Cargando…

Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report

Emergency surgery was performed to treat acute lower limb ischemia caused by heart thromboembolism and concomitant popliteal artery aneurysm. Using a near-infrared spectroscopy oximeter, regional tissue oxygen saturation (rSO(2)) was monitored to assess the tissue perfusion pre-, intra-, and postope...

Descripción completa

Detalles Bibliográficos
Autores principales: Yata, Tatsuro, Sano, Masaki, Inuzuka, Kazunori, Katahashi, Kazuto, Naruse, Ena, Kayama, Takafumi, Yamanaka, Yuta, Tsuyuki, Hajime, Endo, Yusuke, Ishikawa, Nozomu, Takeuchi, Hiroya, Unno, Naoki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064307/
https://www.ncbi.nlm.nih.gov/pubmed/37006860
http://dx.doi.org/10.3400/avd.cr.22-00062
_version_ 1785017873567055872
author Yata, Tatsuro
Sano, Masaki
Inuzuka, Kazunori
Katahashi, Kazuto
Naruse, Ena
Kayama, Takafumi
Yamanaka, Yuta
Tsuyuki, Hajime
Endo, Yusuke
Ishikawa, Nozomu
Takeuchi, Hiroya
Unno, Naoki
author_facet Yata, Tatsuro
Sano, Masaki
Inuzuka, Kazunori
Katahashi, Kazuto
Naruse, Ena
Kayama, Takafumi
Yamanaka, Yuta
Tsuyuki, Hajime
Endo, Yusuke
Ishikawa, Nozomu
Takeuchi, Hiroya
Unno, Naoki
author_sort Yata, Tatsuro
collection PubMed
description Emergency surgery was performed to treat acute lower limb ischemia caused by heart thromboembolism and concomitant popliteal artery aneurysm. Using a near-infrared spectroscopy oximeter, regional tissue oxygen saturation (rSO(2)) was monitored to assess the tissue perfusion pre-, intra-, and postoperatively. rSO(2) values did not increase sufficiently following thromboembolectomy of the superficial femoral artery, but they dramatically recovered after additional popliteal-anterior tibial bypass surgery. The affected limb was successfully salvaged. rSO(2) monitoring was easily measured intraoperatively, which might be beneficial in evaluating tissue perfusion in patients with acute limb ischemia.
format Online
Article
Text
id pubmed-10064307
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
record_format MEDLINE/PubMed
spelling pubmed-100643072023-04-01 Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report Yata, Tatsuro Sano, Masaki Inuzuka, Kazunori Katahashi, Kazuto Naruse, Ena Kayama, Takafumi Yamanaka, Yuta Tsuyuki, Hajime Endo, Yusuke Ishikawa, Nozomu Takeuchi, Hiroya Unno, Naoki Ann Vasc Dis Case Report Emergency surgery was performed to treat acute lower limb ischemia caused by heart thromboembolism and concomitant popliteal artery aneurysm. Using a near-infrared spectroscopy oximeter, regional tissue oxygen saturation (rSO(2)) was monitored to assess the tissue perfusion pre-, intra-, and postoperatively. rSO(2) values did not increase sufficiently following thromboembolectomy of the superficial femoral artery, but they dramatically recovered after additional popliteal-anterior tibial bypass surgery. The affected limb was successfully salvaged. rSO(2) monitoring was easily measured intraoperatively, which might be beneficial in evaluating tissue perfusion in patients with acute limb ischemia. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2023-03-25 /pmc/articles/PMC10064307/ /pubmed/37006860 http://dx.doi.org/10.3400/avd.cr.22-00062 Text en © 2023 The Editorial Committee of Annals of Vascular Diseases. https://creativecommons.org/licenses/by-nc-sa/4.0/This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.
spellingShingle Case Report
Yata, Tatsuro
Sano, Masaki
Inuzuka, Kazunori
Katahashi, Kazuto
Naruse, Ena
Kayama, Takafumi
Yamanaka, Yuta
Tsuyuki, Hajime
Endo, Yusuke
Ishikawa, Nozomu
Takeuchi, Hiroya
Unno, Naoki
Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
title Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
title_full Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
title_fullStr Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
title_full_unstemmed Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
title_short Real-Time Assessment of Tissue Oxygen Saturation Using a Novel Oximeter During Revascularization for Acute Limb Ischemia: A Case Report
title_sort real-time assessment of tissue oxygen saturation using a novel oximeter during revascularization for acute limb ischemia: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064307/
https://www.ncbi.nlm.nih.gov/pubmed/37006860
http://dx.doi.org/10.3400/avd.cr.22-00062
work_keys_str_mv AT yatatatsuro realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT sanomasaki realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT inuzukakazunori realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT katahashikazuto realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT naruseena realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT kayamatakafumi realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT yamanakayuta realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT tsuyukihajime realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT endoyusuke realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT ishikawanozomu realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT takeuchihiroya realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport
AT unnonaoki realtimeassessmentoftissueoxygensaturationusinganoveloximeterduringrevascularizationforacutelimbischemiaacasereport