Cargando…
Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test
AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocard...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062351/ https://www.ncbi.nlm.nih.gov/pubmed/36691737 http://dx.doi.org/10.1093/europace/euac285 |
_version_ | 1785017475898802176 |
---|---|
author | De Lucia, Raffaele Giannini, Cristina Parollo, Matteo Barletta, Valentina Costa, Giulia Giannotti Santoro, Mario Primerano, Chiara Angelillis, Marco De Carlo, Marco Zucchelli, Giulio Bongiorni, Maria Grazia Petronio, Anna Sonia |
author_facet | De Lucia, Raffaele Giannini, Cristina Parollo, Matteo Barletta, Valentina Costa, Giulia Giannotti Santoro, Mario Primerano, Chiara Angelillis, Marco De Carlo, Marco Zucchelli, Giulio Bongiorni, Maria Grazia Petronio, Anna Sonia |
author_sort | De Lucia, Raffaele |
collection | PubMed |
description | AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance. |
format | Online Article Text |
id | pubmed-10062351 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-100623512023-03-31 Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test De Lucia, Raffaele Giannini, Cristina Parollo, Matteo Barletta, Valentina Costa, Giulia Giannotti Santoro, Mario Primerano, Chiara Angelillis, Marco De Carlo, Marco Zucchelli, Giulio Bongiorni, Maria Grazia Petronio, Anna Sonia Europace Clinical Research AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance. Oxford University Press 2023-01-24 /pmc/articles/PMC10062351/ /pubmed/36691737 http://dx.doi.org/10.1093/europace/euac285 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Clinical Research De Lucia, Raffaele Giannini, Cristina Parollo, Matteo Barletta, Valentina Costa, Giulia Giannotti Santoro, Mario Primerano, Chiara Angelillis, Marco De Carlo, Marco Zucchelli, Giulio Bongiorni, Maria Grazia Petronio, Anna Sonia Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
title | Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
title_full | Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
title_fullStr | Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
title_full_unstemmed | Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
title_short | Non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
title_sort | non-continuous mobile electrocardiogram monitoring for post-transcatheter aortic valve replacement delayed conduction disorders put to the test |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062351/ https://www.ncbi.nlm.nih.gov/pubmed/36691737 http://dx.doi.org/10.1093/europace/euac285 |
work_keys_str_mv | AT deluciaraffaele noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT gianninicristina noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT parollomatteo noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT barlettavalentina noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT costagiulia noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT giannottisantoromario noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT primeranochiara noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT angelillismarco noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT decarlomarco noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT zucchelligiulio noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT bongiornimariagrazia noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest AT petronioannasonia noncontinuousmobileelectrocardiogrammonitoringforposttranscatheteraorticvalvereplacementdelayedconductiondisordersputtothetest |