Cargando…
Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
Emergency surgery was performed to treat acute lower limb ischemia caused by heart thromboembolism and concomitant popliteal artery aneurysm. Using a near-infrared spectroscopy oximeter, regional tissue oxygen saturation (rSO(2)) was monitored to assess the tissue perfusion pre-, intra-, and postope...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064307/ https://www.ncbi.nlm.nih.gov/pubmed/37006860 http://dx.doi.org/10.3400/avd.cr.22-00062 |
_version_ | 1785017873567055872 |
---|---|
author | Yata, Tatsuro Sano, Masaki Inuzuka, Kazunori Katahashi, Kazuto Naruse, Ena Kayama, Takafumi Yamanaka, Yuta Tsuyuki, Hajime Endo, Yusuke Ishikawa, Nozomu Takeuchi, Hiroya Unno, Naoki |
author_facet | Yata, Tatsuro Sano, Masaki Inuzuka, Kazunori Katahashi, Kazuto Naruse, Ena Kayama, Takafumi Yamanaka, Yuta Tsuyuki, Hajime Endo, Yusuke Ishikawa, Nozomu Takeuchi, Hiroya Unno, Naoki |
author_sort | Yata, Tatsuro |
collection | PubMed |
description | Emergency surgery was performed to treat acute lower limb ischemia caused by heart thromboembolism and concomitant popliteal artery aneurysm. Using a near-infrared spectroscopy oximeter, regional tissue oxygen saturation (rSO(2)) was monitored to assess the tissue perfusion pre-, intra-, and postoperatively. rSO(2) values did not increase sufficiently following thromboembolectomy of the superficial femoral artery, but they dramatically recovered after additional popliteal-anterior tibial bypass surgery. The affected limb was successfully salvaged. rSO(2) monitoring was easily measured intraoperatively, which might be beneficial in evaluating tissue perfusion in patients with acute limb ischemia. |
format | Online Article Text |
id | pubmed-10064307 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology |
record_format | MEDLINE/PubMed |
spelling | pubmed-100643072023-04-01 Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report Yata, Tatsuro Sano, Masaki Inuzuka, Kazunori Katahashi, Kazuto Naruse, Ena Kayama, Takafumi Yamanaka, Yuta Tsuyuki, Hajime Endo, Yusuke Ishikawa, Nozomu Takeuchi, Hiroya Unno, Naoki Ann Vasc Dis Case Report Emergency surgery was performed to treat acute lower limb ischemia caused by heart thromboembolism and concomitant popliteal artery aneurysm. Using a near-infrared spectroscopy oximeter, regional tissue oxygen saturation (rSO(2)) was monitored to assess the tissue perfusion pre-, intra-, and postoperatively. rSO(2) values did not increase sufficiently following thromboembolectomy of the superficial femoral artery, but they dramatically recovered after additional popliteal-anterior tibial bypass surgery. The affected limb was successfully salvaged. rSO(2) monitoring was easily measured intraoperatively, which might be beneficial in evaluating tissue perfusion in patients with acute limb ischemia. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2023-03-25 /pmc/articles/PMC10064307/ /pubmed/37006860 http://dx.doi.org/10.3400/avd.cr.22-00062 Text en © 2023 The Editorial Committee of Annals of Vascular Diseases. https://creativecommons.org/licenses/by-nc-sa/4.0/This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original. |
spellingShingle | Case Report Yata, Tatsuro Sano, Masaki Inuzuka, Kazunori Katahashi, Kazuto Naruse, Ena Kayama, Takafumi Yamanaka, Yuta Tsuyuki, Hajime Endo, Yusuke Ishikawa, Nozomu Takeuchi, Hiroya Unno, Naoki Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report |
title | Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report |
title_full | Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report |
title_fullStr | Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report |
title_full_unstemmed | Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report |
title_short | Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report |
title_sort | real-time assessment of tissue oxygen saturation using a novel oximeter during revascularization for acute limb ischemia: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064307/ https://www.ncbi.nlm.nih.gov/pubmed/37006860 http://dx.doi.org/10.3400/avd.cr.22-00062 |
work_keys_str_mv | AT yatatatsuro realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT sanomasaki realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT inuzukakazunori realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT katahashikazuto realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT naruseena realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT kayamatakafumi realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT yamanakayuta realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT tsuyukihajime realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT endoyusuke realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT ishikawanozomu realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT takeuchihiroya realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport AT unnonaoki realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport |