Cargando…

Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study

BACKGROUND: In implant prosthetic dentistry, the adhesive connection of individualized ceramic crowns and prefabricated titanium bases leads to several benefits. However, the durability of the bonding could be a weak point and especially depends on sufficient surface pretreatment. Cold atmospheric-p...

Descripción completa

Detalles Bibliográficos
Autores principales: Görgen, Carolin-Isabel, Sagheb, Kawe, Lehmann, Karl Martin, Schmidtmann, Irene, Wentaschek, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064688/
https://www.ncbi.nlm.nih.gov/pubmed/36997908
http://dx.doi.org/10.1186/s12903-023-02880-9
_version_ 1785017950474862592
author Görgen, Carolin-Isabel
Sagheb, Kawe
Lehmann, Karl Martin
Schmidtmann, Irene
Wentaschek, Stefan
author_facet Görgen, Carolin-Isabel
Sagheb, Kawe
Lehmann, Karl Martin
Schmidtmann, Irene
Wentaschek, Stefan
author_sort Görgen, Carolin-Isabel
collection PubMed
description BACKGROUND: In implant prosthetic dentistry, the adhesive connection of individualized ceramic crowns and prefabricated titanium bases leads to several benefits. However, the durability of the bonding could be a weak point and especially depends on sufficient surface pretreatment. Cold atmospheric-pressure plasma (CAP) is a pretreatment method that should improve the surface properties without physical damage. Thus, the purpose of this study was to investigate the influence of CAP treatment on pull-off tensile load in two-piece abutment crowns. METHODS: Eighty zirconia crowns and titanium bases were divided into eight groups (n = 10) according to their surface pretreatment prior to cementation with Panavia V5: no treatment (A); sandblasting (B); 10-MDP primer (C); sandblasting and primer (D); CAP (AP); sandblasting and CAP (BP); CAP and primer (CP); sandblasting, CAP and primer (DP). The specimens were thermocycled (5°/55°, 5000 cycles), and then the pull-off tensile load (TL) was measured. Statistical analyses were performed using three-way ANOVA with Tukey post-hoc and Fisher’s exact tests. RESULTS: The results showed that the TL was highest in group D (p < 0.0001). Some combinations of different treatments led to effects that were greater than the sum of the individual effects. These effects were modified by interactions. Only in combination with primer, CAP treatment had a small but positive significant effect (group CP vs. C and CP vs. AP, p < 0.0001) which however did not come close to the strong interaction effect that resulted from the combination of sandblasting and primer. CONCLUSION: Within the limitations of this study, CAP treatment cannot be recommended in this specific field of indication due to its unreliable influence on TL in combination with other pretreatment methods.
format Online
Article
Text
id pubmed-10064688
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-100646882023-04-01 Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study Görgen, Carolin-Isabel Sagheb, Kawe Lehmann, Karl Martin Schmidtmann, Irene Wentaschek, Stefan BMC Oral Health Research BACKGROUND: In implant prosthetic dentistry, the adhesive connection of individualized ceramic crowns and prefabricated titanium bases leads to several benefits. However, the durability of the bonding could be a weak point and especially depends on sufficient surface pretreatment. Cold atmospheric-pressure plasma (CAP) is a pretreatment method that should improve the surface properties without physical damage. Thus, the purpose of this study was to investigate the influence of CAP treatment on pull-off tensile load in two-piece abutment crowns. METHODS: Eighty zirconia crowns and titanium bases were divided into eight groups (n = 10) according to their surface pretreatment prior to cementation with Panavia V5: no treatment (A); sandblasting (B); 10-MDP primer (C); sandblasting and primer (D); CAP (AP); sandblasting and CAP (BP); CAP and primer (CP); sandblasting, CAP and primer (DP). The specimens were thermocycled (5°/55°, 5000 cycles), and then the pull-off tensile load (TL) was measured. Statistical analyses were performed using three-way ANOVA with Tukey post-hoc and Fisher’s exact tests. RESULTS: The results showed that the TL was highest in group D (p < 0.0001). Some combinations of different treatments led to effects that were greater than the sum of the individual effects. These effects were modified by interactions. Only in combination with primer, CAP treatment had a small but positive significant effect (group CP vs. C and CP vs. AP, p < 0.0001) which however did not come close to the strong interaction effect that resulted from the combination of sandblasting and primer. CONCLUSION: Within the limitations of this study, CAP treatment cannot be recommended in this specific field of indication due to its unreliable influence on TL in combination with other pretreatment methods. BioMed Central 2023-03-30 /pmc/articles/PMC10064688/ /pubmed/36997908 http://dx.doi.org/10.1186/s12903-023-02880-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Görgen, Carolin-Isabel
Sagheb, Kawe
Lehmann, Karl Martin
Schmidtmann, Irene
Wentaschek, Stefan
Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
title Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
title_full Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
title_fullStr Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
title_full_unstemmed Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
title_short Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
title_sort influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns: an in-vitro study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10064688/
https://www.ncbi.nlm.nih.gov/pubmed/36997908
http://dx.doi.org/10.1186/s12903-023-02880-9
work_keys_str_mv AT gorgencarolinisabel influenceofcoldatmosphericpressureplasmaincombinationwithdifferentpretreatmentmethodsonthepullofftensileloadintwopieceabutmentcrownsaninvitrostudy
AT saghebkawe influenceofcoldatmosphericpressureplasmaincombinationwithdifferentpretreatmentmethodsonthepullofftensileloadintwopieceabutmentcrownsaninvitrostudy
AT lehmannkarlmartin influenceofcoldatmosphericpressureplasmaincombinationwithdifferentpretreatmentmethodsonthepullofftensileloadintwopieceabutmentcrownsaninvitrostudy
AT schmidtmannirene influenceofcoldatmosphericpressureplasmaincombinationwithdifferentpretreatmentmethodsonthepullofftensileloadintwopieceabutmentcrownsaninvitrostudy
AT wentaschekstefan influenceofcoldatmosphericpressureplasmaincombinationwithdifferentpretreatmentmethodsonthepullofftensileloadintwopieceabutmentcrownsaninvitrostudy