Cargando…

Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study

AIMS: The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the ‘close protocol’ has been verified. Since lesion...

Descripción completa

Detalles Bibliográficos
Autores principales: Heeger, Christian-H, Sano, Makoto, Popescu, Sorin Ștefan, Subin, Behnam, Feher, Marcel, Phan, Huong-Lan, Kirstein, Bettina, Vogler, Julia, Eitel, Charlotte, Hatahet, Sascha, Kuck, Karl-Heinz, Tilz, Roland R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062369/
https://www.ncbi.nlm.nih.gov/pubmed/36546582
http://dx.doi.org/10.1093/europace/euac243
_version_ 1785017480222081024
author Heeger, Christian-H
Sano, Makoto
Popescu, Sorin Ștefan
Subin, Behnam
Feher, Marcel
Phan, Huong-Lan
Kirstein, Bettina
Vogler, Julia
Eitel, Charlotte
Hatahet, Sascha
Kuck, Karl-Heinz
Tilz, Roland R
author_facet Heeger, Christian-H
Sano, Makoto
Popescu, Sorin Ștefan
Subin, Behnam
Feher, Marcel
Phan, Huong-Lan
Kirstein, Bettina
Vogler, Julia
Eitel, Charlotte
Hatahet, Sascha
Kuck, Karl-Heinz
Tilz, Roland R
author_sort Heeger, Christian-H
collection PubMed
description AIMS: The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the ‘close protocol’ has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter ‘very-close protocol’ of 3–4 mm of inter-lesion distance (ILD) at the anterior and 5–6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. METHODS AND RESULTS: A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). CONCLUSIONS: PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.
format Online
Article
Text
id pubmed-10062369
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-100623692023-03-31 Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study Heeger, Christian-H Sano, Makoto Popescu, Sorin Ștefan Subin, Behnam Feher, Marcel Phan, Huong-Lan Kirstein, Bettina Vogler, Julia Eitel, Charlotte Hatahet, Sascha Kuck, Karl-Heinz Tilz, Roland R Europace Clinical Research AIMS: The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the ‘close protocol’ has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter ‘very-close protocol’ of 3–4 mm of inter-lesion distance (ILD) at the anterior and 5–6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. METHODS AND RESULTS: A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). CONCLUSIONS: PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising. Oxford University Press 2022-12-22 /pmc/articles/PMC10062369/ /pubmed/36546582 http://dx.doi.org/10.1093/europace/euac243 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Clinical Research
Heeger, Christian-H
Sano, Makoto
Popescu, Sorin Ștefan
Subin, Behnam
Feher, Marcel
Phan, Huong-Lan
Kirstein, Bettina
Vogler, Julia
Eitel, Charlotte
Hatahet, Sascha
Kuck, Karl-Heinz
Tilz, Roland R
Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study
title Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study
title_full Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study
title_fullStr Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study
title_full_unstemmed Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study
title_short Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the FAST AND FURIOUS PVI study
title_sort very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol—the fast and furious pvi study
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062369/
https://www.ncbi.nlm.nih.gov/pubmed/36546582
http://dx.doi.org/10.1093/europace/euac243
work_keys_str_mv AT heegerchristianh veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT sanomakoto veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT popescusorinstefan veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT subinbehnam veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT fehermarcel veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT phanhuonglan veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT kirsteinbettina veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT voglerjulia veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT eitelcharlotte veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT hatahetsascha veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT kuckkarlheinz veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy
AT tilzrolandr veryhighpowershortdurationablationforpulmonaryveinisolationutilizingaverycloseprotocolthefastandfuriouspvistudy