletta, Valentina, Costa, Giulia, Giannotti Santoro, Mario, Primerano, Chiara, Angelillis, Marco, De Carlo, Marco, Zucchelli, Giulio, Bongiorni, Maria Grazia, Petronio, Anna Sonia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062351/
https://www.ncbi.nlm.nih.gov/pubmed/36691737
http://dx.doi.org/10.1093/europace/euac285
_version_ 1785017475898802176
author De Lucia, Raffaele
Giannini, Cristina
Parollo, Matteo
Barletta, Valentina
Costa, Giulia
Giannotti Santoro, Mario
Primerano, Chiara
Angelillis, Marco
De Carlo, Marco
Zucchelli, Giulio
Bongiorni, Maria Grazia
Petronio, Anna Sonia
author_facet De Lucia, Raffaele
Giannini, Cristina
Parollo, Matteo
Barletta, Valentina
Costa, Giulia
Giannotti Santoro, Mario
Primerano, Chiara
Angelillis, Marco
De Carlo, Marco
Zucchelli, Giulio
Bongiorni, Maria Grazia
Petronio, Anna Sonia
author_sort De Lucia, Raffaele
collection PubMed
description AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance.
format Online
Article
Text
id pubmed-10062351
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-100623512023-03-31 Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test De Lucia, Raffaele Giannini, Cristina Parollo, Matteo Barletta, Valentina Costa, Giulia Giannotti Santoro, Mario Primerano, Chiara Angelillis, Marco De Carlo, Marco Zucchelli, Giulio Bongiorni, Maria Grazia Petronio, Anna Sonia Europace Clinical Research AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance. Oxford University Press 2023-01-24 /pmc/articles/PMC10062351/ /pubmed/36691737 http://dx.doi.org/10.1093/europace/euac285 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Clinical Research
De Lucia, Raffaele
Giannini, Cristina
Parollo, Matteo
Barletta, Valentina
Costa, Giulia
Giannotti Santoro, Mario
Primerano, Chiara
Angelillis, Marco
De Carlo, Marco
Zucchelli, Giulio
Bongiorni, Maria Grazia
Petronio, Anna Sonia
Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
title Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
title_full Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
title_fullStr Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
title_full_unstemmed Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
title_short Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
title_sort non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062351/
https://www.ncbi.nlm.nih.gov/pubmed/36691737
http://dx.doi.org/10.1093/europace/euac285
work_keys_str_mv AT deluciaraffaele noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT gianninicristina noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT parollomatteo noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT barlettavalentina noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT costagiulia noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT giannottisantoromario noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT primeranochiara noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT angelillismarco noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT decarlomarco noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT zucchelligiulio noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT bongiornimariagrazia noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest
AT petronioannasonia noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest