Cargando…

Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy

SIGNIFICANCE: Diffuse correlation spectroscopy (DCS) is an emerging optical modality for non-invasive assessment of an index of regional cerebral blood flow. By the nature of this noninvasive measurement, light must pass through extracerebral layers (i.e., skull, scalp, and cerebral spinal fluid) be...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Hongting, Buckley, Erin M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062384/
https://www.ncbi.nlm.nih.gov/pubmed/37006324
http://dx.doi.org/10.1117/1.NPh.10.1.015010
_version_ 1785017482237444096
author Zhao, Hongting
Buckley, Erin M.
author_facet Zhao, Hongting
Buckley, Erin M.
author_sort Zhao, Hongting
collection PubMed
description SIGNIFICANCE: Diffuse correlation spectroscopy (DCS) is an emerging optical modality for non-invasive assessment of an index of regional cerebral blood flow. By the nature of this noninvasive measurement, light must pass through extracerebral layers (i.e., skull, scalp, and cerebral spinal fluid) before detection at the tissue surface. To minimize the contribution of these extracerebral layers to the measured signal, an analytical model has been developed that treats the head as a series of three parallel and infinitely extending slabs (mimicking scalp, skull, and brain). The three-layer model has been shown to provide a significant improvement in cerebral blood flow estimation over the typically used model that treats the head as a bulk homogenous medium. However, the three-layer model is still a gross oversimplification of the head geometry that ignores head curvature, the presence of cerebrospinal fluid (CSF), and heterogeneity in layer thickness. AIM: Determine the influence of oversimplifying the head geometry on cerebral blood flow estimated with the three-layer model. APPROACH: Data were simulated with Monte Carlo in a four-layer slab medium and a three-layer sphere medium to isolate the influence of CSF and curvature, respectively. Additionally, simulations were performed on magnetic resonance imaging (MRI) head templates spanning a wide-range of ages. Simulated data were fit to both the homogenous and three-layer model for CBF. Finally, to mitigate the errors in potential CBF estimation due to the difficulty in defining layer thickness, we investigated an approach to identify an equivalent, “optimized” thickness via a pressure modulation. RESULTS: Both head curvature and failing to account for CSF lead to significant errors in the estimation of CBF. However, the effect of curvature and CSF on relative changes in CBF is minimal. Further, we found that CBF was underestimated in all MRI-templates, although the magnitude of these underestimations was highly influenced by small variations in the source and detector optode positioning. The optimized thickness obtained from pressure modulation did not improve estimation accuracy of CBF, although it did significantly improve the estimation accuracy of relative changes in CBF. CONCLUSIONS: In sum, these findings suggest that the three-layer model holds promise for improving estimation of relative changes in cerebral blood flow; however, estimations of absolute cerebral blood flow with the approach should be viewed with caution given that it is difficult to account for appreciable sources of error, such as curvature and CSF.
format Online
Article
Text
id pubmed-10062384
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-100623842023-03-31 Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy Zhao, Hongting Buckley, Erin M. Neurophotonics Research Papers SIGNIFICANCE: Diffuse correlation spectroscopy (DCS) is an emerging optical modality for non-invasive assessment of an index of regional cerebral blood flow. By the nature of this noninvasive measurement, light must pass through extracerebral layers (i.e., skull, scalp, and cerebral spinal fluid) before detection at the tissue surface. To minimize the contribution of these extracerebral layers to the measured signal, an analytical model has been developed that treats the head as a series of three parallel and infinitely extending slabs (mimicking scalp, skull, and brain). The three-layer model has been shown to provide a significant improvement in cerebral blood flow estimation over the typically used model that treats the head as a bulk homogenous medium. However, the three-layer model is still a gross oversimplification of the head geometry that ignores head curvature, the presence of cerebrospinal fluid (CSF), and heterogeneity in layer thickness. AIM: Determine the influence of oversimplifying the head geometry on cerebral blood flow estimated with the three-layer model. APPROACH: Data were simulated with Monte Carlo in a four-layer slab medium and a three-layer sphere medium to isolate the influence of CSF and curvature, respectively. Additionally, simulations were performed on magnetic resonance imaging (MRI) head templates spanning a wide-range of ages. Simulated data were fit to both the homogenous and three-layer model for CBF. Finally, to mitigate the errors in potential CBF estimation due to the difficulty in defining layer thickness, we investigated an approach to identify an equivalent, “optimized” thickness via a pressure modulation. RESULTS: Both head curvature and failing to account for CSF lead to significant errors in the estimation of CBF. However, the effect of curvature and CSF on relative changes in CBF is minimal. Further, we found that CBF was underestimated in all MRI-templates, although the magnitude of these underestimations was highly influenced by small variations in the source and detector optode positioning. The optimized thickness obtained from pressure modulation did not improve estimation accuracy of CBF, although it did significantly improve the estimation accuracy of relative changes in CBF. CONCLUSIONS: In sum, these findings suggest that the three-layer model holds promise for improving estimation of relative changes in cerebral blood flow; however, estimations of absolute cerebral blood flow with the approach should be viewed with caution given that it is difficult to account for appreciable sources of error, such as curvature and CSF. Society of Photo-Optical Instrumentation Engineers 2023-03-30 2023-01 /pmc/articles/PMC10062384/ /pubmed/37006324 http://dx.doi.org/10.1117/1.NPh.10.1.015010 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Research Papers
Zhao, Hongting
Buckley, Erin M.
Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
title Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
title_full Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
title_fullStr Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
title_full_unstemmed Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
title_short Influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
title_sort influence of oversimplifying the head anatomy on cerebral blood flow measurements with diffuse correlation spectroscopy
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10062384/
https://www.ncbi.nlm.nih.gov/pubmed/37006324
http://dx.doi.org/10.1117/1.NPh.10.1.015010
work_keys_str_mv AT zhaohongting influenceofoversimplifyingtheheadanatomyoncerebralbloodflowmeasurementswithdiffusecorrelationspectroscopy
AT buckleyerinm influenceofoversimplifyingtheheadanatomyoncerebralbloodflowmeasurementswithdiffusecorrelationspectroscopy