Cargando…
Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures
PURPOSE: To assess the reproducibility of a new 2-dimensional computed tomography (CT) method of assessing graft positioning in arthroscopic bone block procedure. METHODS: This is a prospective observational study. Twenty-seven patients, (all men, mean [Standard deviation] age at surgery 30.9 [8.49]...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10063754/ https://www.ncbi.nlm.nih.gov/pubmed/36995539 http://dx.doi.org/10.1186/s40634-023-00590-3 |
_version_ | 1785017763655319552 |
---|---|
author | Delgado, Cristina De Rus, Ignacio Cañete, Pablo Díaz, Jorge Ruiz, Raquel García Navlet, Miguel Ruiz Ibán, Miguel Ángel |
author_facet | Delgado, Cristina De Rus, Ignacio Cañete, Pablo Díaz, Jorge Ruiz, Raquel García Navlet, Miguel Ruiz Ibán, Miguel Ángel |
author_sort | Delgado, Cristina |
collection | PubMed |
description | PURPOSE: To assess the reproducibility of a new 2-dimensional computed tomography (CT) method of assessing graft positioning in arthroscopic bone block procedure. METHODS: This is a prospective observational study. Twenty-seven patients, (all men, mean [Standard deviation] age at surgery 30.9 [8.49] years) were included. Vertical graft position was assessed on the sagittal view by measuring the amount of glenoid bone defect covered by the graft. The length of the bone defect and the amount of graft covering the defect were measured. Positioning of the graft on the sagittal plane was classified as accurate if the graft covered at least 90% of the defect. Intraobserver and interobserver reproducibility was analyzed using intraclass correlation coefficients (ICC) and Kappa coefficient with 95% confidence. RESULTS: Excellent intraobserver reproducibility was found, with an ICC of 0.94 (CI 95%, 0.86-0.97). Interobserver reproducibility was good, with the ICC value of 0.71, ranging from 0.45 to 0.86 (CI 95%). CONCLUSION: This new method of assessing graft positioning in arthroscopic bone block procedures on 2-dimensional computed tomography scans is reliable, with an excellent intraobserver and good interobserver reproducibility. LEVEL OF EVIDENCE: III |
format | Online Article Text |
id | pubmed-10063754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-100637542023-04-01 Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures Delgado, Cristina De Rus, Ignacio Cañete, Pablo Díaz, Jorge Ruiz, Raquel García Navlet, Miguel Ruiz Ibán, Miguel Ángel J Exp Orthop Original Paper PURPOSE: To assess the reproducibility of a new 2-dimensional computed tomography (CT) method of assessing graft positioning in arthroscopic bone block procedure. METHODS: This is a prospective observational study. Twenty-seven patients, (all men, mean [Standard deviation] age at surgery 30.9 [8.49] years) were included. Vertical graft position was assessed on the sagittal view by measuring the amount of glenoid bone defect covered by the graft. The length of the bone defect and the amount of graft covering the defect were measured. Positioning of the graft on the sagittal plane was classified as accurate if the graft covered at least 90% of the defect. Intraobserver and interobserver reproducibility was analyzed using intraclass correlation coefficients (ICC) and Kappa coefficient with 95% confidence. RESULTS: Excellent intraobserver reproducibility was found, with an ICC of 0.94 (CI 95%, 0.86-0.97). Interobserver reproducibility was good, with the ICC value of 0.71, ranging from 0.45 to 0.86 (CI 95%). CONCLUSION: This new method of assessing graft positioning in arthroscopic bone block procedures on 2-dimensional computed tomography scans is reliable, with an excellent intraobserver and good interobserver reproducibility. LEVEL OF EVIDENCE: III Springer Berlin Heidelberg 2023-03-30 /pmc/articles/PMC10063754/ /pubmed/36995539 http://dx.doi.org/10.1186/s40634-023-00590-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Delgado, Cristina De Rus, Ignacio Cañete, Pablo Díaz, Jorge Ruiz, Raquel García Navlet, Miguel Ruiz Ibán, Miguel Ángel Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
title | Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
title_full | Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
title_fullStr | Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
title_full_unstemmed | Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
title_short | Evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
title_sort | evaluation of the inter and intraobserver reproducibility of the “defect coverage index method”, a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10063754/ https://www.ncbi.nlm.nih.gov/pubmed/36995539 http://dx.doi.org/10.1186/s40634-023-00590-3 |
work_keys_str_mv | AT delgadocristina evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures AT derusignacio evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures AT canetepablo evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures AT diazjorge evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures AT ruizraquel evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures AT garcianavletmiguel evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures AT ruizibanmiguelangel evaluationoftheinterandintraobserverreproducibilityofthedefectcoverageindexmethodanewcomputedtomographyassessmentmethodofsagittalgraftpositioninginarthroscopicboneblockprocedures |